These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

253 related articles for article (PubMed ID: 32816234)

  • 21. Titanium vs. polyetheretherketone (PEEK) interbody fusion: Meta-analysis and review of the literature.
    Seaman S; Kerezoudis P; Bydon M; Torner JC; Hitchon PW
    J Clin Neurosci; 2017 Oct; 44():23-29. PubMed ID: 28736113
    [TBL] [Abstract][Full Text] [Related]  

  • 22. PEEK-Halo effect in interbody fusion.
    Phan K; Hogan JA; Assem Y; Mobbs RJ
    J Clin Neurosci; 2016 Feb; 24():138-40. PubMed ID: 26474500
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Additive-manufactured Ti-6Al-4 V/Polyetheretherketone composite porous cage for Interbody fusion: bone growth and biocompatibility evaluation in a porcine model.
    Tsai PI; Wu MH; Li YY; Lin TH; Tsai JSC; Huang HI; Lai HJ; Lee MH; Chen CY
    BMC Musculoskelet Disord; 2021 Feb; 22(1):171. PubMed ID: 33573634
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical rationale for using polyetheretherketone (PEEK) spacers for lumbar interbody fusion-A finite element study.
    Vadapalli S; Sairyo K; Goel VK; Robon M; Biyani A; Khandha A; Ebraheim NA
    Spine (Phila Pa 1976); 2006 Dec; 31(26):E992-8. PubMed ID: 17172990
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Spinal Implant Osseointegration and the Role of 3D Printing: An Analysis and Review of the Literature.
    Kia C; Antonacci CL; Wellington I; Makanji HS; Esmende SM
    Bioengineering (Basel); 2022 Mar; 9(3):. PubMed ID: 35324797
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Host bone response to polyetheretherketone versus porous tantalum implants for cervical spinal fusion in a goat model.
    Sinclair SK; Konz GJ; Dawson JM; Epperson RT; Bloebaum RD
    Spine (Phila Pa 1976); 2012 May; 37(10):E571-80. PubMed ID: 22146277
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Arthrodesis Rate and Patient Reported Outcomes After Anterior Lumbar Interbody Fusion Utilizing a Plasma-Sprayed Titanium Coated PEEK Interbody Implant: A Retrospective, Observational Analysis.
    Sclafani JA; Bergen SR; Staples M; Liang K; Raiszadeh R
    Int J Spine Surg; 2017; 11(1):4. PubMed ID: 28377862
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Evaluating Osseointegration Into a Deeply Porous Titanium Scaffold: A Biomechanical Comparison With PEEK and Allograft.
    Guyer RD; Abitbol JJ; Ohnmeiss DD; Yao C
    Spine (Phila Pa 1976); 2016 Oct; 41(19):E1146-E1150. PubMed ID: 27135643
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A porous bioactive titanium implant for spinal interbody fusion: an experimental study using a canine model.
    Takemoto M; Fujibayashi S; Neo M; So K; Akiyama N; Matsushita T; Kokubo T; Nakamura T
    J Neurosurg Spine; 2007 Oct; 7(4):435-43. PubMed ID: 17933320
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Characterization of thick titanium plasma spray coatings on PEEK materials used for medical implants and the influence on the mechanical properties.
    Vogel D; Dempwolf H; Baumann A; Bader R
    J Mech Behav Biomed Mater; 2018 Jan; 77():600-608. PubMed ID: 29096126
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Do Surface Porosity and Pore Size Influence Mechanical Properties and Cellular Response to PEEK?
    Torstrick FB; Evans NT; Stevens HY; Gall K; Guldberg RE
    Clin Orthop Relat Res; 2016 Nov; 474(11):2373-2383. PubMed ID: 27154533
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Combination Ti/PEEK ALIF cage for anterior lumbar interbody fusion: Early clinical and radiological results.
    Mobbs RJ; Phan K; Assem Y; Pelletier M; Walsh WR
    J Clin Neurosci; 2016 Dec; 34():94-99. PubMed ID: 27469413
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Interfacial shear strength of bioactive-coated carbon fiber reinforced polyetheretherketone after in vivo implantation.
    Nakahara I; Takao M; Goto T; Ohtsuki C; Hibino S; Sugano N
    J Orthop Res; 2012 Oct; 30(10):1618-25. PubMed ID: 22467537
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Getting PEEK to Stick to Bone: The Development of Porous PEEK for Interbody Fusion Devices.
    Torstrick FB; Safranski DL; Burkus JK; Chappuis JL; Lee CSD; Guldberg RE; Gall K; Smith KE
    Tech Orthop; 2017 Sep; 32(3):158-166. PubMed ID: 29225416
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface.
    Walsh WR; Bertollo N; Christou C; Schaffner D; Mobbs RJ
    Spine J; 2015 May; 15(5):1041-9. PubMed ID: 25543010
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Porous titanium-6 aluminum-4 vanadium cage has better osseointegration and less micromotion than a poly-ether-ether-ketone cage in sheep vertebral fusion.
    Wu SH; Li Y; Zhang YQ; Li XK; Yuan CF; Hao YL; Zhang ZY; Guo Z
    Artif Organs; 2013 Dec; 37(12):E191-201. PubMed ID: 24147953
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Three-Dimensional-Printed Titanium Versus Polyetheretherketone Cages for Lumbar Interbody Fusion: A Systematic Review of Comparative In Vitro, Animal, and Human Studies.
    Patel NA; O’Bryant S; Rogers CD; Boyett CK; Chakravarti S; Gendreau J; Brown NJ; Pennington ZA; Hatcher NB; Kuo C; Diaz-Aguilar LD; Pham MH
    Neurospine; 2023 Jun; 20(2):451-463. PubMed ID: 37401063
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Titanium versus polyetheretherketone implants for vertebral body replacement in the treatment of 77 thoracolumbar spinal fractures.
    Brandão RACS; Martins WCDS; Arantes AA; Gusmão SNS; Perrin G; Barrey C
    Surg Neurol Int; 2017; 8():191. PubMed ID: 28868203
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Surface Modification of Polyetheretherketone (PEEK) Intervertebral Fusion Implant Using Polydopamine Coating for Improved Bioactivity.
    Park S; Jung TG
    Bioengineering (Basel); 2024 Mar; 11(4):. PubMed ID: 38671765
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of Titanium Serum Levels in Patients After Spine Instrumentation: Comparison Between Posterolateral and 360º Spinal Fusion Surgery.
    Fernández Bances I; Paz Aparicio J; Alvarez Vega MA
    Cureus; 2019 Aug; 11(8):e5451. PubMed ID: 31511816
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.