BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

771 related articles for article (PubMed ID: 32767288)

  • 1. Comparison of endoscopic ultrasound-guided fine-needle biopsy versus fine-needle aspiration for genomic profiling and DNA yield in pancreatic cancer: a randomized crossover trial.
    Kandel P; Nassar A; Gomez V; Raimondo M; Woodward TA; Crook JE; Fares NS; Wallace MB
    Endoscopy; 2021 Apr; 53(4):376-382. PubMed ID: 32767288
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Endoscopic ultrasound-guided sampling of solid pancreatic masses: 22-gauge aspiration versus 25-gauge biopsy needles.
    Yang MJ; Yim H; Hwang JC; Lee D; Kim YB; Lim SG; Kim SS; Kang JK; Yoo BM; Kim JH
    BMC Gastroenterol; 2015 Sep; 15():122. PubMed ID: 26419845
    [TBL] [Abstract][Full Text] [Related]  

  • 3. EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study.
    Kandel P; Tranesh G; Nassar A; Bingham R; Raimondo M; Woodward TA; Gomez V; Wallace MB
    Gastrointest Endosc; 2016 Dec; 84(6):1034-1039. PubMed ID: 27018087
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of 22-gauge standard fine needle versus core biopsy needle for endoscopic ultrasound-guided sampling of suspected pancreatic cancer: a randomized crossover trial.
    Noh DH; Choi K; Gu S; Cho J; Jang KT; Woo YS; Lee KT; Lee JK; Lee KH
    Scand J Gastroenterol; 2018 Jan; 53(1):94-99. PubMed ID: 29065734
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Touch imprint cytology on endoscopic ultrasound fine-needle biopsy provides comparable sample quality and diagnostic yield to standard endoscopic ultrasound fine-needle aspiration specimens in the evaluation of solid pancreatic lesions.
    Crinò SF; Larghi A; Bernardoni L; Parisi A; Frulloni L; Gabbrielli A; Parcesepe P; Scarpa A; Manfrin E
    Cytopathology; 2019 Mar; 30(2):179-186. PubMed ID: 30484917
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Adequacy evaluation and use of pancreatic adenocarcinoma specimens for next-generation sequencing acquired by endoscopic ultrasound-guided FNA and FNB.
    Gan Q; Roy-Chowdhuri S; Duose DY; Stewart JM; Coronel E; Bhutani MS; Lee JH; Weston B; Ge PS; Ross WA; Maitra A
    Cancer Cytopathol; 2022 Apr; 130(4):275-283. PubMed ID: 34905283
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study.
    Lee YN; Moon JH; Kim HK; Choi HJ; Choi MH; Kim DC; Lee TH; Cha SW; Cho YD; Park SH
    Endoscopy; 2014 Dec; 46(12):1056-62. PubMed ID: 25098611
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In memoriam: Fine-needle aspiration, birth: Fine-needle biopsy: The changing trend in endoscopic ultrasound-guided tissue acquisition.
    Bang JY; Kirtane S; Krall K; Navaneethan U; Hasan M; Hawes R; Varadarajulu S
    Dig Endosc; 2019 Mar; 31(2):197-202. PubMed ID: 30256458
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Analysis of Fine-Needle Biopsy vs Fine-Needle Aspiration in Diagnosis of Pancreatic and Abdominal Masses: A Prospective, Multicenter, Randomized Controlled Trial.
    Cheng B; Zhang Y; Chen Q; Sun B; Deng Z; Shan H; Dou L; Wang J; Li Y; Yang X; Jiang T; Xu G; Wang G
    Clin Gastroenterol Hepatol; 2018 Aug; 16(8):1314-1321. PubMed ID: 28733257
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Endoscopic Ultrasound-Guided Tissue Acquisition by 22-Gauge Franseen and Standard Needles for Solid Pancreatic Lesions.
    Ishigaki K; Nakai Y; Oyama H; Kanai S; Suzuki T; Nakamura T; Sato T; Hakuta R; Saito K; Saito T; Takahara N; Hamada T; Mizuno S; Kogure H; Tada M; Isayama H; Koike K
    Gut Liver; 2020 Nov; 14(6):817-825. PubMed ID: 32457276
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Endoscopic ultrasound with combined fine needle aspiration plus biopsy improves diagnostic yield in solid pancreatic masses.
    Gonzalez A; Wadhwa V; Singh H; Khan S; Gupta K; Liang H; Hussain I; Vargo J; Jang S; Chahal P; Bhatt A; Siddiki H; Erim T; Sanaka MR
    Scand J Gastroenterol; 2022 May; 57(5):610-617. PubMed ID: 34991430
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of tissue and molecular yield between fine-needle biopsy (FNB) and fine-needle aspiration (FNA): a randomized study.
    Asokkumar R; Yung Ka C; Loh T; Kah Ling L; Gek San T; Ying H; Tan D; Khor C; Lim T; Soetikno R
    Endosc Int Open; 2019 Aug; 7(8):E955-E963. PubMed ID: 31367675
    [No Abstract]   [Full Text] [Related]  

