These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

205 related articles for article (PubMed ID: 32775200)

  • 1. Higher stability and more predictive fixation with the Femoral Neck System versus Hansson Pins in femoral neck fractures Pauwels II.
    Schopper C; Zderic I; Menze J; Müller D; Rocci M; Knobe M; Shoda E; Richards G; Gueorguiev B; Stoffel K
    J Orthop Translat; 2020 Sep; 24():88-95. PubMed ID: 32775200
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws.
    Stoffel K; Zderic I; Gras F; Sommer C; Eberli U; Mueller D; Oswald M; Gueorguiev B
    J Orthop Trauma; 2017 Mar; 31(3):131-137. PubMed ID: 27755333
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical comparison of femoral neck anti-rotation and support system versus femoral neck system for unstable pauwels III femoral neck fractures.
    Wang T; Wang G; Zhu F; Qiao B
    J Orthop Surg Res; 2024 Aug; 19(1):500. PubMed ID: 39175021
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical Comparison of Intramedullary Versus Extramedullary Implants for Fixation of Simple Pertrochanteric Fractures.
    Schader JF; Zderic I; Dauwe J; Sommer C; Gueorguiev B; Stoffel K
    J Orthop Trauma; 2023 May; 37(5):243-248. PubMed ID: 36728969
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture.
    Wang Z; Yang Y; Feng G; Guo H; Chen Z; Chen Y; Jin Q
    Biomed Eng Online; 2022 Jun; 21(1):34. PubMed ID: 35689282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation.
    Knobe M; Altgassen S; Maier KJ; Gradl-Dietsch G; Kaczmarek C; Nebelung S; Klos K; Kim BS; Gueorguiev B; Horst K; Buecking B
    Int Orthop; 2018 Feb; 42(2):409-418. PubMed ID: 28780597
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interlocked Pins Increase Strength by a Lateral Spread of Load in Femoral Neck Fixation: a Cadaver Study.
    Brattgjerd JE; Niratisairak S; Steen H; Strømsøe K
    Acta Chir Orthop Traumatol Cech; 2021; 88(2):144-152. PubMed ID: 33960928
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mechanical effects of sagittal variations on Pauwels type III femoral neck fractures treated with Femoral Neck System(FNS).
    Nan C; Ma L; Liang Y; Li Y; Ma Z
    BMC Musculoskelet Disord; 2022 Dec; 23(1):1045. PubMed ID: 36457095
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical study of femoral neck system for young patients with nonanatomically reduced femoral neck fractures: a finite element.
    Fan Z; Chen P; Yu X; Li X; Su H; Chen H; Yang B; Qi J; Wang H
    BMC Musculoskelet Disord; 2023 Jan; 24(1):54. PubMed ID: 36681804
    [TBL] [Abstract][Full Text] [Related]  

  • 10. What makes vertical femoral neck fracture with posterior inferior comminution different? An analysis of biomechanical features and optimal internal fixation strategy.
    Jiang D; Zhan S; Hai H; Wang L; Zhao J; Zhu Z; Wang T; Jia W
    Injury; 2023 Aug; 54(8):110842. PubMed ID: 37296009
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pinloc or Hansson pins: a multicenter, randomized controlled study of 439 patients treated for femoral neck fractures.
    Åberg H; Kalland K; Jonsson KB; Johansson T
    OTA Int; 2023 Dec; 6(4):e282. PubMed ID: 37744995
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fracture : a finite element analysis.
    Jung CH; Cha Y; Yoon HS; Park CH; Yoo JI; Kim JT; Jeon Y
    Bone Joint Res; 2022 Feb; 11(2):102-111. PubMed ID: 35168366
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intermediate Dynamic Compression and Decreased Posterior Tilt With Interlocked Pins in Femoral Neck Fixation in Synthetic Bone.
    Brattgjerd JE; Niratisairak S; Steen H; Strømsøe K
    J Biomech Eng; 2021 Jul; 143(7):. PubMed ID: 33625486
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Case ReportSubtrochanteric Fracture after Internal Fixation of Femoral Neck Fracture Using the Hansson Pinloc System: A Case Report.
    Yamada A; Yasui T; Miki Y; Nakamura S
    J Orthop Case Rep; 2022 Dec; 12(12):86-89. PubMed ID: 37056596
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Is bone-cement augmentation of screw-anchor fixation systems superior in unstable femoral neck fractures? A biomechanical cadaveric study.
    Knobe M; Bettag S; Kammerlander C; Altgassen S; Maier KJ; Nebelung S; Prescher A; Horst K; Pishnamaz M; Herren C; Mundt M; Stoffel M; Markert B; Gueorguiev B
    Injury; 2019 Feb; 50(2):292-300. PubMed ID: 30473370
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Standardized artificially created stable pertrochanteric femur fractures present more homogenous results compared to osteotomies for orthopaedic implant testing.
    Schader JF; Zderic I; Gehweiler D; Dauwe J; Mys K; Danker C; Acklin YP; Sommer C; Gueorguiev B; Stoffel K
    BMC Musculoskelet Disord; 2021 Apr; 22(1):371. PubMed ID: 33879133
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Survivability of the Femoral Neck System for the treatment of femoral neck fractures in adults.
    Stegelmann SD; Butler JT; Mathews DJ; Ostlie HC; Boothby BC; Phillips SA
    Eur J Orthop Surg Traumatol; 2023 Aug; 33(6):2555-2563. PubMed ID: 36645494
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical analysis of the femoral neck dynamic intersection system with different nail angles and clinical applications.
    Wang Y; Ma JX; Bai HH; Lu B; Sun L; Jin HZ; Ma XL
    World J Clin Cases; 2023 Jul; 11(20):4814-4823. PubMed ID: 37584003
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Increased stability by a novel femoral neck interlocking plate compared to conventional fixation methods. A biomechanical study in synthetic bone.
    Brattgjerd JE; Steen H; Strømsøe K
    Clin Biomech (Bristol, Avon); 2020 Jun; 76():104995. PubMed ID: 32416403
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increased torsional stability by a novel femoral neck locking plate. The role of plate design and pin configuration in a synthetic bone block model.
    Brattgjerd JE; Loferer M; Niratisairak S; Steen H; Strømsøe K
    Clin Biomech (Bristol, Avon); 2018 Jun; 55():28-35. PubMed ID: 29653317
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.