These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 32766747)

  • 1. Short-Term Changes in the Photopic Negative Response Following Intraocular Pressure Lowering in Glaucoma.
    Tang J; Hui F; Hadoux X; Soares B; Jamieson M; van Wijngaarden P; Coote M; Crowston JG
    Invest Ophthalmol Vis Sci; 2020 Aug; 61(10):16. PubMed ID: 32766747
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intraocular pressure lowering is associated with an increase in the photopic negative response (PhNR) amplitude in glaucoma and ocular hypertensive eyes.
    Niyadurupola N; Luu CD; Nguyen DQ; Geddes K; Tan GX; Wong CC; Tran T; Coote MA; Crowston JG
    Invest Ophthalmol Vis Sci; 2013 Mar; 54(3):1913-9. PubMed ID: 23385794
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ganglion cell loss in early glaucoma, as assessed by photopic negative response, pattern electroretinogram, and spectral-domain optical coherence tomography.
    Cvenkel B; Sustar M; Perovšek D
    Doc Ophthalmol; 2017 Aug; 135(1):17-28. PubMed ID: 28567618
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between broadband and monochromatic photopic negative response in full-field electroretinogram in controls and subjects with primary open-angle glaucoma.
    Banerjee A; Khurana M; Sachidanandam R; Sen P
    Doc Ophthalmol; 2019 Feb; 138(1):21-33. PubMed ID: 30635745
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Relationship between Macular Vessel Density and Focal Electroretinograms in Early Normal Tension Glaucoma.
    Honda H; Anraku A; Ishida K; Enomoto N; Tomita G
    Curr Eye Res; 2019 Jul; 44(7):753-759. PubMed ID: 30869542
    [No Abstract]   [Full Text] [Related]  

  • 6. Regional variations in correlation between photopic negative response of focal electoretinograms and ganglion cell complex in glaucoma.
    Machida S; Kaneko M; Kurosaka D
    Curr Eye Res; 2015 Apr; 40(4):439-49. PubMed ID: 24871085
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intensity response function of the photopic negative response (PhNR): effect of age and test-retest reliability.
    Joshi NR; Ly E; Viswanathan S
    Doc Ophthalmol; 2017 Aug; 135(1):1-16. PubMed ID: 28508299
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Alterations of photopic negative response of multifocal electroretinogram in patients with glaucoma.
    Kaneko M; Machida S; Hoshi Y; Kurosaka D
    Curr Eye Res; 2015 Jan; 40(1):77-86. PubMed ID: 24832792
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Restoration of retinal ganglion cell function in early glaucoma after intraocular pressure reduction: a pilot study.
    Ventura LM; Porciatti V
    Ophthalmology; 2005 Jan; 112(1):20-7. PubMed ID: 15629815
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reversible structural and functional changes after intraocular pressure reduction in patients with glaucoma.
    Waisbourd M; Ahmed OM; Molineaux J; Gonzalez A; Spaeth GL; Katz LJ
    Graefes Arch Clin Exp Ophthalmol; 2016 Jun; 254(6):1159-66. PubMed ID: 26995555
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Functional Loss of the Inner Retina in Childhood Optic Gliomas Detected by Photopic Negative Response.
    Abed E; Piccardi M; Rizzo D; Chiaretti A; Ambrosio L; Petroni S; Parrilla R; Dickmann A; Riccardi R; Falsini B
    Invest Ophthalmol Vis Sci; 2015 Apr; 56(4):2469-74. PubMed ID: 25634980
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The photopic negative response of the macaque electroretinogram: reduction by experimental glaucoma.
    Viswanathan S; Frishman LJ; Robson JG; Harwerth RS; Smith EL
    Invest Ophthalmol Vis Sci; 1999 May; 40(6):1124-36. PubMed ID: 10235545
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparing three different modes of electroretinography in experimental glaucoma: diagnostic performance and correlation to structure.
    Wilsey L; Gowrisankaran S; Cull G; Hardin C; Burgoyne CF; Fortune B
    Doc Ophthalmol; 2017 Apr; 134(2):111-128. PubMed ID: 28243926
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Correlation between photopic negative response and retinal nerve fiber layer thickness and optic disc topography in glaucomatous eyes.
    Machida S; Gotoh Y; Toba Y; Ohtaki A; Kaneko M; Kurosaka D
    Invest Ophthalmol Vis Sci; 2008 May; 49(5):2201-7. PubMed ID: 18436853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Photopic negative response of full-field electroretinography in patients with different stages of glaucomatous optic neuropathy.
    Kirkiewicz M; Lubiński W; Penkala K
    Doc Ophthalmol; 2016 Feb; 132(1):57-65. PubMed ID: 26831670
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Significant correlations between photopic negative response, afferent pupillary defect, and mean defects of visual fields in asymmetric optic nerve disorders.
    Okuno T; Kida T; Ikeda T; Oku H
    Graefes Arch Clin Exp Ophthalmol; 2020 Aug; 258(8):1821-1827. PubMed ID: 32080769
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of Changes in Macular Ganglion Cell-Inner Plexiform Layer Thickness Between Medically and Surgically Treated Eyes With Advanced Glaucoma.
    Inuzuka H; Sawada A; Yamamoto T
    Am J Ophthalmol; 2018 Mar; 187():43-50. PubMed ID: 29288029
    [TBL] [Abstract][Full Text] [Related]  

  • 18. ISCEV extended protocol for the photopic negative response (PhNR) of the full-field electroretinogram.
    Frishman L; Sustar M; Kremers J; McAnany JJ; Sarossy M; Tzekov R; Viswanathan S
    Doc Ophthalmol; 2018 Jun; 136(3):207-211. PubMed ID: 29855761
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Retinal ganglion cell ablation in guinea pigs.
    Jnawali A; Lin X; Patel NB; Frishman LJ; Ostrin LA
    Exp Eye Res; 2021 Jan; 202():108339. PubMed ID: 33127343
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of lowering intraocular pressure on optical coherence tomography measurement of peripapillary retinal nerve fiber layer thickness.
    Chang PT; Sekhon N; Budenz DL; Feuer WJ; Park PW; Anderson DR
    Ophthalmology; 2007 Dec; 114(12):2252-8. PubMed ID: 17466378
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.