  • 1. Comparison of Heart Proportions Compressed by Chest Compressions Between Geriatric and Nongeriatric Patients Using Mathematical Methods and Chest Computed Tomography: A Retrospective Study.
    Yoo KH; Oh J; Lee H; Lee J; Kang H; Lim TH; Song SY; Kim S
    Ann Geriatr Med Res; 2018 Sep; 22(3):130-136. PubMed ID: 32743262
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the Neonatal Resuscitation Program's recommended chest compression depth using computerized tomography imaging.
    Meyer A; Nadkarni V; Pollock A; Babbs C; Nishisaki A; Braga M; Berg RA; Ades A
    Resuscitation; 2010 May; 81(5):544-8. PubMed ID: 20223576
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Radiological assessment of the adult chest: implications for chest compressions.
    Pickard A; Darby M; Soar J
    Resuscitation; 2006 Dec; 71(3):387-90. PubMed ID: 16982125
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Appropriateness of recommended chest compression depths for cardiopulmonary resuscitation based on chest computed tomography parameters among Thai population: A multicenter retrospective study.
    Sanguanwit P; Saksobhavivat N; Phattharapornjaroen P; Atiksawedparit P; Chalermdamrichai P; Saelee R; Jantataeme P; Na Petvicharn K; Lawantuksin N; Paosaree P; Klongklaew P; Prakongsin A; Walanchaphruk D; Wattanaruengchai P; Surapornpaiboon S; Chartkul M
    Resusc Plus; 2024 Jun; 18():100605. PubMed ID: 38549692
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Does a more "physiological" infant manikin design effect chest compression quality and create a potential for thoracic over-compression during simulated infant CPR?
    Martin PS; Kemp AM; Theobald PS; Maguire SA; Jones MD
    Resuscitation; 2013 May; 84(5):666-71. PubMed ID: 23123431
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Estimation of optimal CPR chest compression depth in children by using computer tomography.
    Braga MS; Dominguez TE; Pollock AN; Niles D; Meyer A; Myklebust H; Nysaether J; Nadkarni V
    Pediatrics; 2009 Jul; 124(1):e69-74. PubMed ID: 19564271
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Depth of sternal compression and intra-arterial blood pressure during CPR in infants following cardiac surgery.
    Maher KO; Berg RA; Lindsey CW; Simsic J; Mahle WT
    Resuscitation; 2009 Jun; 80(6):662-4. PubMed ID: 19403232
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the proper chest compression depth for neonatal resuscitation using computed tomography: A retrospective study.
    Lee J; Lee DK; Oh J; Park SM; Kang H; Lim TH; Jo YH; Ko BS; Cho Y
    Medicine (Baltimore); 2021 Jul; 100(26):e26122. PubMed ID: 34190144
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Chest compression-associated injuries in cardiac arrest patients treated with manual chest compressions versus automated chest compression devices (LUCAS II) - a forensic autopsy-based comparison.
    Ondruschka B; Baier C; Bayer R; Hammer N; Dreßler J; Bernhard M
    Forensic Sci Med Pathol; 2018 Dec; 14(4):515-525. PubMed ID: 30203237
    [TBL] [Abstract][Full Text] [Related]  

  • 10. 2017 American Heart Association Focused Update on Pediatric Basic Life Support and Cardiopulmonary Resuscitation Quality: An Update to the American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.
    Atkins DL; de Caen AR; Berger S; Samson RA; Schexnayder SM; Joyner BL; Bigham BL; Niles DE; Duff JP; Hunt EA; Meaney PA
    Circulation; 2018 Jan; 137(1):e1-e6. PubMed ID: 29114009
    [TBL] [Abstract][Full Text] [Related]  

  • 11. What is the potential for over-compression using current paediatric chest compression guidelines? - A chest computed tomography study.
    Ong GY; Ang AJF; S O Aurangzeb A; Fong ESS; Tan JY; Chen ZJ; Chan YH; Tang PH; Pek JH; Maconochie I; Ng KC; Nadkarni V
    Resusc Plus; 2021 Jun; 6():100112. PubMed ID: 34223372
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Retrospective Study Using Computed Tomography to Compare Sufficient Chest Compression Depth for Cardiopulmonary Resuscitation in Obese Patients.
    Lee H; Oh J; Lee J; Kang H; Lim TH; Ko BS; Cho Y; Song SY
    J Am Heart Assoc; 2019 Dec; 8(23):e013948. PubMed ID: 31766971
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Verification of the Optimal Chest Compression Depth for Children in the 2015 American Heart Association Guidelines: Computed Tomography Study.
    Kim YH; Lee JH; Cho KW; Lee DW; Kang MJ; Lee KY; Byun JH; Lee YH; Hwang SY; Lee NK
    Pediatr Crit Care Med; 2018 Jan; 19(1):e1-e6. PubMed ID: 29135701
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Real-time feedback improves chest compression quality in out-of-hospital cardiac arrest: A prospective cohort study.
    Lakomek F; Lukas RP; Brinkrolf P; Mennewisch A; Steinsiek N; Gutendorf P; Sudowe H; Heller M; Kwiecien R; Zarbock A; Bohn A
    PLoS One; 2020; 15(2):e0229431. PubMed ID: 32092113
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous chest compression versus interrupted chest compression for cardiopulmonary resuscitation of non-asphyxial out-of-hospital cardiac arrest.
    Zhan L; Yang LJ; Huang Y; He Q; Liu GJ
    Cochrane Database Syst Rev; 2017 Mar; 3(3):CD010134. PubMed ID: 28349529
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Chest Compression Fraction Alone Does Not Adequately Measure Cardiopulmonary Resuscitation Quality in Out-of-Hospital Cardiac Arrest.
    Loza-Gomez A; Johnson M; Newby M; LeGassick T; Larmon B
    J Emerg Med; 2022 Mar; 62(3):e35-e43. PubMed ID: 35058094
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimal position for external chest compression during cardiopulmonary resuscitation: an analysis based on chest CT in patients resuscitated from cardiac arrest.
    Cha KC; Kim YJ; Shin HJ; Cha YS; Kim H; Lee KH; Kwon W; Hwang SO
    Emerg Med J; 2013 Aug; 30(8):615-9. PubMed ID: 22833601
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Current Guideline of Chest Compression Depth for Children of All Ages May Be Too Deep for Younger Children.
    Lee JH; Han SK; Na JU
    Emerg Med Int; 2019; 2019():7841759. PubMed ID: 31321100
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simulation intervention with manikin-based objective metrics improves CPR instructor chest compression performance skills without improvement in chest compression assessment skills.
    Al-Rasheed RS; Devine J; Dunbar-Viveiros JA; Jones MS; Dannecker M; Machan JT; Jay GD; Kobayashi L
    Simul Healthc; 2013 Aug; 8(4):242-52. PubMed ID: 23842118
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Impact of Backboard Placement on Chest Compression Quality: A Mannequin Study.
    Sanri E; Karacabey S
    Prehosp Disaster Med; 2019 Apr; 34(2):182-187. PubMed ID: 30981288
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]