These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
227 related articles for article (PubMed ID: 32702008)
1. Pragmatic accuracy of an in-house loop-mediated isothermal amplification (LAMP) for diagnosis of pulmonary tuberculosis in a Thai community hospital. Toonkomdang S; Phinyo P; Phetsuksiri B; Patumanond J; Rudeeaneksin J; Klayut W PLoS One; 2020; 15(7):e0236496. PubMed ID: 32702008 [TBL] [Abstract][Full Text] [Related]
2. Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis. Gelaw B; Shiferaw Y; Alemayehu M; Bashaw AA BMC Infect Dis; 2017 Jan; 17(1):79. PubMed ID: 28095790 [TBL] [Abstract][Full Text] [Related]
3. Comparison of Loop-Mediated Isothermal Amplification, Microscopy, Culture, and PCR for Diagnosis of Pulmonary Tuberculosis. Phetsuksiri B; Rudeeaneksin J; Srisungngam S; Bunchoo S; Klayut W; Nakajima C; Hamada S; Suzuki Y Jpn J Infect Dis; 2020 Jul; 73(4):272-277. PubMed ID: 32115540 [TBL] [Abstract][Full Text] [Related]
4. The performance of an in-house loop-mediated isothermal amplification for the rapid detection of Mycobacterium tuberculosis in sputum samples in comparison with Xpert MTB/RIF, microscopy and culture. Phetsuksiri B; Klayut W; Rudeeaneksin J; Srisungngam S; Bunchoo S; Toonkomdang S; Wongchai T; Nakajima C; Suzuki Y Rev Inst Med Trop Sao Paulo; 2020; 62():e36. PubMed ID: 32520211 [TBL] [Abstract][Full Text] [Related]
5. Rapid laboratory diagnosis of pulmonary tuberculosis. Bhirud P; Joshi A; Hirani N; Chowdhary A Int J Mycobacteriol; 2017; 6(3):296-301. PubMed ID: 28776530 [TBL] [Abstract][Full Text] [Related]
6. Clinical profiling and use of loop-mediated isothermal amplification assay for rapid detection of Mycobacterium tuberculosis from sputum. Poudel A; Pandey BD; Lekhak B; Rijal B; Sapkota BR; Suzuki Y Kathmandu Univ Med J (KUMJ); 2009; 7(26):109-14. PubMed ID: 20071841 [TBL] [Abstract][Full Text] [Related]
7. Performance of loop-mediated isothermal amplification assay in the diagnosis of pulmonary tuberculosis in a high prevalence TB/HIV rural setting in Uganda. Nakiyingi L; Nakanwagi P; Briggs J; Agaba T; Mubiru F; Mugenyi M; Ssengooba W; Joloba ML; Manabe YC BMC Infect Dis; 2018 Feb; 18(1):87. PubMed ID: 29466946 [TBL] [Abstract][Full Text] [Related]
8. Comparison of Diagnostic Yield of Tuberculosis Loop-Mediated Isothermal Amplification Assay With Cartridge-Based Nucleic Acid Amplification Test, Acid-Fast Bacilli Microscopy, and Mycobacteria Growth Indicator Tube Culture in Children With Pulmonary Tuberculosis. Dayal R; Yadav A; Agarwal D; Kumar M; Kamal R; Singh D; Bhatnagar S J Pediatric Infect Dis Soc; 2021 Mar; 10(2):83-87. PubMed ID: 32154870 [TBL] [Abstract][Full Text] [Related]
9. Evaluation of in-house loop-mediated isothermal amplification (LAMP) assay for rapid diagnosis of M. tuberculosis in pulmonary specimens. Sethi S; Singh S; Dhatwalia SK; Yadav R; Mewara A; Singh M; Tewari R; Sharma M J Clin Lab Anal; 2013 Jul; 27(4):272-6. PubMed ID: 23852783 [TBL] [Abstract][Full Text] [Related]
10. Diagnostic accuracy of the PURE-LAMP test for pulmonary tuberculosis at the county-level laboratory in China. Ou X; Li Q; Xia H; Pang Y; Wang S; Zhao B; Song Y; Zhou Y; Zheng Y; Zhang Z; Zhang Z; Li J; Dong H; Zhang J; Kam KM; Chi J; Huan S; Chin DP; Zhao Y PLoS One; 2014; 9(5):e94544. PubMed ID: 24788724 [TBL] [Abstract][Full Text] [Related]
11. Loop-mediated isothermal amplification (LAMP) in the respiratory specimens for the diagnosis of pediatric pulmonary tuberculosis: A pilot study. Sreedeep KS; Sethi S; Yadav R; Vaidya PC; Angurana SK; Saini A; Mehra N; Singh M J Infect Chemother; 2020 Aug; 26(8):823-830. PubMed ID: 32409020 [TBL] [Abstract][Full Text] [Related]
12. Diagnostic accuracy of TB-LAMP for pulmonary tuberculosis: a systematic review and meta-analysis. Shete PB; Farr K; Strnad L; Gray CM; Cattamanchi A BMC Infect Dis; 2019 Mar; 19(1):268. PubMed ID: 30890135 [TBL] [Abstract][Full Text] [Related]
13. Clinical diagnostic performance of the simultaneous amplification and testing methods for detection of the Mycobacterium tuberculosis complex for smear-negative or sputum-scarce pulmonary tuberculosis in China. Fan L; Zhang Q; Cheng L; Liu Z; Ji X; Cui Z; Ju J; Xiao H Chin Med J (Engl); 2014; 127(10):1863-7. PubMed ID: 24824246 [TBL] [Abstract][Full Text] [Related]
14. The Role of TB-LAMP Method in Detecting Mycobacterium tuberculosis from Sputum of Patients Suspected of Having Pulmonary Tuberculosis. Wahid MH; Sjahrurachman A; Sitorus AH; Burhan E Acta Med Indones; 2020 Oct; 52(4):352-359. PubMed ID: 33377880 [TBL] [Abstract][Full Text] [Related]
16. Detection of Mycobacterium tuberculosis complex in sputum specimens using a loop-mediated isothermal amplification assay in Korea. Moon SH; Kim EJ; Tomono J; Miyamoto S; Mitarai S; Kim DW; Seki M J Med Microbiol; 2015 Nov; 64(11):1335-1340. PubMed ID: 26338293 [TBL] [Abstract][Full Text] [Related]