BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

213 related articles for article (PubMed ID: 32732597)

  • 1. Functional lung volume mapping with perfusion Single-Photon Emission Computed Tomography scan for radiotherapy planning in patients with locally advanced nonsmall cell lung cancer.
    Follacchio GA; D'Urso P; Cassese R; Ferrara C; Bulzonetti N; Monteleone F; Musio D; Liberatore M; Tombolini V
    Nucl Med Commun; 2020 Oct; 41(10):1026-1033. PubMed ID: 32732597
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A potential to reduce pulmonary toxicity: the use of perfusion SPECT with IMRT for functional lung avoidance in radiotherapy of non-small cell lung cancer.
    Lavrenkov K; Christian JA; Partridge M; Niotsikou E; Cook G; Parker M; Bedford JL; Brada M
    Radiother Oncol; 2007 May; 83(2):156-62. PubMed ID: 17493699
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ga-68 MAA Perfusion 4D-PET/CT Scanning Allows for Functional Lung Avoidance Using Conformal Radiation Therapy Planning.
    Siva S; Devereux T; Ball DL; MacManus MP; Hardcastle N; Kron T; Bressel M; Foroudi F; Plumridge N; Steinfort D; Shaw M; Callahan J; Hicks RJ; Hofman MS
    Technol Cancer Res Treat; 2016 Feb; 15(1):114-21. PubMed ID: 25575575
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Potential for reduced toxicity and dose escalation in the treatment of inoperable non-small-cell lung cancer: a comparison of intensity-modulated radiation therapy (IMRT), 3D conformal radiation, and elective nodal irradiation.
    Grills IS; Yan D; Martinez AA; Vicini FA; Wong JW; Kestin LL
    Int J Radiat Oncol Biol Phys; 2003 Nov; 57(3):875-90. PubMed ID: 14529795
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Preserving functional lung using perfusion imaging and intensity-modulated radiation therapy for advanced-stage non-small cell lung cancer.
    Shioyama Y; Jang SY; Liu HH; Guerrero T; Wang X; Gayed IW; Erwin WD; Liao Z; Chang JY; Jeter M; Yaremko BP; Borghero YO; Cox JD; Komaki R; Mohan R
    Int J Radiat Oncol Biol Phys; 2007 Aug; 68(5):1349-58. PubMed ID: 17446001
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intensity modulated radiotherapy of non-small-cell lung cancer incorporating SPECT ventilation imaging.
    Munawar I; Yaremko BP; Craig J; Oliver M; Gaede S; Rodrigues G; Yu E; Reid RH; Leung E; Urbain JL; Chen J; Wong E
    Med Phys; 2010 Apr; 37(4):1863-72. PubMed ID: 20443508
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Image-based lung functional radiotherapy planning for non-small cell lung cancer.
    Mounessi FS; Eckardt J; Holstein A; Ewig S; Könemann S
    Strahlenther Onkol; 2020 Feb; 196(2):151-158. PubMed ID: 31578598
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single photon emission computed tomography (SPECT) or positron emission tomography (PET) imaging for radiotherapy planning in patients with lung cancer: a meta-analysis.
    Lee SJ; Park HJ
    Sci Rep; 2020 Sep; 10(1):14864. PubMed ID: 32913277
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effective avoidance of a functional spect-perfused lung using intensity modulated radiotherapy (IMRT) for non-small cell lung cancer (NSCLC): an update of a planning study.
    Lavrenkov K; Singh S; Christian JA; Partridge M; Nioutsikou E; Cook G; Bedford JL; Brada M
    Radiother Oncol; 2009 Jun; 91(3):349-52. PubMed ID: 18995919
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Protection of lung function by introducing single photon emission computed tomography lung perfusion image into radiotherapy plan of lung cancer.
    Yin Y; Chen JH; Li BS; Liu TH; Lu J; Bai T; Dong XL; Yu JM
    Chin Med J (Engl); 2009 Mar; 122(5):509-13. PubMed ID: 19323899
