These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
160 related articles for article (PubMed ID: 32773757)
1. Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm. Grootjans W; Kok P; Butter J; Aarntzen E J Vis Exp; 2020 Jul; (161):. PubMed ID: 32773757 [TBL] [Abstract][Full Text] [Related]
2. Amplitude-based optimal respiratory gating in positron emission tomography in patients with primary lung cancer. Grootjans W; de Geus-Oei LF; Meeuwis AP; van der Vos CS; Gotthardt M; Oyen WJ; Visser EP Eur Radiol; 2014 Dec; 24(12):3242-50. PubMed ID: 25097133 [TBL] [Abstract][Full Text] [Related]
3. Added Value of Respiratory Gating in Positron Emission Tomography for the Clinical Management of Lung Cancer Patients. Grootjans W; Rietbergen DDD; van Velden FHP Semin Nucl Med; 2022 Nov; 52(6):745-758. PubMed ID: 35643531 [TBL] [Abstract][Full Text] [Related]
4. The Impact of Optimal Respiratory Gating and Image Noise on Evaluation of Intratumor Heterogeneity on 18F-FDG PET Imaging of Lung Cancer. Grootjans W; Tixier F; van der Vos CS; Vriens D; Le Rest CC; Bussink J; Oyen WJ; de Geus-Oei LF; Visvikis D; Visser EP J Nucl Med; 2016 Nov; 57(11):1692-1698. PubMed ID: 27283931 [TBL] [Abstract][Full Text] [Related]
5. A data-driven respiratory motion estimation approach for PET based on time-of-flight weighted positron emission particle tracking. Tumpa TR; Acuff SN; Gregor J; Lee S; Hu D; Osborne DR Med Phys; 2021 Mar; 48(3):1131-1143. PubMed ID: 33226647 [TBL] [Abstract][Full Text] [Related]
6. Motion correction strategies for integrated PET/MR. Fürst S; Grimm R; Hong I; Souvatzoglou M; Casey ME; Schwaiger M; Nekolla SG; Ziegler SI J Nucl Med; 2015 Feb; 56(2):261-9. PubMed ID: 25572092 [TBL] [Abstract][Full Text] [Related]
7. Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. Boucher L; Rodrigue S; Lecomte R; Bénard F J Nucl Med; 2004 Feb; 45(2):214-9. PubMed ID: 14960638 [TBL] [Abstract][Full Text] [Related]
8. Four-dimensional (4D) PET/CT imaging of the thorax. Nehmeh SA; Erdi YE; Pan T; Pevsner A; Rosenzweig KE; Yorke E; Mageras GS; Schoder H; Vernon P; Squire O; Mostafavi H; Larson SM; Humm JL Med Phys; 2004 Dec; 31(12):3179-86. PubMed ID: 15651600 [TBL] [Abstract][Full Text] [Related]
10. Practical PET Respiratory Motion Correction in Clinical PET/MR. Manber R; Thielemans K; Hutton BF; Barnes A; Ourselin S; Arridge S; O'Meara C; Wan S; Atkinson D J Nucl Med; 2015 Jun; 56(6):890-6. PubMed ID: 25952740 [TBL] [Abstract][Full Text] [Related]
11. Impact of a new respiratory amplitude-based gating technique in evaluation of upper abdominal PET lesions. Van Der Gucht A; Serrano B; Hugonnet F; Paulmier B; Garnier N; Faraggi M Eur J Radiol; 2014 Mar; 83(3):509-15. PubMed ID: 24332351 [TBL] [Abstract][Full Text] [Related]
12. Evaluation of Data-Driven Respiration Gating in Continuous Bed Motion in Lung Lesions. Nii T; Hosokawa S; Kotani T; Domoto H; Nakamura Y; Tanada Y; Kondo R; Takahashi Y J Nucl Med Technol; 2023 Mar; 51(1):32-37. PubMed ID: 36750380 [TBL] [Abstract][Full Text] [Related]
13. Comparison of a free-breathing CT and an expiratory breath-hold CT with regard to spatial alignment of amplitude-based respiratory-gated PET and CT images. van der Vos CS; Grootjans W; Meeuwis AP; Slump CH; Oyen WJ; de Geus-Oei LF; Visser EP J Nucl Med Technol; 2014 Dec; 42(4):269-73. PubMed ID: 25342183 [TBL] [Abstract][Full Text] [Related]
14. External radioactive markers for PET data-driven respiratory gating in positron emission tomography. Büther F; Ernst I; Hamill J; Eich HT; Schober O; Schäfers M; Schäfers KP Eur J Nucl Med Mol Imaging; 2013 Apr; 40(4):602-14. PubMed ID: 23238525 [TBL] [Abstract][Full Text] [Related]
15. Improving the Spatial Alignment in PET/CT Using Amplitude-Based Respiration-Gated PET and Respiration-Triggered CT. van der Vos CS; Grootjans W; Osborne DR; Meeuwis AP; Hamill JJ; Acuff S; de Geus-Oei LF; Visser EP J Nucl Med; 2015 Dec; 56(12):1817-22. PubMed ID: 26383151 [TBL] [Abstract][Full Text] [Related]
16. A novel respiratory gating method for oncologic positron emission tomography based on bioimpedance approach. Koivumäki T; Teuho J; Teräs M; Vauhkonen M; Hakulinen MA Ann Nucl Med; 2015 May; 29(4):351-8. PubMed ID: 25638030 [TBL] [Abstract][Full Text] [Related]
17. Ultra-low dose CT attenuation correction for PET/CT: analysis of sparse view data acquisition and reconstruction algorithms. Rui X; Cheng L; Long Y; Fu L; Alessio AM; Asma E; Kinahan PE; De Man B Phys Med Biol; 2015 Oct; 60(19):7437-60. PubMed ID: 26352168 [TBL] [Abstract][Full Text] [Related]
18. Clinical comparison of the positron emission tracking (PeTrack) algorithm with the real-time position management system for respiratory gating in cardiac positron emission tomography. Manwell S; Klein R; Xu T; deKemp RA Med Phys; 2020 Apr; 47(4):1713-1726. PubMed ID: 31990986 [TBL] [Abstract][Full Text] [Related]
19. Frequency based gating: An alternative, conformal, approach to 4D PET data utilization. Kesner AL; Chung JH; Lind KE; Kwak JJ; Lynch D; Burckhardt D; Koo PJ Med Phys; 2016 Mar; 43(3):1451-61. PubMed ID: 26936729 [TBL] [Abstract][Full Text] [Related]