These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 32773401)

  • 1. Comparison of central, peripheral, and weighted size-specific dose in CT.
    Anam C; Adhianto D; Sutanto H; Adi K; Ali MH; Rae WID; Fujibuchi T; Dougherty G
    J Xray Sci Technol; 2020; 28(4):695-708. PubMed ID: 32773401
    [TBL] [Abstract][Full Text] [Related]  

  • 2. CT dose equilibration and energy absorption in polyethylene cylinders with diameters from 6 to 55 cm.
    Li X; Zhang D; Liu B
    Med Phys; 2015 Jun; 42(6):2882-91. PubMed ID: 26127041
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The impact of x-ray tube stabilization on localized radiation dose in axial CT scans: initial results in CTDI phantoms.
    Mathieu KB; McNitt-Gray MF; Cody DD
    Phys Med Biol; 2016 Oct; 61(20):7363-7376. PubMed ID: 27694696
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The importance of spectral separation: an assessment of dual-energy spectral separation for quantitative ability and dose efficiency.
    Krauss B; Grant KL; Schmidt BT; Flohr TG
    Invest Radiol; 2015 Feb; 50(2):114-8. PubMed ID: 25373305
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of tube voltage on CT noise levels in different phantom sizes.
    Karmazyn B; Liang Y; Klahr P; Jennings SG
    AJR Am J Roentgenol; 2013 May; 200(5):1001-5. PubMed ID: 23617481
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Radiation dose dependence on subject size in abdominal computed tomography: Water phantom and patient model comparison.
    Li X; Yang K; Liu B
    Med Phys; 2018 May; 45(5):2309-2317. PubMed ID: 29582439
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characterization of radiation dose from tube current modulated CT examinations with considerations of both patient size and variable tube current.
    Li X; Yang K; Liu B
    Med Phys; 2017 Oct; 44(10):5413-5422. PubMed ID: 28681439
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo assessment of CT dose equilibration in PMMA and water cylinders with diameters from 6 to 55 cm.
    Li X; Zhang D; Liu B
    Med Phys; 2013 Mar; 40(3):031903. PubMed ID: 23464318
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A study of the short- to long-phantom dose ratios for CT scanning without table translation.
    Li X; Zhang D; Yang J; Liu B
    Med Phys; 2014 Sep; 41(9):091912. PubMed ID: 25186399
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Identification of the computed tomography dose index for tube voltage variations in a polyester-resin phantom.
    Fatichah LN; Anam C; Sutanto H; Naufal A; Rukmana DA; Dougherty G
    Appl Radiat Isot; 2023 Feb; 192():110605. PubMed ID: 36502735
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A new method for CT dose estimation by determining patient water equivalent diameter from localizer radiographs: Geometric transformation and calibration methods using readily available phantoms.
    Zhang D; Mihai G; Barbaras LG; Brook OR; Palmer MR
    Med Phys; 2018 Jul; 45(7):3371-3378. PubMed ID: 29746705
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of the weighted CT dose index in modern multi-detector CT scanners.
    Perisinakis K; Damilakis J; Tzedakis A; Papadakis A; Theocharopoulos N; Gourtsoyiannis N
    Phys Med Biol; 2007 Nov; 52(21):6485-95. PubMed ID: 17951857
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluating Size-Specific Dose Estimate (SSDE) as an estimate of organ doses from routine CT exams derived from Monte Carlo simulations.
    Hardy AJ; Bostani M; Kim GHJ; Cagnon CH; Zankl MA; McNitt-Gray M
    Med Phys; 2021 Oct; 48(10):6160-6173. PubMed ID: 34309040
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Characteristics and clinical application of a treatment simulator with Ct-option.
    Verellen D; Vinh-Hung V; Bijdekerke P; Nijs F; Linthout N; Bel A; Storme G
    Radiother Oncol; 1999 Mar; 50(3):355-66. PubMed ID: 10392823
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Feasibility of size-specific organ-dose estimates based on water equivalent diameter for common head CT examinations: a Monte Carlo study.
    Tahiri M; Benameur Y; Mkimel M; El Baydaoui R; Mesardi MR
    J Radiol Prot; 2023 Apr; 43(2):. PubMed ID: 37056156
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A study of the midpoint dose to CTDI
    Li X; Yang K; Liu B
    Med Phys; 2016 Nov; 43(11):5878. PubMed ID: 27806599
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape.
    Siegel MJ; Schmidt B; Bradley D; Suess C; Hildebolt C
    Radiology; 2004 Nov; 233(2):515-22. PubMed ID: 15358847
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Calculation of water equivalent diameter based on anteroposterior localizer CT images].
    Liang B; Fu Y; Cao M
    Nan Fang Yi Ke Da Xue Xue Bao; 2020 Jun; 40(6):799-805. PubMed ID: 32895192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Estimation of size-specific dose estimates (SSDE) for paediatric and adults patients based on a single slice.
    Abuhaimed A; Martin CJ
    Phys Med; 2020 Jun; 74():30-39. PubMed ID: 32403067
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study.
    Thor D; Brismar TB; Fischer MA
    Med Phys; 2015 Sep; 42(9):5100-9. PubMed ID: 26328961
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.