143 related articles for article (PubMed ID: 32746346)
1. Injectable Sensors Based on Passive Rectification of Volume-Conducted Currents.
Malik S; Castellvi Q; Becerra-Fajardo L; Tudela-Pi M; Garcia-Moreno A; Baghini MS; Ivorra A
IEEE Trans Biomed Circuits Syst; 2020 Aug; 14(4):867-878. PubMed ID: 32746346
[TBL] [Abstract][Full Text] [Related]
2. Powering Electronic Implants by High Frequency Volume Conduction: In Human Validation.
Minguillon J; Tudela-Pi M; Becerra-Fajardo L; Perera-Bel E; Del-Ama AJ; Gil-Agudo A; Megia-Garcia A; Garcia-Moreno A; Ivorra A
IEEE Trans Biomed Eng; 2023 Feb; 70(2):659-670. PubMed ID: 35994554
[TBL] [Abstract][Full Text] [Related]
3. In vivo demonstration of injectable microstimulators based on charge-balanced rectification of epidermically applied currents.
Ivorra A; Becerra-Fajardo L; Castellví Q
J Neural Eng; 2015 Dec; 12(6):066010. PubMed ID: 26447945
[TBL] [Abstract][Full Text] [Related]
4. Wireless networks of injectable microelectronic stimulators based on rectification of volume conducted high frequency currents.
García-Moreno A; Comerma-Montells A; Tudela-Pi M; Minguillon J; Becerra-Fajardo L; Ivorra A
J Neural Eng; 2022 Sep; 19(5):. PubMed ID: 36041421
[No Abstract] [Full Text] [Related]
5. Floating EMG sensors and stimulators wirelessly powered and operated by volume conduction for networked neuroprosthetics.
Becerra-Fajardo L; Krob MO; Minguillon J; Rodrigues C; Welsch C; Tudela-Pi M; Comerma A; Oliveira Barroso F; Schneider A; Ivorra A
J Neuroeng Rehabil; 2022 Jun; 19(1):57. PubMed ID: 35672857
[TBL] [Abstract][Full Text] [Related]
6. A package design technique for size reduction of implantable bioelectronic systems.
Soma M
IEEE Trans Biomed Eng; 1990 May; 37(5):482-8. PubMed ID: 2345004
[TBL] [Abstract][Full Text] [Related]
7. In Vivo Demonstration of Addressable Microstimulators Powered by Rectification of Epidermically Applied Currents for Miniaturized Neuroprostheses.
Becerra-Fajardo L; Ivorra A
PLoS One; 2015; 10(7):e0131666. PubMed ID: 26147771
[TBL] [Abstract][Full Text] [Related]
8. Demonstration of 2-mm-Thick Microcontrolled Injectable Stimulators Based on Rectification of High Frequency Current Bursts.
Becerra Fajardo L; Schmidbauer M; Ivorra A
IEEE Trans Neural Syst Rehabil Eng; 2017 Aug; 25(8):1343-1352. PubMed ID: 27845663
[TBL] [Abstract][Full Text] [Related]
9. Remote electrical stimulation by means of implanted rectifiers.
Ivorra A
PLoS One; 2011; 6(8):e23456. PubMed ID: 21850274
[TBL] [Abstract][Full Text] [Related]
10. First-in-human demonstration of floating EMG sensors and stimulators wirelessly powered and operated by volume conduction.
Becerra-Fajardo L; Minguillon J; Krob MO; Rodrigues C; González-Sánchez M; Megía-García Á; Galán CR; Henares FG; Comerma A; Del-Ama AJ; Gil-Agudo A; Grandas F; Schneider-Ickert A; Barroso FO; Ivorra A
J Neuroeng Rehabil; 2024 Jan; 21(1):4. PubMed ID: 38172975
[TBL] [Abstract][Full Text] [Related]
11. Towards addressable wireless microstimulators based on electronic rectification of epidermically applied currents.
Becerra-Fajardo L; Ivorra A
Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():3973-6. PubMed ID: 25570862
[TBL] [Abstract][Full Text] [Related]
12. A flexible super-capacitive solid-state power supply for miniature implantable medical devices.
Meng C; Gall OZ; Irazoqui PP
Biomed Microdevices; 2013 Dec; 15(6):973-83. PubMed ID: 23832644
[TBL] [Abstract][Full Text] [Related]
13. Injectable Biomedical Devices for Sensing and Stimulating Internal Body Organs.
Jung YH; Kim JU; Lee JS; Shin JH; Jung W; Ok J; Kim TI
Adv Mater; 2020 Apr; 32(16):e1907478. PubMed ID: 32104960
[TBL] [Abstract][Full Text] [Related]
14. ASIC Design for Wireless Surgical MEMS Device and Instrumentation.
To G; Qu W; Mahfouz MR
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5892-5. PubMed ID: 17946347
[TBL] [Abstract][Full Text] [Related]
15. Novel 3D-printed Electrodes for Implantable Biopotential Monitoring.
Ahmmed P; Reynolds J; Hamada S; Regmi P; Bozkurt A
Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():7120-7123. PubMed ID: 34892742
[TBL] [Abstract][Full Text] [Related]
16. Implantable 9-channel telemetry system for in vivo load measurements with orthopedic implants.
Graichen F; Arnold R; Rohlmann A; Bergmann G
IEEE Trans Biomed Eng; 2007 Feb; 54(2):253-61. PubMed ID: 17278582
[TBL] [Abstract][Full Text] [Related]
17. Optimizing Volumetric Efficiency and Backscatter Communication in Biosensing Ultrasonic Implants.
Ghanbari MM; Muller R
IEEE Trans Biomed Circuits Syst; 2020 Dec; 14(6):1381-1392. PubMed ID: 33095711
[TBL] [Abstract][Full Text] [Related]
18. An implantable telemetry platform system for in vivo monitoring of physiological parameters.
Valdastri P; Menciassi A; Arena A; Caccamo C; Dario P
IEEE Trans Inf Technol Biomed; 2004 Sep; 8(3):271-8. PubMed ID: 15484432
[TBL] [Abstract][Full Text] [Related]
19. Wireless Interrogation of Implantable SAW Sensors.
Zou L; McLeod C; Bahmanyar MR
IEEE Trans Biomed Eng; 2020 May; 67(5):1409-1417. PubMed ID: 31449002
[TBL] [Abstract][Full Text] [Related]
20. A 30 $\mu\text{W}$ Remotely Powered Local Temperature Monitoring Implantable System.
Ghanad MA; Green MM; Dehollain C
IEEE Trans Biomed Circuits Syst; 2017 Feb; 11(1):54-63. PubMed ID: 27514065
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]