These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 32707697)

  • 21. The superiority of the two-thumb over the two-finger technique for single-rescuer infant cardiopulmonary resuscitation.
    Lee SY; Hong JY; Oh JH; Son SH
    Eur J Emerg Med; 2018 Oct; 25(5):372-376. PubMed ID: 28328729
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A Novel Infant Chest Compression Assist Device Using a Palm Rather Than Fingers: A Randomized Crossover Trial.
    Park JW; Jung JY; Kim J; Kwak YH; Kim DK; Lee JC; Ham EM; Hwang S; Kwon H
    Prehosp Emerg Care; 2019; 23(1):74-82. PubMed ID: 30118625
    [No Abstract]   [Full Text] [Related]  

  • 23. New chest compression method in infant resuscitation: Cross thumb technique.
    Jeon W; Kim J; Ko Y; Lee J
    PLoS One; 2022; 17(8):e0271636. PubMed ID: 35939436
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Effect of alternative chest compression techniques in infant and child on rescuer performance.
    Udassi JP; Udassi S; Theriaque DW; Shuster JJ; Zaritsky AL; Haque IU
    Pediatr Crit Care Med; 2009 May; 10(3):328-33. PubMed ID: 19307812
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effectiveness of finger-marker for maintaining the correct compression point during paediatric resuscitation: A simulation study.
    Jung JY; Kwak YH; Kwon H; Choi YJ; Kim DK; Kim HC; Lee JC; Park JH; Lim H
    Am J Emerg Med; 2017 Sep; 35(9):1303-1308. PubMed ID: 28483276
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Two-thumb-encircling advantageous for lay responder infant CPR: a randomised manikin study.
    Pellegrino JL; Bogumil D; Epstein JL; Burke RV
    Arch Dis Child; 2019 Jun; 104(6):530-534. PubMed ID: 30007942
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Differences in the performance of resuscitation according to the resuscitation guideline terminology during infant cardiopulmonary resuscitation: "Approximately 4 cm" versus "at least one-third the anterior-posterior diameter of the chest".
    Lee W; Yang D; Oh JH
    PLoS One; 2020; 15(3):e0230687. PubMed ID: 32208443
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Chest compression quality and rescuer fatigue with increased compression to ventilation ratio during single rescuer pediatric CPR.
    Haque IU; Udassi JP; Udassi S; Theriaque DW; Shuster JJ; Zaritsky AL
    Resuscitation; 2008 Oct; 79(1):82-9. PubMed ID: 18617314
    [TBL] [Abstract][Full Text] [Related]  

  • 29. The quality of a newly developed infant chest compression method applied by paramedics: a randomised crossover manikin trial.
    Smereka J; Kasiński M; Smereka A; Ładny JR; Szarpak Ł
    Kardiol Pol; 2017; 75(6):589-595. PubMed ID: 28150278
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Which Fingers Should We Perform Two-Finger Chest Compression Technique with When Performing Cardiopulmonary Resuscitation on an Infant in Cardiac Arrest?
    Kim YS; Oh JH; Kim CW; Kim SE; Lee DH; Hong JY
    J Korean Med Sci; 2016 Jun; 31(6):997-1002. PubMed ID: 27247512
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Incomplete chest wall decompression: a clinical evaluation of CPR performance by trained laypersons and an assessment of alternative manual chest compression-decompression techniques.
    Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Kitscha DJ; Provo TA; Lurie KG
    Resuscitation; 2006 Dec; 71(3):341-51. PubMed ID: 17070644
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Does a more "physiological" infant manikin design effect chest compression quality and create a potential for thoracic over-compression during simulated infant CPR?
    Martin PS; Kemp AM; Theobald PS; Maguire SA; Jones MD
    Resuscitation; 2013 May; 84(5):666-71. PubMed ID: 23123431
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Development of a diagnostic glove for unobtrusive measurement of chest compression force and depth during neonatal CPR.
    Dellimore K; Heunis S; Gohier F; Archer E; de Villiers A; Smith J; Scheffer C
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():350-3. PubMed ID: 24109696
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of a newly developed infant chest compression technique: A randomized crossover manikin trial.
    Smereka J; Bielski K; Ladny JR; Ruetzler K; Szarpak L
    Medicine (Baltimore); 2017 Apr; 96(14):e5915. PubMed ID: 28383397
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Which position should we take during newborn resuscitation? A prospective, randomised, multicentre simulation trial.
    Smereka J; Kaminska H; Wieczorek W; Dąbrowski M; Ładny JR; Ruetzler K; Szarpak Ł; Robak O; Frass M
    Kardiol Pol; 2018; 76(6):980-986. PubMed ID: 29350383
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Differences in Hands-off Time According to the Position of a Second Rescuer When Switching Compression in Pre-hospital Cardiopulmonary Resuscitation Provided by Two Bystanders: A Randomized, Controlled, Parallel Study.
    Kim YH; Lee JH; Lee DW; Cho KW; Kang MJ; Kim YW; Lee KY; Lee YH; Kim JJ; Hwang SY
    J Korean Med Sci; 2015 Sep; 30(9):1347-53. PubMed ID: 26339178
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A vertical two-thumb technique is superior to the two-thumb encircling technique for infant cardiopulmonary resuscitation.
    Na JU; Choi PC; Lee HJ; Shin DH; Han SK; Cho JH
    Acta Paediatr; 2015 Feb; 104(2):e70-5. PubMed ID: 25382371
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A comparison of the area of chest compression by the superimposed-thumb and the alongside-thumb techniques for infant cardiopulmonary resuscitation.
    Lee SH; Cho YC; Ryu S; Lee JW; Kim SW; Yoo IS; You YH; Lee BK; Park JS; Park SS; Jung WJ
    Resuscitation; 2011 Sep; 82(9):1214-7. PubMed ID: 21620550
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Two-Thumb Encircling Technique With a Novel Compression Assist Device Provides Safe and Effective Chest Compressions in Infants.
    Lee SU; Kim DK; Chang I; Jung JY; Paek SH; Park JW; Lee JH; Kwak YH
    Pediatr Emerg Care; 2020 Dec; 36(12):e700-e703. PubMed ID: 33170576
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of the 2010 American Heart Association Guidelines for infant CPR finger/thumb positions for chest compression: a study using computed tomography.
    Lee KH; Kim EY; Park DH; Kim JE; Choi HY; Cho J; Yang HJ
    Resuscitation; 2013 Jun; 84(6):766-9. PubMed ID: 23165233
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.