These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 327091)

  • 1. Percutaneous biopsy of renal transplants using ultrasonographic guidance.
    Spigos D; Capek V; Jonasson O
    J Urol; 1977 Jun; 117(6):699-700. PubMed ID: 327091
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of three methods to obtain percutaneous needle core biopsies of a renal allograft.
    Beckingham IJ; Nicholson ML; Kirk G; Veitch PS; Bell PR
    Br J Surg; 1994 Jun; 81(6):898-9. PubMed ID: 8044616
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Re: Percutaneous needle biopsy of the renal allograft using the automated needle system: evaluation of 87 procedures.
    Gómez Veiga F; Chantada Abal V; Gonzalez Martín M
    J Urol; 1994 Sep; 152(3):968. PubMed ID: 8080587
    [No Abstract]   [Full Text] [Related]  

  • 4. Percutaneous aspiration biopsy of renal allografts using ultrasound localization.
    Parker RA; Elliott WC; Muther RS; Golper TA; Barry JM; Henderson SC; Bennett WM
    Urology; 1980 May; 15(5):534-5. PubMed ID: 6763398
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Kidney biopsy from the viewpoint of a clinician].
    Thiel G; Brunner FP
    Bull Schweiz Akad Med Wiss; 1977 May; 33(1-3):141-58. PubMed ID: 328101
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Renal transplant biopsy using real time ultrasound guidance.
    Nicholson ML; Attard AR; Bell A; Donnelly PK; Veitch PS; Bell PR
    Br J Urol; 1990 Jun; 65(6):564-5. PubMed ID: 2196969
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Safety and efficacy of kidney transplant biopsy: Tru-Cut needle vs sonographically guided Biopty gun.
    Mahoney MC; Racadio JM; Merhar GL; First MR
    AJR Am J Roentgenol; 1993 Feb; 160(2):325-6. PubMed ID: 8424343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Renal transplants monitored with percutaneous biopsy and fine-needle aspiration cytology.
    Lloveras J; Cuxart M; Munné A; Orfila A; Mato E; Masramon J; Serrano S
    Transplant Proc; 1988 Oct; 20(5 Suppl 6):101-2. PubMed ID: 3051577
    [No Abstract]   [Full Text] [Related]  

  • 9. Automated renal transplant biopsy with real-time ultrasonic guidance.
    Cahen R; Trolliet P; Jean G; Megri K; Dijoud F; François B
    Transplant Proc; 1995 Apr; 27(2):1729-30. PubMed ID: 7725473
    [No Abstract]   [Full Text] [Related]  

  • 10. Percutaneous renal biopsy utilizing real time, ultrasonic guidance and a semiautomated biopsy device.
    Wiseman DA; Hawkins R; Numerow LM; Taub KJ
    Kidney Int; 1990 Aug; 38(2):347-9. PubMed ID: 2205753
    [No Abstract]   [Full Text] [Related]  

  • 11. No change in complication rate using spring-loaded gun compared to traditional percutaneous renal allograft biopsy techniques.
    Kovalik EC; Schwab SJ; Gunnells JC; Bowie D; Smith SR
    Clin Nephrol; 1996 Jun; 45(6):383-5. PubMed ID: 8793230
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous core-needle biopsy of renal transplant performed safely without radiographic aid: a prospective study.
    Wennberg L; Miyahara S; Wilczek HE
    Transplant Proc; 1994 Jun; 26(3):1769-70. PubMed ID: 8030126
    [No Abstract]   [Full Text] [Related]  

  • 13. Automated core biopsy of renal allografts using ultrasonic guidance.
    Erturk E; Rubens DJ; Panner BJ; Cerilli JG
    Transplantation; 1991 Jun; 51(6):1311-2. PubMed ID: 2048209
    [No Abstract]   [Full Text] [Related]  

  • 14. Ultrasound localization for percutaneous renal biopsy in children.
    Zeis PM; Spigos D; Samayoa C; Capek V; Aschinberg LC
    J Pediatr; 1976 Aug; 89(2):263-5. PubMed ID: 781205
    [No Abstract]   [Full Text] [Related]  

  • 15. Percutaneous renal transplant biopsy under CAT scanner guidance.
    Rao KV
    Nephron; 1984; 38(4):273-5. PubMed ID: 6392914
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [B-mode ultrasonic guidance for renal biopsy (author's transl)].
    Hasegawa H; Kazuta Y; Imada A; Horiuchi A
    Nihon Jinzo Gakkai Shi; 1980 Sep; 22(9):1141-6. PubMed ID: 7463849
    [No Abstract]   [Full Text] [Related]  

  • 17. [Percutaneous renal biopsy in the transplanted kidney].
    Torres Ramírez C; Zuluaga Gómez A; del Río Samper S; Puebla Ceverino M; Collado F; Girona Miralles A
    Arch Esp Urol; 1983; 36(1):28-31. PubMed ID: 6347100
    [No Abstract]   [Full Text] [Related]  

  • 18. Percutaneous renal biopsy in children under guidance of ultrasonic real time technique.
    Bachmann H; Heckemann R; Olbing H
    Int J Pediatr Nephrol; 1984 Sep; 5(3):175-8. PubMed ID: 6389389
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Immunoperoxidase staining of fine-needle aspiration biopsies and needle core biopsies from renal allografts.
    Bolton EM; Thompson JF; Wood RF; Morris PJ
    Transplantation; 1983 Dec; 36(6):728-31. PubMed ID: 6197793
    [No Abstract]   [Full Text] [Related]  

  • 20. Minicore needle biopsy of kidney transplants: a safer sampling method.
    Belitsky P; Gupta R
    J Urol; 1990 Aug; 144(2 Pt 1):310-1. PubMed ID: 2374195
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.