BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

175 related articles for article (PubMed ID: 32741036)

  • 1. Endovascular treatment of an anastomotic outflow graft pseudoaneurysm of the descending aorta after implantation of a left ventricular assist device.
    Nersesian G; Solowjowa N; Falk V; Potapov E; Buz S
    J Card Surg; 2020 Nov; 35(11):3195-3198. PubMed ID: 32741036
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Left Ventricular Assist Device Outflow Graft Pseudoaneurysm Treated with Covered Balloon Expandable Stent.
    Pya Y; Mussayev A; Alimbayev S; Medressova A; Bekbossynov S; Andossova S; Khissamutdinov N; Jetybayeva S; la Fleur P
    ASAIO J; 2020 May; 66(5):e74-e76. PubMed ID: 31192842
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Endovascular repair of left ventricular assist device outflow graft defect.
    Teman NR; Shah SM; Downs E; Ailawadi G; Mazimba S; Fritz Angle J; Khaja MS; Yarboro LT
    J Card Surg; 2020 Nov; 35(11):3235-3238. PubMed ID: 32970354
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contained rupture of a pseudoaneurysm of the descending thoracic aorta related to remnant outflow graft of left ventricular assist device after heart transplantation.
    Yamane K; Bogar LJ; DiMuzio PJ; Cowan SW; Hirose H; Evans NR; Rao AS; Eisenberg JA; Cavarocchi NC
    Ann Thorac Surg; 2012 Oct; 94(4):1345-8. PubMed ID: 23006696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Endovascular stent grafting of a left ventricular assist device outflow graft pseudoaneurysm.
    Ganapathi AM; Andersen ND; Prastein DJ; Hashmi ZA; Rogers JG; Milano CA; McCann RL; Hughes GC
    Circ Heart Fail; 2013 Jan; 6(1):e16-8. PubMed ID: 23322880
    [No Abstract]   [Full Text] [Related]  

  • 6. Surgical treatment of outflow graft kinking complicated by external obstruction with a fibrin mass in a patient with LVAD.
    Nersesian G; Van Praet KM; van Kampen A; Solowjowa N; Falk V; Potapov E
    J Card Surg; 2020 Oct; 35(10):2853-2856. PubMed ID: 32683721
    [TBL] [Abstract][Full Text] [Related]  

  • 7. From bench to bedside: Impact of left ventricular assist device outflow conduit anastomosis position on outcome.
    Tarzia V; Di Giammarco G; Bagozzi L; Bortolussi G; Maccherini M; Marinelli D; Bernazzali S; Maiani M; Gregori D; Scuri S; Tessari C; Fabozzo A; Bottio T; Livi U; Gerosa G
    Artif Organs; 2021 Mar; 45(3):236-243. PubMed ID: 32860268
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stent graft repair of paraanastomotic aneurysms after open descending thoracic and thoracoabdominal aortic aneurysm repair.
    O'Connor DJ; Vouyouka A; Ellozy SH; Sundick SA; Lemasters P; Marin ML; Faries PL
    Ann Vasc Surg; 2013 Aug; 27(6):693-8. PubMed ID: 23540669
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Endovascular aortic stent graft placement to exclude the left ventricular assist device outflow graft on the descending aorta during heart transplant.
    Jouan J; Alsac JM; Bel A; Grinda JM
    J Thorac Cardiovasc Surg; 2019 Jun; 157(6):e387-e389. PubMed ID: 30642621
    [No Abstract]   [Full Text] [Related]  

  • 10. Late outflow graft stenosis of left ventricular assist device and endovascular treatment.
    Karaca S; Erdinli D; Kahraman U; Çınar C; Engin Ç; Yağdı T; Özbaran M
    J Artif Organs; 2024 Jun; 27(2):154-158. PubMed ID: 37145261
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reinforcement of left ventricular assist device outflow grafts to prevent kinking.
    Cohn WE; Gregoric ID; Frazier OH
    Ann Thorac Surg; 2007 Jul; 84(1):301-2. PubMed ID: 17588447
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Exercise capacity following ventricular assist device implantation via thoracotomy with outflow cannula anastomosis to the descending aorta.
    Dorken Gallastegi A; Kahraman Ü; Yağmur B; Çınar E; Nalbantgil S; Engin Ç; Yağdı T; Özbaran M
    Artif Organs; 2021 Nov; 45(11):1317-1327. PubMed ID: 34153119
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Left ventricular assist device implantation with left lateral thoracotomy with anastomosis to the descending aorta.
    Ozbaran M; Yagdi T; Engin C; Nalbantgil S; Ozturk P
    Interact Cardiovasc Thorac Surg; 2018 Aug; 27(2):186-190. PubMed ID: 29554252
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Far From the Septum: Transcatheter Cardioform Septal Occluder Device Closure of a Descending Aortic Pseudoaneurysm Late After Interrupted Aortic Arch Repair.
    Pater C; Brown NM; Goldstein BH
    JACC Cardiovasc Interv; 2017 Sep; 10(17):e163-e166. PubMed ID: 28823776
    [No Abstract]   [Full Text] [Related]  

  • 15. Pump-assisted total arch replacement using an in situ stent graft fenestration technique.
    Eslami MH; Sherburne A; Gupta A; Lazar HL
    J Card Surg; 2014 Nov; 29(6):816-20. PubMed ID: 25040153
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Outcomes of midterm circulatory support by left ventricular assist device implantation with descending aortic anastomosis.
    Nawata K; Nishimura T; Kyo S; Hisagi M; Kinoshita O; Saito A; Motomura N; Takamoto S; Ono M
    J Artif Organs; 2010 Dec; 13(4):197-201. PubMed ID: 21049276
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Bridge to Transplantation With Long-Term Mechanical Assist Devices in Adults With Transposition of the Great Arteries.
    Michel E; Orozco Hernandez E; Enter D; Monge M; Nakano J; Rich J; Anderson A; Backer C; McCarthy P; Pham D
    Artif Organs; 2019 Jan; 43(1):90-96. PubMed ID: 30129258
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endovascular repair for thoracic aortic pseudoaneurysm induced by pedicle screw implantation: a case report with 8 years follow-up.
    Zhou S; Han H; Zhang Y; Shu C; Luo M
    J Cardiothorac Surg; 2024 Jun; 19(1):326. PubMed ID: 38849846
    [TBL] [Abstract][Full Text] [Related]  

  • 19. First results of HeartWare left ventricular assist device implantation with tunnelling of the outflow graft through the transverse sinus.
    Hanke JS; Rojas SV; Cvitkovic T; Wiegmann B; Horke A; Warnecke G; Haverich A; Schmitto JD
    Interact Cardiovasc Thorac Surg; 2017 Oct; 25(4):503-508. PubMed ID: 28962493
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Bailout Implantation of a New Single-Branch Stent Graft for the Aortic Arch.
    Cibin G; D'Onofrio A; Antonello M; Guglielmi C; Grego F; Gerosa G
    Ann Thorac Surg; 2020 Nov; 110(5):e371-e373. PubMed ID: 32376356
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.