These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 32766521)

  • 41. The impact of minimally invasive root canal preparation strategies on the ability to shape root canals of mandibular molars.
    Lima CO; Barbosa AFA; Ferreira CM; Augusto CM; Sassone LM; Lopes RT; Fidel SR; Silva EJNL
    Int Endod J; 2020 Dec; 53(12):1680-1688. PubMed ID: 32767779
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Evaluation of Canal-centering Ability and Apical Transportation of Hyflex-EDM, OneShape, WaveOne Gold, and Reciproc Files: An
    Subramanian A; Balasubramanian R; Jayakumar S; Harikrishnan S; Chandrasekaran R
    J Contemp Dent Pract; 2023 Oct; 24(10):802-808. PubMed ID: 38152914
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Accumulated Hard Tissue Debris and Root Canal Shaping Profiles Following Instrumentation with Gentlefile, One Curve, and Reciproc Blue.
    Chan CW; Romeo VR; Lee A; Zhang C; Neelakantan P; Pedullà E
    J Endod; 2023 Oct; 49(10):1344-1351. PubMed ID: 37516238
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Comparative Evaluation of Root Canal Centering Ability of ProTaper, Mtwo, WaveOne, and Reciproc Using Cone-beam Computed Tomography:
    Remya M; Singh P; Varughese A; Joseph A; Chandran P; Subramanian D; Kumar SV
    J Contemp Dent Pract; 2022 Sep; 23(6):589-592. PubMed ID: 36259296
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Micro-computed Tomographic Assessment of the Residual Filling Volume, Apical Transportation, and Crack Formation after Retreatment with Reciproc and Reciproc Blue Systems in Curved Root Canals.
    Kırıcı D; Demirbuga S; Karataş E
    J Endod; 2020 Feb; 46(2):238-243. PubMed ID: 31883621
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Apical transportation using Mtwo or Reciproc retreatment systems in severely curved canals: a micro-computed tomographic study.
    Gomes ILL; Alves FRF; Marceliano-Alves MF; Silveira SB; Sousa JCN; Provenzano JC; Gonçalves LS
    Clin Oral Investig; 2023 Mar; 27(3):1235-1241. PubMed ID: 36264344
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Shaping ability of BioRace, ProTaper NEXT and Genius nickel-titanium instruments in curved canals of mandibular molars: a MicroCT study.
    Drukteinis S; Peciuliene V; Dummer PMH; Hupp J
    Int Endod J; 2019 Jan; 52(1):86-93. PubMed ID: 29858500
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Micro-computed Evaluation of Canal Transportation and Centering Ability of 5 Rotary and Reciprocating Systems with Different Metallurgical Properties and Surface Treatments in Curved Root Canals.
    Kabil E; Katić M; Anić I; Bago I
    J Endod; 2021 Mar; 47(3):477-484. PubMed ID: 33217469
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Influence of cervical preflaring on apical transportation in curved root canals instrumented by reciprocating file systems.
    Barbieri N; Leonardi DP; Baechtold MS; Correr GM; Gabardo MC; Zielak JC; Baratto-Filho F
    BMC Oral Health; 2015 Nov; 15():149. PubMed ID: 26593244
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Glide Path Management with Single- and Multiple-instrument Rotary Systems in Curved Canals: A Micro-Computed Tomographic Study.
    Kirchhoff AL; Chu R; Mello I; Garzon AD; dos Santos M; Cunha RS
    J Endod; 2015 Nov; 41(11):1880-3. PubMed ID: 26395910
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Apical Transportation, Centering Ratio, and Volume Increase after Manual, Rotary, and Reciprocating Instrumentation in Curved Root Canals: Analysis by Micro-computed Tomographic and Digital Subtraction Radiography.
    Zanesco C; Só MV; Schmidt S; Fontanella VR; Grazziotin-Soares R; Barletta FB
    J Endod; 2017 Mar; 43(3):486-490. PubMed ID: 28231983
    [TBL] [Abstract][Full Text] [Related]  

  • 52. In Vitro Transportation of Curved Canals Following Glide Path Preparation by Path File and Scout RaCe Rotary Systems versus Manual Instrumentation Using Cone-Beam Computed Tomography.
    Aflaki S; Boyerahmadi E; Talaei A; Safari MR; Mohammadpour M; Mohammadi N; Adel M
    Front Dent; 2020; 17():30. PubMed ID: 36042800
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Comparative evaluation of the shaping ability of WaveOne, Reciproc and OneShape single-file systems in severely curved root canals of extracted teeth.
    Saber SE; Nagy MM; Schäfer E
    Int Endod J; 2015 Jan; 48(1):109-14. PubMed ID: 24673737
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Comparative analysis of canal transportation and centring ability of three Ni-Ti rotary endodontic systems: Protaper®, MTwo® and Revo-S™, assessed by micro-computed tomography.
    Vallaeys K; Chevalier V; Arbab-Chirani R
    Odontology; 2016 Jan; 104(1):83-8. PubMed ID: 25248755
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Comparison of root canal transportation induced by three rotary systems with noncutting tips using computed tomography.
    Özer SY
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2011 Feb; 111(2):244-50. PubMed ID: 21167759
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Efficacy of CM-Wire, M-Wire, and Nickel-Titanium Instruments for Removing Filling Material from Curved Root Canals: A Micro-Computed Tomography Study.
    Rodrigues CT; Duarte MA; de Almeida MM; de Andrade FB; Bernardineli N
    J Endod; 2016 Nov; 42(11):1651-1655. PubMed ID: 27651042
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Comparison of apical transportation and centering ability of Mtwo and Reciproc R25 in severely curved canals using cone-beam computed tomography.
    Mesgarani A; Hamidi MR; Haghanifar S; Naiemi S; Bijani A
    Dent Res J (Isfahan); 2018; 15(1):57-62. PubMed ID: 29497448
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Micro-Computed Tomography Study of Filling Material Removal from Oval-shaped Canals by Using Rotary, Reciprocating, and Adaptive Motion Systems.
    Crozeta BM; Silva-Sousa YT; Leoni GB; Mazzi-Chaves JF; Fantinato T; Baratto-Filho F; Sousa-Neto MD
    J Endod; 2016 May; 42(5):793-7. PubMed ID: 26987688
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Both operator and heat treatment determine the centring ability of Reciproc® files in vitro.
    Hofmann N
    Clin Oral Investig; 2019 Feb; 23(2):697-706. PubMed ID: 29752532
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Safety of large preparation with different instruments in the buccal canals of maxillary molars.
    de Camargo EJ; Duarte MAH; Alcalde MP; Só MVDR; Vasconcelos BC; Silva EJNL; Plotino G; Vivan RR
    Aust Endod J; 2021 Apr; 47(1):81-89. PubMed ID: 33368843
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.