These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 32740350)

  • 1. Biologically Inspired, Open, Helicoid Impeller Design for Mechanical Circulatory Assist.
    Park J; Oki K; Hesselmann F; Geirsson A; Kaufmann T; Bonde P
    ASAIO J; 2020 Aug; 66(8):899-908. PubMed ID: 32740350
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impeller (straight blade) design variations and their influence on the performance of a centrifugal blood pump.
    Fang P; Du J; Yu S
    Int J Artif Organs; 2020 Dec; 43(12):782-795. PubMed ID: 32312159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Influence of rotor impeller structure on performance improvement of suspended axial flow blood pumps.
    Wang L; Yun Z; Tang X; Xiang C
    Int J Artif Organs; 2024 Mar; 47(3):162-172. PubMed ID: 38450429
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Computational Fluid Dynamics Model of Continuous-Flow Total Artificial Heart: Right Pump Impeller Design Changes to Improve Biocompatibility.
    Goodin MS; Horvath DJ; Kuban BD; Polakowski AR; Fukamachi K; Flick CR; Karimov JH
    ASAIO J; 2022 Jun; 68(6):829-838. PubMed ID: 34560715
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the impeller shroud performance of an axial flow ventricular assist device using computational fluid dynamics.
    Su B; Chua LP; Lim TM; Zhou T
    Artif Organs; 2010 Sep; 34(9):745-59. PubMed ID: 20883393
    [TBL] [Abstract][Full Text] [Related]  

  • 6. New investigations of a pulsatile impeller blood pump.
    Qian KX
    ASAIO Trans; 1990; 36(1):33-5. PubMed ID: 2306388
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of impeller rotational phase on the FDA blood pump velocity fields.
    Ucak K; Karatas F; Pekkan K
    Artif Organs; 2024 Oct; 48(10):1126-1137. PubMed ID: 38957988
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of blade curvature on the hemolytic and hydraulic characteristics of a centrifugal blood pump.
    Ozturk C; Aka IB; Lazoglu I
    Int J Artif Organs; 2018 Nov; 41(11):730-737. PubMed ID: 29998774
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device.
    Wu J; Paden BE; Borovetz HS; Antaki JF
    Artif Organs; 2010 May; 34(5):402-11. PubMed ID: 19832736
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of an axial flow ventricular assist device: in vitro and in vivo evaluation.
    Mizuguchi K; Damm G; Benkowsky R; Aber G; Bacak J; Svjkovsky P; Glueck J; Takatani S; Nosé Y; Noon GP
    Artif Organs; 1995 Jul; 19(7):653-9. PubMed ID: 8572968
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Numerical study of a bio-centrifugal blood pump with straight impeller blade profiles.
    Song G; Chua LP; Lim TM
    Artif Organs; 2010 Feb; 34(2):98-104. PubMed ID: 19817732
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of the Center Post Establishment and Its Design Variations on the Performance of a Centrifugal Rotary Blood Pump.
    Fang P; Du J; Yu S
    Cardiovasc Eng Technol; 2020 Aug; 11(4):337-349. PubMed ID: 32410073
    [TBL] [Abstract][Full Text] [Related]  

  • 13. CFD-Based Flow Channel Optimization and Performance Prediction for a Conical Axial Maglev Blood Pump.
    Yang W; Peng S; Xiao W; Hu Y; Wu H; Li M
    Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214544
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimization design of semi-open impeller based on thrombogenicity in a blood pump.
    Liu X; Shao J; Wang P; Zhao H; Liu L; Han Q
    Artif Organs; 2024 Sep; 48(9):1060-1069. PubMed ID: 38922991
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Channel impeller design for centrifugal blood pump in hybrid pediatric total artificial heart: Modeling, magnet integration, and hydraulic experiments.
    Hirschhorn M; Catucci N; Day SW; Stevens RM; Tchantchaleishvili V; Throckmorton AL
    Artif Organs; 2023 Apr; 47(4):680-694. PubMed ID: 36524792
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The impact of rotor configurations on hemodynamic features, hemocompatibility and dynamic balance of the centrifugal blood pump: A numerical study.
    Li Y; Xi Y; Wang H; Sun A; Deng X; Chen Z; Fan Y
    Int J Numer Method Biomed Eng; 2023 Feb; 39(2):e3671. PubMed ID: 36507614
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Structural improvement study of streamline design method, conical hub, and auxiliary blades for axial blood pump.
    Yu Z; Tan J; Wang S; Guo B
    Int J Artif Organs; 2021 Apr; 44(4):251-261. PubMed ID: 32957840
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Proposal of hemodynamically improved design of an axial flow blood pump for LVAD.
    Kannojiya V; Das AK; Das PK
    Med Biol Eng Comput; 2020 Feb; 58(2):401-418. PubMed ID: 31858420
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Design of an axial blood pump of diffuser with splitter blades and cantilevered main blades].
    Liu G; Xi J; Chen H; Zhang Y; Hou J; Zhou J; Sun H; Hu S
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2019 Jun; 36(3):379-385. PubMed ID: 31232539
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Computational flow study of the continuous flow ventricular assist device, prototype number 3 blood pump.
    Anderson JB; Wood HG; Allaire PE; Bearnson G; Khanwilkar P
    Artif Organs; 2000 May; 24(5):377-85. PubMed ID: 10848679
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.