These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries. McCowan PM; McCurdy BM Med Phys; 2016 Jan; 43(1):254. PubMed ID: 26745918 [TBL] [Abstract][Full Text] [Related]
4. Pixel response-based EPID dosimetry for patient specific QA. Han B; Ding A; Lu M; Xing L J Appl Clin Med Phys; 2017 Jan; 18(1):9-17. PubMed ID: 28291939 [TBL] [Abstract][Full Text] [Related]
5. Analysis of a free-running synchronization artifact correction for MV-imaging with aSi:H flat panels. Mooslechner M; Mitterlechner B; Weichenberger H; Huber S; Sedlmayer F; Deutschmann H Med Phys; 2013 Mar; 40(3):031906. PubMed ID: 23464321 [TBL] [Abstract][Full Text] [Related]
6. Characterization of Gas Electron Multiplier-based detector for external beam radiation therapy dosimetry. Muñoz D; Olaciregui-Ruiz I; Norberg G; van der Heide UA; Mans A Med Phys; 2021 Apr; 48(4):1931-1940. PubMed ID: 33440024 [TBL] [Abstract][Full Text] [Related]
7. Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging. Rowshanfarzad P; Sabet M; O'Connor DJ; McCowan PM; McCurdy BM; Greer PB Med Phys; 2012 Feb; 39(2):623-35. PubMed ID: 22320771 [TBL] [Abstract][Full Text] [Related]
8. A portal dosimetry dose prediction method based on collapsed cone algorithm using the clinical beam model. Martínez Ortega J; Gómez González N; Castro Tejero P; Pinto Monedero M; Tolani NB; Núñez Martín L; Sánchez Montero R Med Phys; 2017 Jan; 44(1):333-341. PubMed ID: 28102946 [TBL] [Abstract][Full Text] [Related]
9. Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device. Greer PB Med Phys; 2007 Oct; 34(10):3815-24. PubMed ID: 17985627 [TBL] [Abstract][Full Text] [Related]
10. Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification. McDermott LN; Wendling M; van Asselen B; Stroom J; Sonke JJ; van Herk M; Mijnheer BJ Med Phys; 2006 Oct; 33(10):3921-30. PubMed ID: 17089854 [TBL] [Abstract][Full Text] [Related]
11. Feasibility study on inverse four-dimensional dose reconstruction using the continuous dose-image of EPID. Yeo IJ; Jung JW; Yi BY; Kim JO Med Phys; 2013 May; 40(5):051702. PubMed ID: 23635250 [TBL] [Abstract][Full Text] [Related]
12. A Swiss cheese error detection method for real-time EPID-based quality assurance and error prevention. Passarge M; Fix MK; Manser P; Stampanoni MF; Siebers JV Med Phys; 2017 Apr; 44(4):1212-1223. PubMed ID: 28134989 [TBL] [Abstract][Full Text] [Related]
13. A novel approach to SBRT patient quality assurance using EPID-based real-time transit dosimetry : A step to QA with in vivo EPID dosimetry. Moustakis C; Ebrahimi Tazehmahalleh F; Elsayad K; Fezeu F; Scobioala S Strahlenther Onkol; 2020 Feb; 196(2):182-192. PubMed ID: 31925465 [TBL] [Abstract][Full Text] [Related]
14. Low-cost flexible thin-film detector for medical dosimetry applications. Zygmanski P; Abkai C; Han Z; Shulevich Y; Menichelli D; Hesser J J Appl Clin Med Phys; 2014 Mar; 15(2):4454. PubMed ID: 24710432 [TBL] [Abstract][Full Text] [Related]
15. Daily QA of linear accelerators using only EPID and OBI. Sun B; Goddu SM; Yaddanapudi S; Noel C; Li H; Cai B; Kavanaugh J; Mutic S Med Phys; 2015 Oct; 42(10):5584-94. PubMed ID: 26429233 [TBL] [Abstract][Full Text] [Related]
16. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy. Ding A; Xing L; Han B Med Phys; 2015 Jul; 42(7):4190-8. PubMed ID: 26133618 [TBL] [Abstract][Full Text] [Related]
17. An investigation of gantry angle data accuracy for cine-mode EPID images acquired during arc IMRT. McCowan PM; Rickey DW; Rowshanfarzad P; Greer PB; Ansbacher W; McCurdy BM J Appl Clin Med Phys; 2014 Jan; 15(1):4507. PubMed ID: 24423849 [TBL] [Abstract][Full Text] [Related]
18. A simulation study of ionizing radiation acoustic imaging (iRAI) as a real-time dosimetric technique for ultra-high dose rate radiotherapy (UHDR-RT). Ba Sunbul NH; Zhang W; Oraiqat I; Litzenberg DW; Lam KL; Cuneo K; Moran JM; Carson PL; Wang X; Clarke SD; Matuszak MM; Pozzi SA; El Naqa I Med Phys; 2021 Oct; 48(10):6137-6151. PubMed ID: 34431520 [TBL] [Abstract][Full Text] [Related]
19. Fiducial marker and marker-less soft-tissue detection using fast MV fluoroscopy on a new generation EPID: investigating the influence of pulsing artifacts and artifact suppression techniques. Poels K; Verellen D; Van de Vondel I; El Mazghari R; Depuydt T; De Ridder M Med Phys; 2014 Oct; 41(10):101911. PubMed ID: 25281963 [TBL] [Abstract][Full Text] [Related]
20. An error detection method for real-time EPID-based treatment delivery quality assurance. Alves VGL; Ahmed M; Aliotta E; Choi W; Siebers JV Med Phys; 2021 Feb; 48(2):569-578. PubMed ID: 33314247 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]