These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 32756019)

  • 1. BrachyView: development of an algorithm for real-time automatic LDR brachytherapy seed detection.
    Brennen T; Galli L; Cutajar DL; Alnaghy S; Bucci J; Bece A; Enari K; Favoino M; Carriero M; Tartaglia M; Archer J; Lerch M; Rosenfeld AB; Petasecca M
    Phys Med Biol; 2020 Nov; 65(21):215015. PubMed ID: 32756019
    [TBL] [Abstract][Full Text] [Related]  

  • 2. BrachyView: Reconstruction of seed positions and volume of an LDR prostate brachytherapy patient plan using a baseline subtraction algorithm.
    Brennen T; Cutajar DL; Alnaghy S; Bucci J; Bece A; Enari K; Favoino M; Carriero F; Tartaglia M; Galli L; Lerch M; Rosenfeld AB; Petasecca M
    Phys Med; 2019 Oct; 66():66-76. PubMed ID: 31563727
    [TBL] [Abstract][Full Text] [Related]  

  • 3. BrachyView: proof-of-principle of a novel in-body gamma camera for low dose-rate prostate brachytherapy.
    Petasecca M; Loo KJ; Safavi-Naeini M; Han Z; Metcalfe PE; Meikle S; Pospisil S; Jakubek J; Bucci JA; Zaider M; Lerch ML; Qi Y; Rosenfeld AB
    Med Phys; 2013 Apr; 40(4):041709. PubMed ID: 23556879
    [TBL] [Abstract][Full Text] [Related]  

  • 4. BrachyView: Combining LDR seed positions with transrectal ultrasound imaging in a prostate gel phantom.
    Alnaghy S; Cutajar DL; Bucci JA; Enari K; Safavi-Naeini M; Favoino M; Tartaglia M; Carriero F; Jakubek J; Pospisil S; Lerch M; Rosenfeld AB; Petasecca M
    Phys Med; 2017 Feb; 34():55-64. PubMed ID: 28118951
    [TBL] [Abstract][Full Text] [Related]  

  • 5. EM-enhanced US-based seed detection for prostate brachytherapy.
    Dehghan E; Bharat S; Kung C; Bonillas A; Beaulieu L; Pouliot J; Kruecker J
    Med Phys; 2018 Jun; 45(6):2357-2368. PubMed ID: 29604086
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Clinical implementation of a digital tomosynthesis-based seed reconstruction algorithm for intraoperative postimplant dose evaluation in low dose rate prostate brachytherapy.
    Brunet-Benkhoucha M; Verhaegen F; Lassalle S; Béliveau-Nadeau D; Reniers B; Donath D; Taussky D; Carrier JF
    Med Phys; 2009 Nov; 36(11):5235-44. PubMed ID: 19994534
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prostate brachytherapy seed localization by analysis of multiple projections: identifying and addressing the seed overlap problem.
    Su Y; Davis BJ; Herman MG; Robb RA
    Med Phys; 2004 May; 31(5):1277-87. PubMed ID: 15191320
    [TBL] [Abstract][Full Text] [Related]  

  • 8. MRI-based automated detection of implanted low dose rate (LDR) brachytherapy seeds using quantitative susceptibility mapping (QSM) and unsupervised machine learning (ML).
    Nosrati R; Soliman A; Safigholi H; Hashemi M; Wronski M; Morton G; Pejović-Milić A; Stanisz G; Song WY
    Radiother Oncol; 2018 Dec; 129(3):540-547. PubMed ID: 30243670
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Matching and reconstruction of brachytherapy seeds using the Hungarian algorithm (MARSHAL).
    Jain AK; Zhou Y; Mustufa T; Burdette EC; Chirikjian GS; Fichtinger G
    Med Phys; 2005 Nov; 32(11):3475-92. PubMed ID: 16372418
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.
    Pokhrel D; Murphy MJ; Todor DA; Weiss E; Williamson JF
    Med Phys; 2011 Jan; 38(1):474-86. PubMed ID: 21361216
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An automatic seed finder for brachytherapy CT postplans based on the Hough transform.
    Holupka EJ; Meskell PM; Burdette EC; Kaplan ID
    Med Phys; 2004 Sep; 31(9):2672-9. PubMed ID: 15487750
    [TBL] [Abstract][Full Text] [Related]  

  • 12. BrachyView, a novel inbody imaging system for HDR prostate brachytherapy: design and Monte Carlo feasibility study.
    Safavi-Naeini M; Han Z; Cutajar D; Guatelli S; Petasecca M; Lerch ML; Franklin DR; Jakubek J; Pospisil S; Bucci J; Zaider M; Rosenfeld AB
    Med Phys; 2013 Jul; 40(7):071715. PubMed ID: 23822419
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Segmentation of iodine brachytherapy implants in fluoroscopy.
    Moult E; Fichtinger G; Morris WJ; Salcudean SE; Dehghan E; Fallavollita P
    Int J Comput Assist Radiol Surg; 2012 Nov; 7(6):871-9. PubMed ID: 22447486
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility of an MRI-only workflow for postimplant dosimetry of low-dose-rate prostate brachytherapy: Transition from phantoms to patients.
    Nosrati R; Song WY; Wronski M; Pejović-Milić A; Morton G; Stanisz GJ
    Brachytherapy; 2019; 18(6):863-874. PubMed ID: 31337542
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prostate brachytherapy postimplant dosimetry: automatic plan reconstruction of stranded implants.
    Chng N; Spadinger I; Morris WJ; Usmani N; Salcudean S
    Med Phys; 2011 Jan; 38(1):327-42. PubMed ID: 21361201
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Operator-free, film-based 3D seed reconstruction in brachytherapy.
    Todor DA; Cohen GN; Amols HI; Zaider M
    Phys Med Biol; 2002 Jun; 47(12):2031-48. PubMed ID: 12118599
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intraoperative fluoroscopic dose assessment in prostate brachytherapy patients.
    Reed DR; Wallner KE; Narayanan S; Sutlief SG; Ford EC; Cho PS
    Int J Radiat Oncol Biol Phys; 2005 Sep; 63(1):301-7. PubMed ID: 16111600
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intraoperative dynamic dose optimization in permanent prostate implants.
    Lee EK; Zaider M
    Int J Radiat Oncol Biol Phys; 2003 Jul; 56(3):854-61. PubMed ID: 12788195
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Real-time intraoperative evaluation of implant quality and dose correction during prostate brachytherapy consistently improves target coverage using a novel image fusion and optimization program.
    Zelefsky MJ; Cohen GN; Taggar AS; Kollmeier M; McBride S; Mageras G; Zaider M
    Pract Radiat Oncol; 2017; 7(5):319-324. PubMed ID: 28377139
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Machine learning and registration for automatic seed localization in 3D US images for prostate brachytherapy.
    Younes H; Troccaz J; Voros S
    Med Phys; 2021 Mar; 48(3):1144-1156. PubMed ID: 33511658
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.