These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 32703785)

  • 1. Different effect of media opacity on automated and manual measurement of foveal avascular zone of optical coherence tomography angiographies.
    Zhang J; Tang FY; Cheung C; Chen X; Chen H
    Br J Ophthalmol; 2021 Jun; 105(6):812-818. PubMed ID: 32703785
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reliability of foveal avascular zone metrics automatically measured by Cirrus optical coherence tomography angiography in healthy subjects.
    Lin A; Fang D; Li C; Cheung CY; Chen H
    Int Ophthalmol; 2020 Mar; 40(3):763-773. PubMed ID: 31792852
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Different Effect of Media Opacity on Vessel Density Measured by Different Optical Coherence Tomography Angiography Algorithms.
    Zhang J; Tang FY; Cheung CY; Chen H
    Transl Vis Sci Technol; 2020 Jul; 9(8):19. PubMed ID: 32855866
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved Automated Foveal Avascular Zone Measurement in Cirrus Optical Coherence Tomography Angiography Using the Level Sets Macro.
    Lin A; Fang D; Li C; Cheung CY; Chen H
    Transl Vis Sci Technol; 2020 Nov; 9(12):20. PubMed ID: 33240573
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of Automatically Quantified Foveal Avascular Zone Metrics for Diagnosis of Diabetic Retinopathy Using Optical Coherence Tomography Angiography.
    Lu Y; Simonett JM; Wang J; Zhang M; Hwang T; Hagag AM; Huang D; Li D; Jia Y
    Invest Ophthalmol Vis Sci; 2018 May; 59(6):2212-2221. PubMed ID: 29715365
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optical coherence tomography angiography analysis of foveal microvascular changes and inner retinal layer thinning in patients with diabetes.
    Kim K; Kim ES; Yu SY
    Br J Ophthalmol; 2018 Sep; 102(9):1226-1231. PubMed ID: 29259019
    [TBL] [Abstract][Full Text] [Related]  

  • 7. VARIABILITY IN FOVEAL AVASCULAR ZONE AND CAPILLARY DENSITY USING OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY MACHINES IN HEALTHY EYES.
    Magrath GN; Say EAT; Sioufi K; Ferenczy S; Samara WA; Shields CL
    Retina; 2017 Nov; 37(11):2102-2111. PubMed ID: 27997512
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Repeatability of Manual Measurement of Foveal Avascular Zone Area in Optical Coherence Tomography Angiography Images in High Myopia.
    Lee JH; Lee MW; Baek SK; Lee YH
    Korean J Ophthalmol; 2020 Apr; 34(2):113-120. PubMed ID: 32233144
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Comparison Between Automated and Manual Measurement of Foveal Avascular Zone Retinopathy in Optical Coherence Tomography].
    Enders C; Baeurle F; Lang GE; Dreyhaupt J; Trick S; Lang GK; Werner JU
    Klin Monbl Augenheilkd; 2019 Dec; 236(12):1445-1450. PubMed ID: 31671461
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Normative Data Assessment of Vessel Density and Foveal Avascular Zone Metrics Using AngioScan Software.
    Yilmaz H; Karakurt Y; Icel E; Ugurlu A; Ucak T; Tasli NG; Elpeze SB
    Curr Eye Res; 2019 Dec; 44(12):1345-1352. PubMed ID: 31280609
    [No Abstract]   [Full Text] [Related]  

  • 11. Direct and crossover effects of Phenylephrine and Cyclopentolate on foveal avascular zone and vessel density of macular capillary plexuses: an optical coherence tomography angiography study.
    Göker YŞ; Kızıltoprak H; Tekin K; Yetkin E; Karatepe MS; Özdemir K; Demir G
    Rom J Ophthalmol; 2020; 64(2):195-204. PubMed ID: 32685787
    [No Abstract]   [Full Text] [Related]  

  • 12. Foveal avascular zone and macular vessel density after correction for magnification error in unilateral amblyopia using optical coherence tomography angiography.
    Araki S; Miki A; Goto K; Yamashita T; Yoneda T; Haruishi K; Ieki Y; Kiryu J; Maehara G; Yaoeda K
    BMC Ophthalmol; 2019 Aug; 19(1):171. PubMed ID: 31382925
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Repeatability, interocular correlation and agreement of quantitative swept-source optical coherence tomography angiography macular metrics in healthy subjects.
    Fang D; Tang FY; Huang H; Cheung CY; Chen H
    Br J Ophthalmol; 2019 Mar; 103(3):415-420. PubMed ID: 29844088
    [TBL] [Abstract][Full Text] [Related]  

  • 14. REPRODUCIBILITY AND RELIABILITY OF OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY FOR FOVEAL AVASCULAR ZONE EVALUATION AND MEASUREMENT IN DIFFERENT SETTINGS.
    La Spina C; Carnevali A; Marchese A; Querques G; Bandello F
    Retina; 2017 Sep; 37(9):1636-1641. PubMed ID: 28002271
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Alterations of the Foveal Avascular Zone Measured by Optical Coherence Tomography Angiography in Glaucoma Patients With Central Visual Field Defects.
    Kwon J; Choi J; Shin JW; Lee J; Kook MS
    Invest Ophthalmol Vis Sci; 2017 Mar; 58(3):1637-1645. PubMed ID: 28297029
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reproducibility of Foveal Avascular Zone and Superficial Macular Retinal Vasculature Measurements in Healthy Eyes Determined by Two Different Scanning Protocols of Optical Coherence Tomography Angiography.
    Xiao H; Liu X; Liao L; Tan K; Ling Y; Zhong Y
    Ophthalmic Res; 2020; 63(3):244-251. PubMed ID: 31618736
    [TBL] [Abstract][Full Text] [Related]  

  • 17. OPTICAL COHERENCE TOMOGRAPHY ANGIOGRAPHY OF THE FOVEA IN CHILDREN BORN PRETERM.
    Falavarjani KG; Iafe NA; Velez FG; Schwartz SD; Sadda SR; Sarraf D; Tsui I
    Retina; 2017 Dec; 37(12):2289-2294. PubMed ID: 28098735
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Correlation of capillary plexus with visual acuity in idiopathic macular epiretinal membrane eyes using optical coherence tomography angiography].
    Mao JB; Lao JM; Yu XT; Chen YQ; Tao JW; Wu HF; Cheng D; Chen H; Shen LJ
    Zhonghua Yan Ke Za Zhi; 2019 Oct; 55(10):757-762. PubMed ID: 31607064
    [No Abstract]   [Full Text] [Related]  

  • 19. Evaluation of Automated Measurement of Macular Ischemic Changes in Retinal Vein Occlusion With Optical Coherence Tomography Angiography.
    Werner JU; Dreyhaupt J; Enders C
    Ophthalmic Surg Lasers Imaging Retina; 2023 Aug; 54(8):462-469. PubMed ID: 37535607
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative optical coherence tomography angiography of macular vascular structure and foveal avascular zone in glaucoma.
    Choi J; Kwon J; Shin JW; Lee J; Lee S; Kook MS
    PLoS One; 2017; 12(9):e0184948. PubMed ID: 28934255
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.