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intensity-modulated radiotherapy for locally advanced non-small-cell lung cancer: a dose-escalation planning study.
    Lievens Y; Nulens A; Gaber MA; Defraene G; De Wever W; Stroobants S; Van den Heuvel F;
    Int J Radiat Oncol Biol Phys; 2011 May; 80(1):306-13. PubMed ID: 20888706
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Initial report on feasibility of PET/CT-based image-guided moderate hypofractionated thoracic irradiation in node-positive non-small cell lung Cancer patients with poor prognostic factors and strongly diminished lung function: a retrospective analysis.
    Eze C; Taugner J; Roengvoraphoj O; Schmidt-Hegemann NS; Käsmann L; Wijaya C; Belka C; Manapov F
    Radiat Oncol; 2019 Sep; 14(1):163. PubMed ID: 31484542
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inclusion of functional information from perfusion SPECT improves predictive value of dose-volume parameters in lung toxicity outcome after radiotherapy for non-small cell lung cancer: A prospective study.
    Farr KP; Kallehauge JF; Møller DS; Khalil AA; Kramer S; Bluhme H; Morsing A; Grau C
    Radiother Oncol; 2015 Oct; 117(1):9-16. PubMed ID: 26303012
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation of Functional Lung Heterogeneity and Dosimetry to Radiation Pneumonitis using Perfusion SPECT/CT and FDG PET/CT Imaging.
    Lee HJ; Zeng J; Vesselle HJ; Patel SA; Rengan R; Bowen SR
    Int J Radiat Oncol Biol Phys; 2018 Nov; 102(4):1255-1264. PubMed ID: 30108002
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incorporating quantitative single photon emission computed tomography into radiation therapy treatment planning for lung cancer: impact of attenuation and scatter correction on the single photon emission computed tomography-weighted mean dose and functional lung segmentation.
    Yin L; Shcherbinin S; Celler A; Thompson A; Fua TF; Liu M; Duzenli C; Gill B; Sheehan F; Powe J; Worsley D; Marks L; Moiseenko V
    Int J Radiat Oncol Biol Phys; 2010 Oct; 78(2):587-94. PubMed ID: 20452138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Integration of computerized tomography imaging with single photon emission in a commercial system for developing radiotherapy fields: application to conformational irradiation for lung carcinoma].
    Cattaneo GM; Rizzo G; Lombardi P; Ceresoli G; Savi A; Gilardi MC; Villa E; Calandrino R
    Radiol Med; 1999 Apr; 97(4):272-8. PubMed ID: 10414261
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reduction of normal lung irradiation in locally advanced non-small-cell lung cancer patients, using ventilation images for functional avoidance.
    Yaremko BP; Guerrero TM; Noyola-Martinez J; Guerra R; Lege DG; Nguyen LT; Balter PA; Cox JD; Komaki R
    Int J Radiat Oncol Biol Phys; 2007 Jun; 68(2):562-71. PubMed ID: 17398028
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Functional image-based radiotherapy planning for non-small cell lung cancer: A simulation study.
    Bates EL; Bragg CM; Wild JM; Hatton MQ; Ireland RH
    Radiother Oncol; 2009 Oct; 93(1):32-6. PubMed ID: 19552978
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Spect-guidance to reduce radioactive dose to functioning lung for stage III non-small cell lung cancer.
    Wang ZT; Wei LL; Ding XP; Sun MP; Sun HF; Li BS
    Asian Pac J Cancer Prev; 2013; 14(2):1061-5. PubMed ID: 23621187
    [TBL] [Abstract][Full Text] [Related]  

  • 20. IMRT and 3D conformal radiotherapy with or without elective nodal irradiation in locally advanced NSCLC: A direct comparison of PET-based treatment planning.
    Fleckenstein J; Kremp K; Kremp S; Palm J; Rübe C
    Strahlenther Onkol; 2016 Feb; 192(2):75-82. PubMed ID: 26438071
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.