These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
128 related articles for article (PubMed ID: 32694465)
1. Assessing Postvoid Residual to Identify Risk for Urinary Complications Post Stroke. Smith CE; Schneider MA J Neurosci Nurs; 2020 Oct; 52(5):219-223. PubMed ID: 32694465 [TBL] [Abstract][Full Text] [Related]
2. The utility of a bladder scan protocol using a portable ultrasonographic device in subacute stroke patients. Kim HJ; Chun MH; Han EY; Yi JH; Kim DK Disabil Rehabil; 2012; 34(6):486-90. PubMed ID: 22087731 [TBL] [Abstract][Full Text] [Related]
3. The accuracy of portable abdominal ultrasound equipment in measuring postvoid residual volume. Alnaif B; Drutz HP Int Urogynecol J Pelvic Floor Dysfunct; 1999; 10(4):215-8. PubMed ID: 10450819 [TBL] [Abstract][Full Text] [Related]
4. Portable Bladder Ultrasound Reduces Incidence of Urinary Tract Infection and Shortens Hospital Length of Stay in Patients With Acute Ischemic Stroke. Chen SC; Chen PY; Chen GC; Chuang SY; Tzeng IS; Lin SK J Cardiovasc Nurs; 2018; 33(6):551-558. PubMed ID: 29851660 [TBL] [Abstract][Full Text] [Related]
5. Accuracy of Post-Void Residual Urine Volume Measurement Using an Ultrasound Bladder Scanner among Postoperative Radical Hysterectomy Patients. Thanagumtorn K J Med Assoc Thai; 2016 Oct; 99(10):1061-6. PubMed ID: 29952185 [TBL] [Abstract][Full Text] [Related]
6. Does this man with lower urinary tract symptoms have bladder outlet obstruction?: The Rational Clinical Examination: a systematic review. D'Silva KA; Dahm P; Wong CL JAMA; 2014 Aug; 312(5):535-42. PubMed ID: 25096693 [TBL] [Abstract][Full Text] [Related]
7. Improving Postoperative Efficiency: An Algorithm for Expedited Void Trials After Urogynecologic Surgery. Meekins AR; Siddiqui NY; Amundsen CL; Kuchibhatla M; Dieter AA South Med J; 2017 Dec; 110(12):785-790. PubMed ID: 29197314 [TBL] [Abstract][Full Text] [Related]
8. [Use in daily urological practice of an ultrasound device for measuring bladder volume]. Roupret M; Chartier-Kastler E; Hopirtean V; Barret E; Haertig A; Richard F Presse Med; 2003 May; 32(17):776-80. PubMed ID: 12856322 [TBL] [Abstract][Full Text] [Related]
9. Accuracy of post-void residual urine volume measurement using a portable ultrasound bladder scanner with real-time pre-scan imaging. Park YH; Ku JH; Oh SJ Neurourol Urodyn; 2011 Mar; 30(3):335-8. PubMed ID: 20658544 [TBL] [Abstract][Full Text] [Related]
10. Can we define the optimal postvoid residual volume at which intermittent catheterization should be recommended, and are there other measures that could guide an intermittent catheterization protocol: ICI-RS 2023. Malde S; Belal M; Mohamed-Ahmed R; Gibson W; Padilla-Fernandez B; Rantell A; Selai C; Solomon E; Abrams P Neurourol Urodyn; 2024 Aug; 43(6):1353-1362. PubMed ID: 37905437 [TBL] [Abstract][Full Text] [Related]
11. Feasibility of approximate measurement of bladder volume in male patients using the Lilium α-200 portable ultrasound bladder scanner. Kamei J; Watanabe D; Homma Y; Kume H; Igawa Y Low Urin Tract Symptoms; 2019 May; 11(3):169-173. PubMed ID: 30854772 [TBL] [Abstract][Full Text] [Related]
12. Measurement of postvoid residual urine with portable transabdominal bladder ultrasound scanner and urethral catheterization. Goode PS; Locher JL; Bryant RL; Roth DL; Burgio KL Int Urogynecol J Pelvic Floor Dysfunct; 2000; 11(5):296-300. PubMed ID: 11052565 [TBL] [Abstract][Full Text] [Related]
13. Accuracy of Bladder Scanner for the Assessment of Postvoid Residual Volumes in Women With Pelvic Organ Prolapse. Taylor DL; Sierra T; Duenas-Garcia OF; Kim Y; Leung K; Hall C; Flynn MK Female Pelvic Med Reconstr Surg; 2020 Oct; 26(10):640-643. PubMed ID: 30325783 [TBL] [Abstract][Full Text] [Related]
14. Can we replace the catheter when evaluating urinary residuals? Araklitis G; Paganotto M; Hunter J; Thiagamoorthy G; Robinson D; Cardozo L Neurourol Urodyn; 2019 Apr; 38(4):1100-1105. PubMed ID: 30843290 [TBL] [Abstract][Full Text] [Related]
15. Relation of postvoid residual to urinary tract infection during stroke rehabilitation. Dromerick AW; Edwards DF Arch Phys Med Rehabil; 2003 Sep; 84(9):1369-72. PubMed ID: 13680576 [TBL] [Abstract][Full Text] [Related]
17. The use of an ultrasound bladder scanning device in women undergoing urogynaecologic surgery. Fedorkow DM; Dore S; Cotton A J Obstet Gynaecol Can; 2005 Oct; 27(10):945-8. PubMed ID: 16411009 [TBL] [Abstract][Full Text] [Related]
18. Post-void residual urine ratio: A novel clinical approach to the post-void residual urine in the assessment of males with lower urinary tract symptoms. Rubilotta E; Balzarro M; Trabacchin N; Righetti R; D'Amico A; Blaivas JG; Antonelli A Investig Clin Urol; 2021 Jul; 62(4):470-476. PubMed ID: 34085789 [TBL] [Abstract][Full Text] [Related]
19. Cystic pelvic pathology presenting as falsely elevated post-void residual urine measured by portable ultrasound bladder scanning: report of 3 cases and review of the literature. Cooperberg MR; Chambers SK; Rutherford TJ; Foster HE Urology; 2000 Apr; 55(4):590. PubMed ID: 10754180 [TBL] [Abstract][Full Text] [Related]
20. Diagnosis of Postoperative Urinary Retention Using a Simplified Ultrasound Bladder Measurement. Daurat A; Choquet O; Bringuier S; Charbit J; Egan M; Capdevila X Anesth Analg; 2015 May; 120(5):1033-1038. PubMed ID: 25642660 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]