256 related articles for article (PubMed ID: 32758051)
1. Oversizing Increases Pacemaker Implantation Rate After Sutureless Minimally Invasive Aortic Valve Replacement.
Geršak B; Glauber M; Bouchard D; Jug J; Solinas M
Innovations (Phila); 2020; 15(5):449-455. PubMed ID: 32758051
[TBL] [Abstract][Full Text] [Related]
2. Avoiding oversizing in sutureless valves leads to lower transvalvular gradients and less permanent pacemaker implants postoperatively.
Szecel D; Lamberigts M; Rega F; Verbrugghe P; Dubois C; Meuris B
Interact Cardiovasc Thorac Surg; 2022 Jul; 35(2):. PubMed ID: 35689614
[TBL] [Abstract][Full Text] [Related]
3. Increased Gradients After Aortic Valve Replacement With the Perceval Valve: The Role of Oversizing.
Cerillo AG; Amoretti F; Mariani M; Cigala E; Murzi M; Gasbarri T; Solinas M; Chiappino D
Ann Thorac Surg; 2018 Jul; 106(1):121-128. PubMed ID: 29408354
[TBL] [Abstract][Full Text] [Related]
4. TRANSFORM (Multicenter Experience With Rapid Deployment Edwards INTUITY Valve System for Aortic Valve Replacement) US clinical trial: Performance of a rapid deployment aortic valve.
Barnhart GR; Accola KD; Grossi EA; Woo YJ; Mumtaz MA; Sabik JF; Slachman FN; Patel HJ; Borger MA; Garrett HE; Rodriguez E; McCarthy PM; Ryan WH; Duhay FG; Mack MJ; Chitwood WR;
J Thorac Cardiovasc Surg; 2017 Feb; 153(2):241-251.e2. PubMed ID: 27817951
[TBL] [Abstract][Full Text] [Related]
5. Surgical aortic valve replacement with new-generation bioprostheses: Sutureless versus rapid-deployment.
D'Onofrio A; Salizzoni S; Filippini C; Tessari C; Bagozzi L; Messina A; Troise G; Tomba MD; Rambaldini M; Dalén M; Alamanni F; Massetti M; Mignosa C; Russo C; Salvador L; Di Bartolomeo R; Maselli D; De Paulis R; Alfieri O; De Filippo CM; Portoghese M; Bortolotti U; Rinaldi M; Gerosa G
J Thorac Cardiovasc Surg; 2020 Feb; 159(2):432-442.e1. PubMed ID: 31213376
[TBL] [Abstract][Full Text] [Related]
6. Minimally Invasive Aortic Valve Replacement with Sutureless Valves: Results From an International Prospective Registry.
Glauber M; Di Bacco L; Cuenca J; Di Bartolomeo R; Baghai M; Zakova D; Fischlein T; Troise G; Viganò G; Solinas M
Innovations (Phila); 2020; 15(2):120-130. PubMed ID: 31875777
[TBL] [Abstract][Full Text] [Related]
7. Tackling the Issue of High Postoperative Pacemaker Implantation Rates in Sutureless Aortic Valve Replacement: Should Balloon Inflation be Removed from the Implantation Method of the Perceval Prosthesis?
Charles Blouin M; Bouhout I; Demers P; Carrier M; Perrault L; Lamarche Y; El-Hamamsy I; Bouchard D
J Heart Valve Dis; 2017 May; 26(3):247-254. PubMed ID: 29092107
[TBL] [Abstract][Full Text] [Related]
8. Aortic valve replacement through right anterior minithoracotomy: can sutureless technology improve clinical outcomes?
Gilmanov D; Miceli A; Ferrarini M; Farneti P; Murzi M; Solinas M; Glauber M
Ann Thorac Surg; 2014 Nov; 98(5):1585-92. PubMed ID: 25200732
[TBL] [Abstract][Full Text] [Related]
9. Pacemaker need after sutureless aortic valve replacement: the role of the learning curve.
Mikus E; Calvi S; Tavazzi L; Brega C; Tripodi A; Pin M; Manfrini M; Zucchetta F; Tenti E; Albertini A
J Cardiovasc Med (Hagerstown); 2021 Feb; 22(2):133-138. PubMed ID: 33021519
[TBL] [Abstract][Full Text] [Related]
10. Predictors of Pacemaker Insertion Post-Sutureless (Perceval) Aortic Valve Implantation.
Brookes JDL; Mathew M; Brookes EM; Jaya JS; Almeida AA; Smith JA
Heart Lung Circ; 2021 Jun; 30(6):917-921. PubMed ID: 33309876
[TBL] [Abstract][Full Text] [Related]
11. Sutureless aortic valve replacement with Perceval bioprosthesis: are there predicting factors for postoperative pacemaker implantation?
