These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Advanced modeling strategy for the analysis of heart valve leaflet tissue mechanics using high-order finite element method. Mohammadi H; Bahramian F; Wan W Med Eng Phys; 2009 Nov; 31(9):1110-7. PubMed ID: 19773193 [TBL] [Abstract][Full Text] [Related]
4. Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve. Xuan Y; Krishnan K; Ye J; Dvir D; Guccione JM; Ge L; Tseng EE J Thorac Cardiovasc Surg; 2017 May; 153(5):1065-1073. PubMed ID: 28108064 [TBL] [Abstract][Full Text] [Related]
5. Finite element modeling of mitral valve dynamic deformation using patient-specific multi-slices computed tomography scans. Wang Q; Sun W Ann Biomed Eng; 2013 Jan; 41(1):142-53. PubMed ID: 22805982 [TBL] [Abstract][Full Text] [Related]
6. An inverse modeling approach for stress estimation in mitral valve anterior leaflet valvuloplasty for in-vivo valvular biomaterial assessment. Lee CH; Amini R; Gorman RC; Gorman JH; Sacks MS J Biomech; 2014 Jun; 47(9):2055-63. PubMed ID: 24275434 [TBL] [Abstract][Full Text] [Related]
7. Effect of mitral annuloplasty device shape and size on leaflet and myofiber stress following repair of posterior leaflet prolapse: a patient-specific finite element simulation. Morrel WG; Ge L; Zhang Z; Grossi EA; Guccione JM; Ratcliffe MB J Heart Valve Dis; 2014 Nov; 23(6):727-34. PubMed ID: 25790620 [TBL] [Abstract][Full Text] [Related]
8. A finite element model on effects of impact load and cavitation on fatigue crack propagation in mechanical bileaflet aortic heart valve. Mohammadi H; Klassen RJ; Wan WK Proc Inst Mech Eng H; 2008 Oct; 222(7):1115-25. PubMed ID: 19024159 [TBL] [Abstract][Full Text] [Related]
9. Characterization of three-dimensional anisotropic heart valve tissue mechanical properties using inverse finite element analysis. Abbasi M; Barakat MS; Vahidkhah K; Azadani AN J Mech Behav Biomed Mater; 2016 Sep; 62():33-44. PubMed ID: 27173827 [TBL] [Abstract][Full Text] [Related]
10. Reduced leaflet stress in the stentless quadrileaflet mitral valve: a finite element model. Wang JG; Kuai XC; Ren BQ; Gong GF; Zhou XM PLoS One; 2013; 8(7):e67683. PubMed ID: 23844060 [TBL] [Abstract][Full Text] [Related]
11. Altered collagen concentration in mitral valve leaflets: biochemical and finite element analysis. Kunzelman KS; Quick DW; Cochran RP Ann Thorac Surg; 1998 Dec; 66(6 Suppl):S198-205. PubMed ID: 9930448 [TBL] [Abstract][Full Text] [Related]
12. Neochord placement versus triangular resection in mitral valve repair: A finite element model. Morgan AE; Pantoja JL; Grossi EA; Ge L; Weinsaft JW; Ratcliffe MB J Surg Res; 2016 Nov; 206(1):98-105. PubMed ID: 27916382 [TBL] [Abstract][Full Text] [Related]
13. Biomechanical evaluation of the pathophysiologic developmental mechanisms of mitral valve prolapse: effect of valvular morphologic alteration. Choi A; McPherson DD; Kim H Med Biol Eng Comput; 2016 May; 54(5):799-809. PubMed ID: 26307201 [TBL] [Abstract][Full Text] [Related]
14. Functional and Biomechanical Effects of the Edge-to-Edge Repair in the Setting of Mitral Regurgitation: Consolidated Knowledge and Novel Tools to Gain Insight into Its Percutaneous Implementation. Sturla F; Redaelli A; Puppini G; Onorati F; Faggian G; Votta E Cardiovasc Eng Technol; 2015 Jun; 6(2):117-40. PubMed ID: 26577231 [TBL] [Abstract][Full Text] [Related]
15. Finite element modeling of mitral leaflet tissue using a layered shell approximation. Wenk JF; Ratcliffe MB; Guccione JM Med Biol Eng Comput; 2012 Oct; 50(10):1071-9. PubMed ID: 22971896 [TBL] [Abstract][Full Text] [Related]
16. Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents. Krucinski S; Vesely I; Dokainish MA; Campbell G J Biomech; 1993 Aug; 26(8):929-43. PubMed ID: 8349718 [TBL] [Abstract][Full Text] [Related]
17. Prosthetic aortic heart valves: modeling and design. Mohammadi H; Mequanint K Med Eng Phys; 2011 Mar; 33(2):131-47. PubMed ID: 20971672 [TBL] [Abstract][Full Text] [Related]
18. Mechanics of the mitral valve: a critical review, an in vivo parameter identification, and the effect of prestrain. Rausch MK; Famaey N; Shultz TO; Bothe W; Miller DC; Kuhl E Biomech Model Mechanobiol; 2013 Oct; 12(5):1053-71. PubMed ID: 23263365 [TBL] [Abstract][Full Text] [Related]
20. Quantification and comparison of the mechanical properties of four human cardiac valves. Pham T; Sulejmani F; Shin E; Wang D; Sun W Acta Biomater; 2017 May; 54():345-355. PubMed ID: 28336153 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]