These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 32777989)

  • 1. Regional oxygen saturation change rate for detection of leg ischemia in minimally invasive cardiac surgery.
    Shikata F; Nakamura Y; Okuzono Y; Uchigasaki Y; Yamauchi N
    Perfusion; 2021 May; 36(4):382-387. PubMed ID: 32777989
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Risk factors to predict leg ischemia in patients undergoing single femoral artery cannulation in minimally invasive cardiac surgery.
    Tarui T; Miyata K; Shigematsu S; Watanabe G
    Perfusion; 2018 Oct; 33(7):533-537. PubMed ID: 29637839
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Efficacy of regional saturation of oxygen monitor using near-infrared spectroscopy for lower limb ischemia during minimally invasive cardiac surgery.
    Toya T; Fujita T; Fukushima S; Shimahara Y; Kume Y; Yamashita K; Matsumoto Y; Kawamoto N; Kobayashi J
    J Artif Organs; 2018 Dec; 21(4):420-426. PubMed ID: 29938392
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Incidence, predictors and vascular sequelae of distal limb ischemia in minimally invasive cardiac surgery with femoral artery cannulation: an observational cohort study.
    Ceulemans A; Derwael R; Vandenbrande J; Buyck K; Gruyters I; Van Tornout M; Murkin JM; Starinieri P; Yilmaz A; Stessel B
    Heart Vessels; 2023 Jul; 38(7):964-974. PubMed ID: 36723766
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Phase 1 Study of a Novel Bidirectional Perfusion Cannula in Patients Undergoing Femoral Cannulation for Cardiac Surgery.
    Marasco SF; Tutungi E; Vallance SA; Udy AA; Negri JC; Zimmet AD; McGiffin DC; Pellegrino VA; Moshinsky RA
    Innovations (Phila); 2018; 13(2):97-103. PubMed ID: 29697598
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Distal leg protection for peripheral cannulation in minimally invasive and totally endoscopic cardiac surgery.
    Bonaros N; Wiedemann D; Nagiller J; Feuchtner G; Kolbitsch C; Kaufmann M; Bonatti J; Schachner T
    Heart Surg Forum; 2009 Jun; 12(3):E158-62. PubMed ID: 19546069
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A noninvasive estimation of mixed venous oxygen saturation using near-infrared spectroscopy by cerebral oximetry in pediatric cardiac surgery patients.
    Tortoriello TA; Stayer SA; Mott AR; McKenzie ED; Fraser CD; Andropoulos DB; Chang AC
    Paediatr Anaesth; 2005 Jun; 15(6):495-503. PubMed ID: 15910351
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparative clinical efficacy of novel bidirectional cannula in cardiac surgery via peripheral cannulation for cardiopulmonary bypass.
    Gunaydin S; Babaroglu S; Budak AB; Sayin B; Cayhan V; Ozisik K
    Perfusion; 2023 Jan; 38(1):44-50. PubMed ID: 34304615
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Role of Regional Oxygen Saturation Using Near-Infrared Spectroscopy and Blood Lactate Levels as Early Predictors of Outcome After Pediatric Cardiac Surgery.
    Vida VL; Tessari C; Cristante A; Nori R; Pittarello D; Ori C; Cogo PE; Perissinotto E; Stellin G
    Can J Cardiol; 2016 Aug; 32(8):970-7. PubMed ID: 26868838
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Near infrared spectroscopy for controlling the quality of distal leg perfusion in remote access cardiopulmonary bypass.
    Schachner T; Bonaros N; Bonatti J; Kolbitsch C
    Eur J Cardiothorac Surg; 2008 Dec; 34(6):1253-4. PubMed ID: 18835786
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Utility of Ultrasonographic Assessment of Distal Femoral Arterial Flow during Minimally Invasive Valve Surgery.
    Hosono M; Yasumoto H; Kuwauchi S; Mitsunaga Y; Kanemoto S; Minato N; Kawazoe K
    Ann Thorac Cardiovasc Surg; 2021 Dec; 27(6):389-394. PubMed ID: 34092724
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Significant neonatal intraoperative cerebral and renal oxygen desaturation identified with near-infrared spectroscopy.
    Miyake Y; Seo S; Kataoka K; Ochi T; Miyano G; Koga H; Lane GJ; Nishimura K; Inada E; Yamataka A
    Pediatr Surg Int; 2022 May; 38(5):737-742. PubMed ID: 35246727
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Regional and central venous oxygen saturation monitoring following pediatric cardiac surgery: concordance and association with clinical variables.
    McQuillen PS; Nishimoto MS; Bottrell CL; Fineman LD; Hamrick SE; Glidden DV; Azakie A; Adatia I; Miller SP
    Pediatr Crit Care Med; 2007 Mar; 8(2):154-60. PubMed ID: 17273125
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Effects of Limb Elevation on Muscle Oxygen Saturation: A Near-Infrared Spectroscopy Study in Humans.
    Palanca AA; Yang A; Bishop JA
    PM R; 2016 Mar; 8(3):221-4. PubMed ID: 26261022
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An additional monitoring of regional cerebral oxygen saturation to HMPAO SPECT study during balloon test occlusion.
    Kaminogo M; Ochi M; Onizuka M; Takahata H; Shibata S
    Stroke; 1999 Feb; 30(2):407-13. PubMed ID: 9933280
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of optimising cerebral tissue oxygen saturation on markers of neurological injury during coronary artery bypass graft surgery.
    Harilall Y; Adam JK; Biccard BM; Reddi A
    Heart Lung Circ; 2014 Jan; 23(1):68-74. PubMed ID: 23911209
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Detection of lower torso ischemia by near-infrared spectroscopy during cardiopulmonary bypass in a 6.8-kg infant with complex aortic anatomy.
    Redlin M; Boettcher W; Huebler M; Berger F; Hetzer R; Koster A; Kuebler WM
    Ann Thorac Surg; 2006 Jul; 82(1):323-5. PubMed ID: 16798244
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cardiac Surgery-Associated Kidney Injury in Children and Renal Oximetry.
    Joffe R; Al Aklabi M; Bhattacharya S; Cave D; Calleja T; Garros D; Majesic N; Ryerson L; Morgan C
    Pediatr Crit Care Med; 2018 Sep; 19(9):839-845. PubMed ID: 30028784
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Regional differences in tissue oxygenation during cardiopulmonary bypass for correction of congenital heart disease in neonates and small infants: relevance of near-infrared spectroscopy.
    Redlin M; Koster A; Huebler M; Boettcher W; Nagdyman N; Hetzer R; Kuppe H; Kuebler WM
    J Thorac Cardiovasc Surg; 2008 Oct; 136(4):962-7. PubMed ID: 18954637
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Splanchnic near-infrared spectroscopy and risk of necrotizing enterocolitis after neonatal heart surgery.
    DeWitt AG; Charpie JR; Donohue JE; Yu S; Owens GE
    Pediatr Cardiol; 2014 Oct; 35(7):1286-94. PubMed ID: 24894893
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.