220 related articles for article (PubMed ID: 32767287)
1. Long-term placement of lumen-apposing metal stent after endoscopic ultrasound-guided duodeno- and jejunojejunal anastomosis for direct access to excluded jejunal limb.
Donatelli G; Cereatti F; Spota A; Danan D; Tuszynski T; Dumont JL; Derhy S
Endoscopy; 2021 Mar; 53(3):293-297. PubMed ID: 32767287
[TBL] [Abstract][Full Text] [Related]
2. Endoscopic gastrointestinal anastomoses with lumen-apposing metal stents: predictors of technical success.
Wannhoff A; Ruh N; Meier B; Riecken B; Caca K
Surg Endosc; 2021 May; 35(5):1997-2004. PubMed ID: 32358692
[TBL] [Abstract][Full Text] [Related]
3. Lumen-apposing metal stent placement after endoscopic ultrasound-guided duodenojejunal anastomosis for direct access to excluded jejunal limb: findings after 5 years.
D'Errico F; Derhy S; Donatelli G
Endoscopy; 2023 Dec; 55(S 01):E344-E345. PubMed ID: 36646119
[No Abstract] [Full Text] [Related]
4. Lumen-apposing metal stents for malignant biliary obstruction: Is this the ultimate horizon of our experience?
Anderloni A; Troncone E; Fugazza A; Cappello A; Del Vecchio Blanco G; Monteleone G; Repici A
World J Gastroenterol; 2019 Aug; 25(29):3857-3869. PubMed ID: 31413524
[TBL] [Abstract][Full Text] [Related]
5. Experimental study of a physician-controlled electrocautery-enhanced delivery system incorporating a newly developed lumen-apposing metal stent for interventional endoscopic ultrasound (with videos).
Mukai S; Itoi T; Tsuchiya T; Ishii K; Tanaka R; Tonozuka R; Furuichi Y; Joyama E; Miyazawa H; Sofuni A
J Hepatobiliary Pancreat Sci; 2022 Jul; 29(7):817-824. PubMed ID: 35030302
[TBL] [Abstract][Full Text] [Related]
6. EUS-guided Anastomosis Complication in a Patient with Roux-en-Y Gastric Bypass: Dehiscence of the Surgical Anastomosis During Endoscopic Mucosal Resection Across EUS-guided Jejunum-gastric Anastomosis with Lumen Apposing Metal Stent.
Donatelli G; Cereatti F; Daho F
Obes Surg; 2021 Jul; 31(7):3384-3385. PubMed ID: 33855693
[TBL] [Abstract][Full Text] [Related]
7. EUS-guided drainage of peripancreatic fluid collections and necrosis by using a novel lumen-apposing stent: a large retrospective, multicenter U.S. experience (with videos).
Siddiqui AA; Adler DG; Nieto J; Shah JN; Binmoeller KF; Kane S; Yan L; Laique SN; Kowalski T; Loren DE; Taylor LJ; Munigala S; Bhat YM
Gastrointest Endosc; 2016 Apr; 83(4):699-707. PubMed ID: 26515956
[TBL] [Abstract][Full Text] [Related]
8. EUS-Guided Choledochoduodenostomy for Distal Malignant Biliary Obstruction Using Electrocautery-Enhanced Lumen-Apposing Metal Stents: First US, Multicenter Experience.
El Chafic AH; Shah JN; Hamerski C; Binmoeller KF; Irani S; James TW; Baron TH; Nieto J; Romero RV; Evans JA; Kahaleh M
Dig Dis Sci; 2019 Nov; 64(11):3321-3327. PubMed ID: 31175495
[TBL] [Abstract][Full Text] [Related]
9. Comparison of the effectiveness and safety of lumen-apposing metal stents and anti-migrating tubular self-expandable metal stents for EUS-guided gallbladder drainage in high surgical risk patients with acute cholecystitis.
Cho SH; Oh D; Song TJ; Park DH; Seo DW; Lee SK; Kim MH; Lee YN; Moon JH; Lee SS
Gastrointest Endosc; 2020 Mar; 91(3):543-550. PubMed ID: 31629721
[TBL] [Abstract][Full Text] [Related]
10. Feasibility and patency of echoendoscopic anastomoses with lumen apposing metal stents depending on the gastrointestinal segment involved.
