These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

152 related articles for article (PubMed ID: 32766426)

  • 1. Brief Bubble and Intermittent Surface Oxygenation Is a Simple and Effective Alternative for Membrane Oxygenation During Hypothermic Machine Perfusion in Kidneys.
    Darius T; Vergauwen M; Mueller M; Aydin S; Dutkowski P; Gianello P; Mourad M
    Transplant Direct; 2020 Jul; 6(7):e571. PubMed ID: 32766426
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Brief O
    Darius T; Vergauwen M; Smith T; Gerin I; Joris V; Mueller M; Aydin S; Muller X; Schlegel A; Nath J; Ludwig C; Dessy C; Many MC; Bommer G; Dutkowski P; Gianello P; Mourad M
    Am J Transplant; 2020 Aug; 20(8):2030-2043. PubMed ID: 32012434
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intermittent Surface Oxygenation Results in Similar Mitochondrial Protection and Maintenance of Aerobic Metabolism as Compared to Continuous Oxygenation during Hypothermic Machine Kidney Machine Perfusion.
    Darius T; Vergauwen M; Maistriaux L; Evrard R; Schlegel A; Mueller M; O'Neil D; Southam A; Aydin S; Devresse A; De Meyer M; Gianello P; Ludwig C; Dutkowski P; Mourad M
    J Clin Med; 2023 May; 12(11):. PubMed ID: 37297930
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Influence of Different Partial Pressures of Oxygen During Continuous Hypothermic Machine Perfusion in a Pig Kidney Ischemia-reperfusion Autotransplant Model.
    Darius T; Vergauwen M; Smith TB; Patel K; Craps J; Joris V; Aydin S; Ury B; Buemi A; De Meyer M; Nath J; Ludwig C; Dessy C; Many MC; Gianello P; Mourad M
    Transplantation; 2020 Apr; 104(4):731-743. PubMed ID: 31764761
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect on early renal function of various dynamic preservation strategies in a preclinical pig ischemia-reperfusion autotransplant model.
    Darius T; Gianello P; Vergauwen M; Mourad N; Buemi A; De Meyer M; Mourad M
    Am J Transplant; 2019 Mar; 19(3):752-762. PubMed ID: 30171799
    [TBL] [Abstract][Full Text] [Related]  

