212 related articles for article (PubMed ID: 32746051)
1. Knee Compliance Reduces Peak Swing Phase Collision Forces in a Lower-Limb Exoskeleton Leg: A Test Bench Evaluation.
Schrade SO; Menner M; Shirota C; Winiger P; Stutz A; Zeilinger MN; Lambercy O; Gassert R
IEEE Trans Biomed Eng; 2021 Feb; 68(2):535-544. PubMed ID: 32746051
[TBL] [Abstract][Full Text] [Related]
2. Bio-inspired control of joint torque and knee stiffness in a robotic lower limb exoskeleton using a central pattern generator.
Schrade SO; Nager Y; Wu AR; Gassert R; Ijspeert A
IEEE Int Conf Rehabil Robot; 2017 Jul; 2017():1387-1394. PubMed ID: 28814014
[TBL] [Abstract][Full Text] [Related]
3. Development of VariLeg, an exoskeleton with variable stiffness actuation: first results and user evaluation from the CYBATHLON 2016.
Schrade SO; Dätwyler K; Stücheli M; Studer K; Türk DA; Meboldt M; Gassert R; Lambercy O
J Neuroeng Rehabil; 2018 Mar; 15(1):18. PubMed ID: 29534730
[TBL] [Abstract][Full Text] [Related]
4. Novel swing-assist un-motorized exoskeletons for gait training.
Mankala KK; Banala SK; Agrawal SK
J Neuroeng Rehabil; 2009 Jul; 6():24. PubMed ID: 19575808
[TBL] [Abstract][Full Text] [Related]
5. A Model-Based Method for Minimizing Reflected Motor Inertia in Off-board Actuation Systems: Applications in Exoskeleton Design.
Anderson A; Richburg C; Czerniecki J; Aubin P
IEEE Int Conf Rehabil Robot; 2019 Jun; 2019():360-367. PubMed ID: 31374656
[TBL] [Abstract][Full Text] [Related]
6. Joint stiffness modulation of compliant actuators for lower limb exoskeletons.
Gonzalez-Vargas J; Shimoda S; Asin-Prieto G; Pons JL; Moreno JC
IEEE Int Conf Rehabil Robot; 2017 Jul; 2017():1287-1292. PubMed ID: 28813998
[TBL] [Abstract][Full Text] [Related]
7. Assessing effects of exoskeleton misalignment on knee joint load during swing using an instrumented leg simulator.
Bessler-Etten J; Schaake L; Prange-Lasonder GB; Buurke JH
J Neuroeng Rehabil; 2022 Jan; 19(1):13. PubMed ID: 35090501
[TBL] [Abstract][Full Text] [Related]
8. Preliminary Assessment of a Compliant Gait Exoskeleton.
Cestari M; Sanz-Merodio D; Garcia E
Soft Robot; 2017 Jun; 4(2):135-146. PubMed ID: 29182092
[TBL] [Abstract][Full Text] [Related]
9. Design of the Clutched Variable Parallel Elastic Actuator (CVPEA) for Lower Limb Exoskeletons.
Li Y; Li Z; Penzlin B; Tang Z; Liu Y; Guan X; Ji L; Leonhardt S
Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():4436-4439. PubMed ID: 31946850
[TBL] [Abstract][Full Text] [Related]
10. Exoskeletons' design and usefulness evidence according to a systematic review of lower limb exoskeletons used for functional mobility by people with spinal cord injury.
Lajeunesse V; Vincent C; Routhier F; Careau E; Michaud F
Disabil Rehabil Assist Technol; 2016 Oct; 11(7):535-47. PubMed ID: 26340538
[TBL] [Abstract][Full Text] [Related]
11. Self-Aligning Mechanism Improves Comfort and Performance With a Powered Knee Exoskeleton.
Sarkisian SV; Ishmael MK; Lenzi T
IEEE Trans Neural Syst Rehabil Eng; 2021; 29():629-640. PubMed ID: 33684041
[TBL] [Abstract][Full Text] [Related]
12. A Human Lower Limb Mechanical Phantom for the Testing of Knee Exoskeletons.
Barrutia WS; Bratt J; Ferris DP
IEEE Trans Neural Syst Rehabil Eng; 2023; 31():2497-2506. PubMed ID: 37186529
[TBL] [Abstract][Full Text] [Related]
13. Estimating upper extremity joint loads of persons with spinal cord injury walking with a lower extremity powered exoskeleton and forearm crutches.
Smith AJJ; Fournier BN; Nantel J; Lemaire ED
J Biomech; 2020 Jun; 107():109835. PubMed ID: 32517865
[TBL] [Abstract][Full Text] [Related]
14. Model-based control for exoskeletons with series elastic actuators evaluated on sit-to-stand movements.
Vantilt J; Tanghe K; Afschrift M; Bruijnes AKBD; Junius K; Geeroms J; Aertbeliën E; De Groote F; Lefeber D; Jonkers I; De Schutter J
J Neuroeng Rehabil; 2019 Jun; 16(1):65. PubMed ID: 31159874
[TBL] [Abstract][Full Text] [Related]
15. A Kinematic Model of a Humanoid Lower Limb Exoskeleton with Hydraulic Actuators.
Glowinski S; Krzyzynski T; Bryndal A; Maciejewski I
Sensors (Basel); 2020 Oct; 20(21):. PubMed ID: 33121194
[TBL] [Abstract][Full Text] [Related]
16. Design of a Payload Adjustment Device for an Unpowered Lower-Limb Exoskeleton.
Yun J; Kang O; Joe HM
Sensors (Basel); 2021 Jun; 21(12):. PubMed ID: 34208291
[TBL] [Abstract][Full Text] [Related]
17. Running With an Elastic Lower Limb Exoskeleton.
Cherry MS; Kota S; Young A; Ferris DP
J Appl Biomech; 2016 Jun; 32(3):269-77. PubMed ID: 26694976
[TBL] [Abstract][Full Text] [Related]
18. Development of a Single Leg Knee Exoskeleton and Sensing Knee Center of Rotation Change for Intention Detection.
Moon DH; Kim D; Hong YD
Sensors (Basel); 2019 Sep; 19(18):. PubMed ID: 31540298
[TBL] [Abstract][Full Text] [Related]
19. Design of a lightweight, tethered, torque-controlled knee exoskeleton.
Witte KA; Fatschel AM; Collins SH
IEEE Int Conf Rehabil Robot; 2017 Jul; 2017():1646-1653. PubMed ID: 28814056
[TBL] [Abstract][Full Text] [Related]
20. Modulating Multiarticular Energy during Human Walking and Running with an Unpowered Exoskeleton.
Zhou T; Zhou Z; Zhang H; Chen W
Sensors (Basel); 2022 Nov; 22(21):. PubMed ID: 36366237
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]