These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 32726957)

  • 1. Flexibility of Biodegradable Polymer Stents with Different Strut Geometries.
    Chen C; Xiong Y; Li Z; Chen Y
    Materials (Basel); 2020 Jul; 13(15):. PubMed ID: 32726957
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental and Numerical Simulation of Biodegradable Stents with Different Strut Geometries.
    Chen C; Xiong Y; Jiang W; Wang Y; Wang Z; Chen Y
    Cardiovasc Eng Technol; 2020 Feb; 11(1):36-46. PubMed ID: 31664685
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of stent structure on stent flexibility measurements.
    Mori K; Saito T
    Ann Biomed Eng; 2005 Jun; 33(6):733-42. PubMed ID: 16078613
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Study on the bending behavior of biodegradable metal cerebral vascular stents using finite element analysis.
    Shi W; Li H; Zhu T; Jin Y; Wang H; Yang J; Zhao D
    J Biomech; 2020 Jul; 108():109856. PubMed ID: 32635992
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Strut coverage and vessel wall response to a new-generation paclitaxel-eluting stent with an ultrathin biodegradable abluminal polymer: Optical Coherence Tomography Drug-Eluting Stent Investigation (OCTDESI).
    Guagliumi G; Sirbu V; Musumeci G; Bezerra HG; Aprile A; Kyono H; Fiocca L; Matiashvili A; Lortkipanidze N; Vassileva A; Popma JJ; Allocco DJ; Dawkins KD; Valsecchi O; Costa MA
    Circ Cardiovasc Interv; 2010 Aug; 3(4):367-75. PubMed ID: 20647562
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Geometry parameterization and multidisciplinary constrained optimization of coronary stents.
    Pant S; Bressloff NW; Limbert G
    Biomech Model Mechanobiol; 2012 Jan; 11(1-2):61-82. PubMed ID: 21373889
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multiobjective design optimization of stent geometry with wall deformation for triangular and rectangular struts.
    Putra NK; Palar PS; Anzai H; Shimoyama K; Ohta M
    Med Biol Eng Comput; 2019 Jan; 57(1):15-26. PubMed ID: 29967933
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of endovascular stent strut geometry on vascular injury, myointimal hyperplasia, and restenosis.
    Sullivan TM; Ainsworth SD; Langan EM; Taylor S; Snyder B; Cull D; Youkey J; Laberge M
    J Vasc Surg; 2002 Jul; 36(1):143-9. PubMed ID: 12096272
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optical coherence tomography findings: insights from the "randomised multicentre trial investigating angiographic outcomes of hybrid sirolimus-eluting stents with biodegradable polymer compared with everolimus-eluting stents with durable polymer in chronic total occlusions" (PRISON IV) trial.
    Teeuwen K; Spoormans EM; Bennett J; Dubois C; Desmet W; Ughi GJ; Belmans A; Kelder JC; Tijssen JGP; Agostoni P; Suttorp MJ; Adriaenssens T
    EuroIntervention; 2017 Aug; 13(5):e522-e530. PubMed ID: 28512069
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The relationship between post-stent strut apposition and follow-up strut coverage assessed by a contour plot optical coherence tomography analysis.
    Kim JS; Ha J; Kim BK; Shin DH; Ko YG; Choi D; Jang Y; Hong MK
    JACC Cardiovasc Interv; 2014 Jun; 7(6):641-51. PubMed ID: 24835329
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method.
    Liu Y; Zhu G; Yang H; Wang C; Zhang P; Han G
    J Mech Behav Biomed Mater; 2018 Jan; 77():157-163. PubMed ID: 28917130
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optical coherence tomography analysis of the stent strut and prediction of resolved strut malapposition at 3 months after 2nd-generation drug-eluting stent implantation.
    Izumi D; Miyahara M; Fujimoto N; Fukuoka S; Sakai M; Dohi K; Ito M
    Heart Vessels; 2016 Aug; 31(8):1247-56. PubMed ID: 26334709
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Strut apposition after coronary stent implantation visualised with optical coherence tomography.
    Radu M; Jørgensen E; Kelbaek H; Helqvist S; Skovgaard L; Saunamäki K
    EuroIntervention; 2010 May; 6(1):86-93. PubMed ID: 20542802
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optical coherence tomography at follow-up after percutaneous coronary intervention: relationship between procedural dissections, stent strut malapposition and stent healing.
    Radu M; Jørgensen E; Kelbæk H; Helqvist S; Skovgaard L; Saunamäki K
    EuroIntervention; 2011 Jul; 7(3):353-61. PubMed ID: 21729838
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Very thin strut biodegradable polymer everolimus-eluting and sirolimus-eluting stents versus durable polymer zotarolimus-eluting stents in allcomers with coronary artery disease (BIO-RESORT): a three-arm, randomised, non-inferiority trial.
    von Birgelen C; Kok MM; van der Heijden LC; Danse PW; Schotborgh CE; Scholte M; Gin RMTJ; Somi S; van Houwelingen KG; Stoel MG; de Man FHAF; Louwerenburg JHW; Hartmann M; Zocca P; Linssen GCM; van der Palen J; Doggen CJM; Löwik MM
    Lancet; 2016 Nov; 388(10060):2607-2617. PubMed ID: 27806902
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison between fractured Xience-like and Palmaz-like stents using a novel computational model.
    Tambaca J; Canić S; Paniagua D
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():1106-8. PubMed ID: 19964749
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcomes in Patients Treated With Thin-Strut, Very Thin-Strut, or Ultrathin-Strut Drug-Eluting Stents in Small Coronary Vessels: A Prespecified Analysis of the Randomized BIO-RESORT Trial.
    Buiten RA; Ploumen EH; Zocca P; Doggen CJM; van der Heijden LC; Kok MM; Danse PW; Schotborgh CE; Scholte M; de Man FHAF; Linssen GCM; von Birgelen C
    JAMA Cardiol; 2019 Jul; 4(7):659-669. PubMed ID: 31111862
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Early coverage of drug-eluting stents analysed by optical coherence tomography: evidence of the impact of stent apposition and strut characteristics on the neointimal healing process.
    Lee R; Foin N; Ng J; Allen J; Soh N; Ang I; Shim W; Torii R; Wong P
    EuroIntervention; 2016 Aug; 12(5):e605-14. PubMed ID: 27497360
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Flexibility and trackability of laser cut coronary stent systems.
    Szabadíts P; Puskás Z; Dobránszky J
    Acta Bioeng Biomech; 2009; 11(3):11-8. PubMed ID: 20131745
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Numerical investigation of the intravascular coronary stent flexibility.
    Petrini L; Migliavacca F; Auricchio F; Dubini G
    J Biomech; 2004 Apr; 37(4):495-501. PubMed ID: 14996561
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.