Betés M; Pérez-Longo P; Peralta S; Bojorquez A; Angós R; Chopitea A; Baixauli J; Munoz-Navas M; Súbtil JC
Sci Rep; 2021 Feb; 11(1):3992. PubMed ID: 33597612
[TBL] [Abstract][Full Text] [Related]
11. A novel electrocautery-enhanced delivery system for one-step endoscopic ultrasound-guided drainage of the gallbladder and bile duct using a lumen-apposing metal stent: a feasibility study.
Yoo HW; Moon JH; Jo SJ; Lee YN; Park JK; Lee TH; Cha SW; Cho YD; Park SH; Park SI; Jeong S; Lee DH
Endoscopy; 2021 Sep; 53(9):922-926. PubMed ID: 33336343
[TBL] [Abstract][Full Text] [Related]
12. Endoscopic Ultrasound Guided Choledocho-Enterostomy by Using Lumen Apposing Metal Stent in Patients with Failed Endoscopic Retrograde Cholangiopancreatography: A Literature Review.
Jain D; Shah M; Patel U; Sharma A; Singhal S
Digestion; 2018; 98(1):1-10. PubMed ID: 29672294
[TBL] [Abstract][Full Text] [Related]
13. Endoscopic ultrasound-guided drainage using lumen-apposing metal stent of malignant afferent limb syndrome in patients with previous Whipple surgery: Multicenter study (with video).
Pérez-Cuadrado-Robles E; Bronswijk M; Prat F; Barthet M; Palazzo M; Arcidiacono P; Schaefer M; Devière J; van Wanrooij RLJ; Tarantino I; Donatelli G; Camus M; Sanchez-Yague A; Pham KD; Gonzalez JM; Anderloni A; Vila JJ; Jezequel J; Larghi A; Jaïs B; Vazquez-Sequeiros E; Deprez PH; Van der Merwe S; Cellier C; Rahmi G
Dig Endosc; 2022 Nov; 34(7):1433-1439. PubMed ID: 35429360
[TBL] [Abstract][Full Text] [Related]
14. Lumen-apposing metals stents in advanced endoscopic ultrasound-guided interventions: novel applications, potential complications and radiologic assessment.
Li J; Basseri H; Donnellan F; Harris A
Abdom Radiol (NY); 2021 Feb; 46(2):776-791. PubMed ID: 32761403
[TBL] [Abstract][Full Text] [Related]
15. Clinical application and follow-up of electrocautery-enhanced lumen-apposing metal stents for endoscopic ultrasonography-guided interventions.
She YM; Ge N
Ann Med; 2023; 55(2):2282748. PubMed ID: 37967551
[No Abstract] [Full Text] [Related]
16. What is the ideal indwelling time for metal stents after endoscopic ultrasound-guided gastrojejunostomy? Case report of delayed iatrogenic perforation with a review of the literature.
Taibi A; Durand Fontanier S; Derbal S; Lepetit H; Christou N; Fredon F; Mathonnet M; Jacques J
Dig Endosc; 2020 Jul; 32(5):816-822. PubMed ID: 32022334
[TBL] [Abstract][Full Text] [Related]
17. Comparison of Clinical Outcomes between Plastic Stent and Novel Lumen-apposing Metal Stent for Endoscopic Ultrasound-Guided Drainage of Peripancreatic Fluid Collections.
Shin HC; Cho CM; Jung MK; Yeo SJ
Clin Endosc; 2019 Jul; 52(4):353-359. PubMed ID: 30862153
[TBL] [Abstract][Full Text] [Related]
18. Long-term outcomes of EUS-guided choledochoduodenostomy using a lumen-apposing metal stent for malignant distal biliary obstruction: a prospective multicenter study.
Tsuchiya T; Teoh AYB; Itoi T; Yamao K; Hara K; Nakai Y; Isayama H; Kitano M
Gastrointest Endosc; 2018 Apr; 87(4):1138-1146. PubMed ID: 28843583
[TBL] [Abstract][Full Text] [Related]
19. Safety issues in endoscopy ultrasound-guided interventions using lumen apposing metal stents.
Auriemma F; Fugazza A; Colombo M; Spadaccini M; Repici A; Anderloni A
Minerva Gastroenterol (Torino); 2022 Jun; 68(2):177-185. PubMed ID: 33871222
[TBL] [Abstract][Full Text] [Related]
20. Lumen-Apposing Metal Stents: Which One and Why?
Stier MW; Waxman I
Gastrointest Endosc Clin N Am; 2018 Apr; 28(2):207-217. PubMed ID: 29519333
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]