These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Structural testing of lower-limb prosthetic sockets: A systematic review. Gariboldi F; Pasquarelli D; Cutti AG Med Eng Phys; 2022 Jan; 99():103742. PubMed ID: 35058025 [TBL] [Abstract][Full Text] [Related]
24. A qualitative study on stakeholder perceptions of digital prosthetic socket fabrication for transtibial amputations. Mayo AL; Gould S; Cimino SR; Glasford S; Harvey E; Ratto M; Hitzig SL Prosthet Orthot Int; 2022 Dec; 46(6):607-613. PubMed ID: 36515905 [TBL] [Abstract][Full Text] [Related]
25. Mechanical testing of transtibial prosthetic sockets: A discussion paper from the American Orthotic and Prosthetic Association Socket Guidance Workgroup. Gariboldi F; Cutti AG; Fatone S; Nickel E; Dickinson A; Steer J; Erenstone J; Zahedi S; Prosthet Orthot Int; 2023 Feb; 47(1):3-12. PubMed ID: 36763513 [TBL] [Abstract][Full Text] [Related]
26. Transfemoral sockets with vacuum-assisted suspension comparison of hip kinematics, socket position, contact pressure, and preference: ischial containment versus brimless. Kahle JT; Highsmith MJ J Rehabil Res Dev; 2013; 50(9):1241-52. PubMed ID: 24458964 [TBL] [Abstract][Full Text] [Related]
27. Methods for characterization of mechanical and electrical prosthetic vacuum pumps. Komolafe O; Wood S; Caldwell R; Hansen A; Fatone S J Rehabil Res Dev; 2013; 50(8):1069-78. PubMed ID: 24458892 [TBL] [Abstract][Full Text] [Related]
28. A qualitative study exploring healthcare professionals' perceptions of lower limb 3D printed sockets. Li L; Miguel M; Phillips C; Verweel L; Wasilewski MB; MacKay C Disabil Rehabil; 2024 Aug; 46(17):4033-4039. PubMed ID: 37766382 [TBL] [Abstract][Full Text] [Related]
29. Clinical utility of pressure feedback to socket design and fabrication. Armitage L; Buller A; Rajan G; Prusty G; Simmons A; Kark L Prosthet Orthot Int; 2020 Feb; 44(1):18-26. PubMed ID: 31769736 [TBL] [Abstract][Full Text] [Related]
30. Preliminary Material Evaluation of Flax Fibers for Prosthetic Socket Fabrication. Monette D; Dumond P; Chikhaoui I; Nichols P; Lemaire ED J Biomech Eng; 2021 Feb; 143(2):. PubMed ID: 32793968 [TBL] [Abstract][Full Text] [Related]
32. Evaluation of a Prototype Hybrid Vacuum Pump to Provide Vacuum-Assisted Suspension for Above-Knee Prostheses. Major MJ; Caldwell R; Fatone S J Med Device; 2015 Dec; 9(4):0445041-445044. PubMed ID: 27462383 [TBL] [Abstract][Full Text] [Related]
33. Design of a novel prosthetic socket: assessment of the thermal performance. Webber CM; Davis BL J Biomech; 2015 May; 48(7):1294-9. PubMed ID: 25840507 [TBL] [Abstract][Full Text] [Related]
34. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets. Gerschutz MJ; Haynes ML; Nixon D; Colvin JM J Rehabil Res Dev; 2012; 49(3):405-26. PubMed ID: 22773200 [TBL] [Abstract][Full Text] [Related]
35. Optimal design and 3D printing of prosthetic socket based on the interface pressure between the socket and residual limb. Tang J; Liu X; Liu Z; Li W Prosthet Orthot Int; 2023 Feb; 47(1):87-93. PubMed ID: 35511448 [TBL] [Abstract][Full Text] [Related]
36. Quantitative and qualitative comparison of a new prosthetic suspension system with two existing suspension systems for lower limb amputees. Eshraghi A; Abu Osman NA; Karimi MT; Gholizadeh H; Ali S; Wan Abas WA Am J Phys Med Rehabil; 2012 Dec; 91(12):1028-38. PubMed ID: 23168378 [TBL] [Abstract][Full Text] [Related]
37. Comparative study of the circumferential and volumetric analysis between conventional casting and three-dimensional scanning methods for transtibial socket: A preliminary study. Mehmood W; Abd Razak NA; Lau MS; Chung TY; Gholizadeh H; Abu Osman NA Proc Inst Mech Eng H; 2019 Feb; 233(2):181-192. PubMed ID: 30518308 [TBL] [Abstract][Full Text] [Related]
38. Characterization of interfacial socket pressure in transhumeral prostheses: A case series. Schofield JS; Schoepp KR; Williams HE; Carey JP; Marasco PD; Hebert JS PLoS One; 2017; 12(6):e0178517. PubMed ID: 28575012 [TBL] [Abstract][Full Text] [Related]
39. A new approach for the pistoning measurement in transtibial prosthesis. Gholizadeh H; Abu Osman NA; Lúvíksdóttir Á; Eshraghi A; Kamyab M; Wan Abas WA Prosthet Orthot Int; 2011 Dec; 35(4):360-4. PubMed ID: 21975850 [TBL] [Abstract][Full Text] [Related]
40. Performance of an auto-adjusting prosthetic socket during walking with intermittent socket release. Weathersby EJ; Vamos AC; Larsen BG; McLean JB; Carter RV; Allyn KJ; Ballesteros D; Wang H; deGrasse NS; Friedly JL; Hafner BJ; Garbini JL; Ciol MA; Sanders JE J Rehabil Assist Technol Eng; 2022; 9():20556683221093271. PubMed ID: 35558157 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]