Vogt F; Pfeiffer S; Dell'Aquila AM; Fischlein T; Santarpino G
Interact Cardiovasc Thorac Surg; 2016 Mar; 22(3):253-8. PubMed ID: 26614526
[TBL] [Abstract][Full Text] [Related]
12. Rapid deployment aortic valve replacement through anterior right thoracotomy: Clinical outcomes and haemodynamic performance.
Sabry H; Baltabaeva A; Gkikas A; Valencia O; Sarri G; Mirsadraee S; Mittal T; Bahrami T
J Card Surg; 2020 Jul; 35(7):1420-1424. PubMed ID: 32340065
[TBL] [Abstract][Full Text] [Related]
13. The Perceval Sutureless Bioprosthetic Aortic Valve: Evolution of Surgical Valve Technology.
Fialka NM; El-Andari R; Wang S; Dokollari A; Kent WDT; Fatehi Hassanabad A
Innovations (Phila); 2024; 19(2):125-135. PubMed ID: 38465600
[TBL] [Abstract][Full Text] [Related]
14. Sutureless Perceval Aortic Valve Versus Conventional Stented Bioprostheses: Meta-Analysis of Postoperative and Midterm Results in Isolated Aortic Valve Replacement.
Meco M; Montisci A; Miceli A; Panisi P; Donatelli F; Cirri S; Ferrarini M; Lio A; Glauber M
J Am Heart Assoc; 2018 Feb; 7(4):. PubMed ID: 29453309
[TBL] [Abstract][Full Text] [Related]
15. Perceval Sutureless Aortic Valve Implantation: Midterm Outcomes.
Szecel D; Eurlings R; Rega F; Verbrugghe P; Meuris B
Ann Thorac Surg; 2021 Apr; 111(4):1331-1337. PubMed ID: 32866479
[TBL] [Abstract][Full Text] [Related]
16. Sutureless implantation of the perceval s aortic valve prosthesis through right anterior minithoracotomy.
Gilmanov D; Miceli A; Bevilacqua S; Farneti P; Solinas M; Ferrarini M; Glauber M
Ann Thorac Surg; 2013 Dec; 96(6):2101-8. PubMed ID: 24054468
[TBL] [Abstract][Full Text] [Related]
17. Minimally invasive aortic valve replacement with sutureless and rapid deployment valves: a report from an international registry (Sutureless and Rapid Deployment International Registry)†.
Berretta P; Andreas M; Carrel TP; Solinas M; Teoh K; Fischlein T; Santarpino G; Folliguet T; Villa E; Meuris B; Mignosa C; Martinelli G; Misfeld M; Glauber M; Kappert U; Savini C; Shrestha M; Phan K; Albertini A; Yan T; Di Eusanio M
Eur J Cardiothorac Surg; 2019 Oct; 56(4):793-799. PubMed ID: 30820549
[TBL] [Abstract][Full Text] [Related]
18. Minimally invasive redo aortic valve replacement with a sutureless valve implant.
Paparella D; De Santis A
Multimed Man Cardiothorac Surg; 2021 Mar; 2021():. PubMed ID: 33691045
[TBL] [Abstract][Full Text] [Related]
19. Recent improvement in operative techniques lead to lower pacemaker rate after Perceval implant.
Fabre O; Radutoiu M; Carjaliu I; Rebet O; Gautier L; Hysi I
Interact Cardiovasc Thorac Surg; 2022 Jul; 35(2):. PubMed ID: 35751610
[TBL] [Abstract][Full Text] [Related]
20.
; ; . PubMed ID:
[No Abstract] [Full Text] [Related]
[Next] [New Search]