These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

388 related articles for article (PubMed ID: 32790734)

  • 1. Comparison of the MultiViewScope Stylet Scope and the direct laryngoscope with the Miller blade for the intubation in normal and difficult pediatric airways: A randomized, crossover, manikin study.
    Godai K; Moriyama T; Kanmura Y
    PLoS One; 2020; 15(8):e0237593. PubMed ID: 32790734
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of bonfils fiberscope-assisted laryngoscopy and standard direct laryngoscopy in simulated difficult pediatric intubation: a manikin study.
    Vlatten A; Aucoin S; Litz S; MacManus B; Soder C
    Paediatr Anaesth; 2010 Jun; 20(6):559-65. PubMed ID: 20412457
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Straight video blades are advantageous than curved blades in simulated pediatric difficult intubation.
    Saracoglu KT; Eti Z; Kavas AD; Umuroglu T
    Paediatr Anaesth; 2014 Mar; 24(3):297-302. PubMed ID: 24215652
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of Glidescope Core, C-MAC Miller and conventional Miller laryngoscope for difficult airway management by anesthetists with limited and extensive experience in a simulated Pierre Robin sequence: A randomized crossover manikin study.
    Moritz A; Holzhauser L; Fuchte T; Kremer S; Schmidt J; Irouschek A
    PLoS One; 2021; 16(4):e0250369. PubMed ID: 33886650
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
    Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
    Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Comparison of five video laryngoscopes and conventional direct laryngoscopy : Investigations on simple and simulated difficult airways on the intubation trainer].
    Ruetzler K; Imach S; Weiss M; Haas T; Schmidt AR
    Anaesthesist; 2015 Jul; 64(7):513-9. PubMed ID: 26174747
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Learning curve and performance in simulated difficult airway for the novel C-MAC® video-stylet and C-MAC® Macintosh video laryngoscope: A prospective randomized manikin trial.
    Pius J; Noppens RR
    PLoS One; 2020; 15(11):e0242154. PubMed ID: 33211728
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of the Truview PCD and the GlideScope Cobalt AVL video-laryngoscopes to the Miller blade for successfully intubating manikins simulating normal and difficult pediatric airways.
    Hippard HK; Kalyani G; Olutoye OA; Mann DG; Watcha MF
    Paediatr Anaesth; 2016 Jun; 26(6):613-20. PubMed ID: 27083381
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prospective model-based comparison of different laryngoscopes for difficult intubation in infants.
    Kalbhenn J; Boelke AK; Steinmann D
    Paediatr Anaesth; 2012 Aug; 22(8):776-80. PubMed ID: 22646973
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Which Device Is Favorable for Intubation Attempts of Pediatric Residents on Four Different Pediatric Airway Simulations?
    Er A; Çağlar A; Çitlenbik H; Akgül F; Ulusoy E; Ören H; Yιlmaz D; Duman M
    Pediatr Emerg Care; 2022 Jan; 38(1):e272-e277. PubMed ID: 33003132
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparison of the Trachway intubating stylet and the Macintosh laryngoscope in tracheal intubation: a manikin study.
    Hung KC; Tan PH; Lin VC; Wang HK; Chen HS
    J Anesth; 2013 Apr; 27(2):205-10. PubMed ID: 23053462
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparing the performance of traditional direct laryngoscope with three indirect laryngoscopes: A prospective manikin study in normal and difficult airway scenarios.
    Ong JR; Chong CF; Chen CC; Wang TL; Lin CM; Chang SC
    Emerg Med Australas; 2011 Oct; 23(5):606-14. PubMed ID: 21995476
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the king vision video laryngoscope with the macintosh laryngoscope.
    Murphy LD; Kovacs GJ; Reardon PM; Law JA
    J Emerg Med; 2014 Aug; 47(2):239-46. PubMed ID: 24742495
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways.
    van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M
    Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The efficacy of the Storz Miller 1 video laryngoscope in a simulated infant difficult intubation.
    Fiadjoe JE; Stricker PA; Hackell RS; Salam A; Gurnaney H; Rehman MA; Litman RS
    Anesth Analg; 2009 Jun; 108(6):1783-6. PubMed ID: 19448202
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of Coopdech videolaryngoscope: comparisons with a Macintosh laryngoscope and the Airway Scope in a manikin with difficult airways.
    Saito T; Asai T; Arai T; Tachikawa M; Shimazaki M; Okuda Y
    J Anesth; 2012 Aug; 26(4):617-20. PubMed ID: 22678515
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of Macintosh and Intubrite laryngoscopes for intubation performed by novice physicians in a difficult airway scenario.
    Szarpak L; Smereka J; Ladny JR
    Am J Emerg Med; 2017 May; 35(5):796-797. PubMed ID: 28139309
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Retromolar intubation with video intubating stylet in difficult airway: A randomized crossover manikin study.
    Chen YY; Lin JC; Tsai MJ; Cheng KY
    Am J Emerg Med; 2022 Apr; 54():212-220. PubMed ID: 35180667
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Airtraq Laryngoscope Versus the Conventional Macintosh Laryngoscope During Pediatric Intubation Performed by Nurses: A Randomized Crossover Manikin Study With Three Airway Scenarios.
    Szarpak Ł; Karczewska K; Czyżewski Ł; Truszewski Z; Kurowski A
    Pediatr Emerg Care; 2017 Nov; 33(11):735-739. PubMed ID: 27228145
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the Cobalt Glidescope video laryngoscope with conventional laryngoscopy in simulated normal and difficult infant airways.
    White M; Weale N; Nolan J; Sale S; Bayley G
    Paediatr Anaesth; 2009 Nov; 19(11):1108-12. PubMed ID: 19659602
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.