213 related articles for article (PubMed ID: 32766226)
1. Biomechanical Evaluation and the Assisted 3D Printed Model in the Patient-Specific Preoperative Planning for Thoracic Spinal Tuberculosis: A Finite Element Analysis.
Wang B; Ke W; Hua W; Zeng X; Yang C
Front Bioeng Biotechnol; 2020; 8():807. PubMed ID: 32766226
[TBL] [Abstract][Full Text] [Related]
2. Bilateral pedicle screw fixation provides superior biomechanical stability in transforaminal lumbar interbody fusion: a finite element study.
Ambati DV; Wright EK; Lehman RA; Kang DG; Wagner SC; Dmitriev AE
Spine J; 2015 Aug; 15(8):1812-22. PubMed ID: 24983669
[TBL] [Abstract][Full Text] [Related]
3. [Efficacy of 3D print guide technique in one stage posterior approach for the treatment of cervical and thoracic tuberculosis with kyphosis].
Shaxika N; Sun ZG; Yuan H; Wang H
Zhonghua Yi Xue Za Zhi; 2017 Nov; 97(43):3421-3427. PubMed ID: 29179285
[No Abstract] [Full Text] [Related]
4. Treatment of thoracolumbar burst fractures by short-segment pedicle screw fixation using a combination of two additional pedicle screws and vertebroplasty at the level of the fracture: a finite element analysis.
Liao JC; Chen WP; Wang H
BMC Musculoskelet Disord; 2017 Jun; 18(1):262. PubMed ID: 28619021
[TBL] [Abstract][Full Text] [Related]
5. The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis.
Akamaru T; Kawahara N; Sakamoto J; Yoshida A; Murakami H; Hato T; Awamori S; Oda J; Tomita K
Spine (Phila Pa 1976); 2005 Dec; 30(24):2783-7. PubMed ID: 16371903
[TBL] [Abstract][Full Text] [Related]
6. The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series.
Yue JJ; Sossan A; Selgrath C; Deutsch LS; Wilkens K; Testaiuti M; Gabriel JP
Spine (Phila Pa 1976); 2002 Dec; 27(24):2782-7. PubMed ID: 12486347
[TBL] [Abstract][Full Text] [Related]
7. Comparison of the biomechanical effect of pedicle-based dynamic stabilization: a study using finite element analysis.
Jahng TA; Kim YE; Moon KY
Spine J; 2013 Jan; 13(1):85-94. PubMed ID: 23266148
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical evaluation of diagonal fixation in pedicle screw instrumentation.
Lim TH; Kim JG; Fujiwara A; Yoon TT; Lee SC; Ha JW; An HS
Spine (Phila Pa 1976); 2001 Nov; 26(22):2498-503. PubMed ID: 11707718
[TBL] [Abstract][Full Text] [Related]
9. [3D printing technology assisted the preoperative planning and application value in adult kyphoscoliosis deformity].
Jiang WL; Niu GQ; Zhou G; Chen H; Liu T; Nie H; Liu LT; Li C; Zhou QK
Zhongguo Gu Shang; 2020 Feb; 33(2):99-105. PubMed ID: 32133805
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical analysis on of anterior transpedicular screw-fixation after two-level cervical corpectomy using finite element method.
Zhao L; Chen J; Liu J; Elsamaloty L; Liu X; Li J; Elgafy H; Zhang J; Wang L
Clin Biomech (Bristol, Avon); 2018 Dec; 60():76-82. PubMed ID: 30326320
[TBL] [Abstract][Full Text] [Related]
11. The effect of screw tunnels on the biomechanical stability of vertebral body after pedicle screws removal: a finite element analysis.
Liu JM; Zhang Y; Zhou Y; Chen XY; Huang SH; Hua ZK; Liu ZL
Int Orthop; 2017 Jun; 41(6):1183-1187. PubMed ID: 28353052
[TBL] [Abstract][Full Text] [Related]
12. T9 versus T10 as the upper instrumented vertebra for correction of adult deformity-rationale and recommendations.
Hey HWD; Tan KA; Neo CS; Lau ET; Choong DA; Lau LL; Liu GK; Wong HK
Spine J; 2017 May; 17(5):615-621. PubMed ID: 27856380
[TBL] [Abstract][Full Text] [Related]
13. Biomechanical advantages of robot-assisted pedicle screw fixation in posterior lumbar interbody fusion compared with freehand technique in a prospective randomized controlled trial-perspective for patient-specific finite element analysis.
Kim HJ; Kang KT; Park SC; Kwon OH; Son J; Chang BS; Lee CK; Yeom JS; Lenke LG
Spine J; 2017 May; 17(5):671-680. PubMed ID: 27867080
[TBL] [Abstract][Full Text] [Related]
14. Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: special references of hook configurations and pedicle screws.
An HS; Singh K; Vaccaro AR; Wang G; Yoshida H; Eck J; McGrady L; Lim TH
Spine (Phila Pa 1976); 2004 Feb; 29(3):257-62. PubMed ID: 14752346
[TBL] [Abstract][Full Text] [Related]
15. Biomechanical Stability Before and After Graft Fusion with Unilateral and Bilateral Pedicle Screw Fixation: Finite Element Study.
Li J; Wang W; Zuo R; Zhou Y
World Neurosurg; 2019 Mar; 123():e228-e234. PubMed ID: 30481621
[TBL] [Abstract][Full Text] [Related]
16. Finite element method-based study of pedicle screw-bone connection in pullout test and physiological spinal loads.
Xu M; Yang J; Lieberman IH; Haddas R
Med Eng Phys; 2019 May; 67():11-21. PubMed ID: 30879945
[TBL] [Abstract][Full Text] [Related]
17. [Biomechanical study of different kinds of internal fixation for the typeⅠ Hangman fracture, type Ⅱ odontoid fracture and the C(2/3) disc injury: a finite-element analysis].
Hu Y; Dong WX; Xu JZ; Yuan ZS; Sun XY; Zhu BK; Lai OJ; Chen XG; Zhao BJ
Zhonghua Yi Xue Za Zhi; 2018 Aug; 98(31):2489-2495. PubMed ID: 30139001
[No Abstract] [Full Text] [Related]
18. How to Reduce Stress on the Pedicle Screws in Thoracic Spine? Importance of Screw Trajectory: A Finite Element Analysis.
Guvenc Y; Akyoldas G; Senturk S; Erbulut D; Yaman O; Ozer AF
Turk Neurosurg; 2019; 29(1):20-25. PubMed ID: 29368324
[TBL] [Abstract][Full Text] [Related]
19. Biomechanics of transvertebral screw fixation in the thoracic spine: an in vitro study.
Rodriguez-Martinez NG; Savardekar A; Nottmeier EW; Pirris S; Reyes PM; Newcomb AG; Mendes GA; Kalb S; Theodore N; Crawford NR
J Neurosurg Spine; 2016 Aug; 25(2):187-92. PubMed ID: 27035506
[TBL] [Abstract][Full Text] [Related]
20. Biomechanical comparison of posterior intermediate screw fixation techniques with hybrid monoaxial and polyaxial pedicle screws in the treatment of thoracolumbar burst fracture: a finite element study.
Liu H; Wang H; Liu J; Li C; Zhou Y; Xiang L
J Orthop Surg Res; 2019 May; 14(1):122. PubMed ID: 31068193
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]