  • 6. First clinical kidney transplantation series using brief bubble and direct surface oxygenation as alternative for membrane oxygenation during hypothermic machine perfusion.
    Darius T; Devresse A; Buemi A; Kanaan N; De Meyer M; Mourad M
    Artif Organs; 2023 Apr; 47(4):777-785. PubMed ID: 36461753
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Novel oxygenation technique for hypothermic machine perfusion of liver grafts: Validation in porcine Donation after Cardiac Death (DCD) liver model.
    Panayotova GG; Rosado J; Paterno F; Deo D; Dikdan G; McCarty MA; Arrington B; Giudice A; Fano A; Dhaduk N; Lunsford KE; Rao P; Guarrera JV
    Am J Surg; 2020 Nov; 220(5):1270-1277. PubMed ID: 32892979
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Oxygenated versus standard cold perfusion preservation in kidney transplantation (COMPARE): a randomised, double-blind, paired, phase 3 trial.
    Jochmans I; Brat A; Davies L; Hofker HS; van de Leemkolk FEM; Leuvenink HGD; Knight SR; Pirenne J; Ploeg RJ;
    Lancet; 2020 Nov; 396(10263):1653-1662. PubMed ID: 33220737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. PO
    Pravisani R; Baccarani U; Molinari E; Cherchi V; Bacchetti S; Terrosu G; Avital I; Ekser B; Adani GL
    Int J Artif Organs; 2022 Aug; 45(8):666-671. PubMed ID: 35751368
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The role of flavin mononucleotide (FMN) as a potentially clinically relevant biomarker to predict the quality of kidney grafts during hypothermic (oxygenated) machine perfusion.
    van de Leemkolk FEM; Lo Faro ML; Shaheed S; Mulvey JF; Huurman VAL; Alwayn IPJ; Putter H; Jochmans I; Lindeman JHN; Ploeg RJ;
    PLoS One; 2023; 18(6):e0287713. PubMed ID: 37352336
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The Effects of Oxygenation on Ex Vivo Kidneys Undergoing Hypothermic Machine Perfusion.
    Patel K; Smith TB; Neil DAH; Thakker A; Tsuchiya Y; Higgs EB; Hodges NJ; Ready AR; Nath J; Ludwig C
    Transplantation; 2019 Feb; 103(2):314-322. PubMed ID: 30461718
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Oxygen Consumption by Warm Ischemia-Injured Porcine Kidneys in Hypothermic Static and Machine Preservation.
    Kaminski J; Delpech PO; Kaaki-Hosni S; Promeyrat X; Hauet T; Hannaert P
    J Surg Res; 2019 Oct; 242():78-86. PubMed ID: 31071608
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Mitochondrial respiratory chain and Krebs cycle enzyme function in human donor livers subjected to end-ischaemic hypothermic machine perfusion.
    Abudhaise H; Taanman JW; DeMuylder P; Fuller B; Davidson BR
    PLoS One; 2021; 16(10):e0257783. PubMed ID: 34710117
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of Oxygen During Long-term Hypothermic Machine Perfusion in a Porcine Model of Kidney Donation After Circulatory Death.
    Venema LH; Brat A; Moers C; 't Hart NA; Ploeg RJ; Hannaert P; Minor T; Leuvenink AHGD;
    Transplantation; 2019 Oct; 103(10):2057-2064. PubMed ID: 30951018
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Attempt to rescue discarded human liver grafts by end ischemic hypothermic oxygenated machine perfusion.
    Vekemans K; van Pelt J; Komuta M; Wylin T; Heedfeld V; Detry O; Monbaliu D; Pirenne J
    Transplant Proc; 2011 Nov; 43(9):3455-9. PubMed ID: 22099819
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of normothermic and hypothermic perfusion in porcine kidneys donated after cardiac death.
    Blum MF; Liu Q; Soliman B; Dreher P; Okamoto T; Poggio ED; Goldfarb DA; Baldwin WM; Quintini C
    J Surg Res; 2017 Aug; 216():35-45. PubMed ID: 28807212
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Role of oxygenation in hypothermic machine perfusion of kidneys from heart beating donors.
    Gallinat A; Paul A; Efferz P; Lüer B; Swoboda S; Hoyer D; Minor T
    Transplantation; 2012 Oct; 94(8):809-13. PubMed ID: 22992766
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Discriminate liver warm ischemic injury during hypothermic machine perfusion by proton magnetic resonance spectroscopy: a study in a porcine model.
    Liu Q; Vekemans K; van Pelt J; Pirenne J; Himmelreich U; Heedfeld V; Wylin T; Brassil J; Monbaliu D; Dresselaers T
    Transplant Proc; 2009 Oct; 41(8):3383-6. PubMed ID: 19857754
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved kidney graft function after preservation using a novel hypothermic machine perfusion device.
    Maathuis MH; Manekeller S; van der Plaats A; Leuvenink HG; 't Hart NA; Lier AB; Rakhorst G; Ploeg RJ; Minor T
    Ann Surg; 2007 Dec; 246(6):982-8; discussion 989-91. PubMed ID: 18043100
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An ex vivo comparison of adenosine and lidocaine solution and University of Wisconsin solution for hypothermic machine perfusion of porcine kidneys: potential for development.
    Hamaoui K; Aftab A; Gowers S; Boutelle M; Cook T; Rudd D; Dobson GP; Papalois V
    J Surg Res; 2017 Feb; 208():219-229. PubMed ID: 27993213
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.