These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 32769276)

  • 21. Retention of Different Attachment Systems for Digitally Designed Mandibular Implant Overdenture.
    Abdelaziz MS; Fawzy AM; Ghali RM; Nassar HI
    J Prosthodont; 2023 Feb; 32(2):162-169. PubMed ID: 35344237
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Effect of Implant Location on Palateless Complete Overdenture Retention: an
    El-Amier N; Elsaih E; Gibreel M; El-Motaiam H
    J Oral Maxillofac Res; 2018; 9(3):e3. PubMed ID: 30429963
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Resilient Stud Versus Bar Attachments for Inclined Implants Supporting Mandibular Overdentures. An In Vitro Study of Loading and Dislodging Strains.
    Elhelbawy NG; ELsyad MA; Soliman TA; Mahrous A
    Int J Oral Maxillofac Implants; 2022; 37(5):982-988. PubMed ID: 36170313
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Attachment systems for implant overdenture: influence of implant inclination on retentive and lateral forces.
    Yang TC; Maeda Y; Gonda T; Kotecha S
    Clin Oral Implants Res; 2011 Nov; 22(11):1315-9. PubMed ID: 21426402
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Finite Element Analysis of Stress Distribution in Mandibles with Different Bone Types Loaded by Implant-Supported Overdentures with Different Localizations of Locator Attachments.
    Yıldırım RS; Buyukerkmen EB
    Int J Oral Maxillofac Implants; 2021; 36(5):851-862. PubMed ID: 34698710
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Angled ball and locator attachments for immediate loaded inclined implants used to retain maxillary overdentures: A cross over study of patient satisfaction and oral health related quality of life.
    Aboelez MA; Elezz MGA; Abdraboh AE; Elsyad MA
    Clin Implant Dent Relat Res; 2022 Jun; 24(3):391-400. PubMed ID: 35503746
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect of implant diameter on strain around implants retaining a mandibular overdenture with Locator attachments: An in vitro study.
    Elsyad MA; Elhddad AA; Khirallah AS
    Dent Mater J; 2016; 35(6):938-945. PubMed ID: 27904088
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effect of Attachment Type on Denture Strain in Maxillary Implant Overdentures: Part 1. Overdenture with Palate.
    Takahashi T; Gonda T; Maeda Y
    Int J Oral Maxillofac Implants; 2017; 32(4):815-821. PubMed ID: 28708913
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Biomechanical behavior of mandibular overdenture retained by two standard implants or 2 mini implants: A 3-dimensional finite element analysis.
    Patil PG; Seow LL; Uddanwadikar R; Ukey PD
    J Prosthet Dent; 2021 Jan; 125(1):138.e1-138.e8. PubMed ID: 33393474
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Effect of Distal Implant Inclination on Dislodging Forces of Different Locator Attachments Used for Mandibular Overdentures: An In Vitro Study.
    ELsyad MA; Emera RM; Ashmawy TM
    J Prosthodont; 2019 Feb; 28(2):e666-e674. PubMed ID: 29143403
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Assessment of the changes in retention and surface topography of attachments for maxillary 4-implant-retained overdentures.
    Kuo HY; Kuo PJ; Bittner N; Cavallaro J
    J Prosthet Dent; 2021 Sep; 126(3):413.e1-413.e9. PubMed ID: 34127250
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Maxillary implant overdentures retained by use of bars or locator attachments: 1-year findings from a randomized controlled trial.
    Boven GC; Meijer HJA; Vissink A; Raghoebar GM
    J Prosthodont Res; 2020 Jan; 64(1):26-33. PubMed ID: 31201036
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Influence of Implant Distribution and Palatal Coverage on the Strain of Splinted Implant and Overdenture in Maxillary Implant Overdentures.
    Nishimura Y; Takahashi T; Gonda T; Ikebe K
    Int J Oral Maxillofac Implants; 2021; 36(2):281-288. PubMed ID: 33909717
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments - an in vitro study.
    Srinivasan M; Schimmel M; Badoud I; Ammann P; Herrmann FR; Müller F
    Clin Oral Implants Res; 2016 May; 27(5):604-11. PubMed ID: 26085188
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Stress analysis of mandibular two-implant overdenture with different attachment systems.
    Takeshita S; Kanazawa M; Minakuchi S
    Dent Mater J; 2011; 30(6):928-34. PubMed ID: 22123019
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Retention and Stability of Implant-Retained Mandibular Overdentures Using Different Types of Resilient Attachments: An In Vitro Study.
    ELsyad MA; Agha NN; Habib AA
    Int J Oral Maxillofac Implants; 2016; 31(5):1040-8. PubMed ID: 27632258
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effects of Excessive Implant Angulation on Retention of Two Types of Overdenture Attachments during Cyclic Loading.
    Teimoori H; Shayegh SS; Zavaree MA; Hakimaneh SM; Khodadad F; Shidfar S; Baghani MT
    J Contemp Dent Pract; 2018 Oct; 19(10):1221-1227. PubMed ID: 30498177
    [TBL] [Abstract][Full Text] [Related]  

  • 38. An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.
    Fatalla AA; Song K; Du T; Cao Y
    J Huazhong Univ Sci Technolog Med Sci; 2012 Feb; 32(1):124-129. PubMed ID: 22282258
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Dislodgement force analysis of an overdenture attachment system.
    Yilmaz B; Ozkir E; Johnston WM; McGlumphy E
    J Prosthet Dent; 2020 Feb; 123(2):291-298. PubMed ID: 31202554
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Peri-implant strain around mesially inclined two-implant-retained mandibular overdentures with Locator attachments.
    Elsyad MA; Eltowery SM; Gebreel AA
    J Oral Sci; 2017 Dec; 59(4):483-490. PubMed ID: 29093282
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.