  • 13. Improved diagnostic yield of endoscopic ultrasound-fine needle biopsy with histology specimen processing.
    Ku L; Shahshahan MA; Hou LA; Eysselein VE; Reicher S
    World J Gastrointest Endosc; 2020 Aug; 12(8):212-219. PubMed ID: 32879656
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Meta-Analysis Comparing Endoscopic Ultrasound-guided Fine-needle Aspiration With Endoscopic Ultrasound-guided Fine-needle Biopsy.
    Li Z; Liu W; Xu X; Li P
    J Clin Gastroenterol; 2022 Sep; 56(8):668-678. PubMed ID: 35470294
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of 22G fine-needle aspiration (FNA) versus fine-needle biopsy (FNB) for endoscopic ultrasound-guided sampling of pancreatic lesions: a prospective comparison study.
    Tian L; Tang AL; Zhang L; Liu XW; Li JB; Wang F; Shen SR; Wang XY
    Surg Endosc; 2018 Aug; 32(8):3533-3539. PubMed ID: 29404729
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic performance of endoscopic ultrasound-guided tissue acquisition by EUS-FNA versus EUS-FNB for solid pancreatic mass without ROSE: a retrospective study.
    Wong T; Pattarapuntakul T; Netinatsunton N; Ovartlarnporn B; Sottisuporn J; Chamroonkul N; Sripongpun P; Jandee S; Kaewdech A; Attasaranya S; Piratvisuth T
    World J Surg Oncol; 2022 Jun; 20(1):215. PubMed ID: 35751053
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of FNA and fine-needle biopsy for EUS-guided sampling of suspected GI stromal tumors.
    El Chafic AH; Loren D; Siddiqui A; Mounzer R; Cosgrove N; Kowalski T
    Gastrointest Endosc; 2017 Sep; 86(3):510-515. PubMed ID: 28131864
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The yield of cytology and histology obtained by endoscopic ultrasound-guided fine needle aspiration and biopsy needles in the diagnosis of pancreatic adenocarcinoma.
    Sbeit W; Abu Hanna N; Alejandro L; Khoury T
    Cytopathology; 2024 Jan; 35(1):92-97. PubMed ID: 37698128
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A randomized controlled cross-over trial and cost analysis comparing endoscopic ultrasound fine needle aspiration and fine needle biopsy.
    Aadam AA; Wani S; Amick A; Shah JN; Bhat YM; Hamerski CM; Klapman JB; Muthusamy VR; Watson RR; Rademaker AW; Keswani RN; Keefer L; Das A; Komanduri S
    Endosc Int Open; 2016 May; 4(5):E497-505. PubMed ID: 27227104
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Endoscopic ultrasound (EUS)-guided fine needle biopsy alone vs. EUS-guided fine needle aspiration with rapid onsite evaluation in pancreatic lesions: a multicenter randomized trial.
    Chen YI; Chatterjee A; Berger R; Kanber Y; Wyse J; Lam E; Gan I; Auger M; Kenshil S; Telford J; Donnellan F; Quinlan J; Lutzak G; Alshamsi F; Parent J; Waschke K; Alghamdi A; Barkun J; Metrakos P; Chaudhury P; Martel M; Dorreen A; Candido K; Miller C; Adam V; Barkun A; Zogopoulos G; Wong C
    Endoscopy; 2022 Jan; 54(1):4-12. PubMed ID: 33506455
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 39.