These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 32827783)

  • 1. On the spectrographic representation of cardiovascular flow instabilities.
    Natarajan T; MacDonald DE; Najafi M; Khan MO; Steinman DA
    J Biomech; 2020 Sep; 110():109977. PubMed ID: 32827783
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On the prevalence of flow instabilities from high-fidelity computational fluid dynamics of intracranial bifurcation aneurysms.
    Khan MO; Toro Arana V; Najafi M; MacDonald DE; Natarajan T; Valen-Sendstad K; Steinman DA
    J Biomech; 2021 Oct; 127():110683. PubMed ID: 34454331
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison of the wavelet and short-time fourier transforms for Doppler spectral analysis.
    Zhang Y; Guo Z; Wang W; He S; Lee T; Loew M
    Med Eng Phys; 2003 Sep; 25(7):547-57. PubMed ID: 12835067
    [TBL] [Abstract][Full Text] [Related]  

  • 4. On the quantification and visualization of transient periodic instabilities in pulsatile flows.
    Khan MO; Chnafa C; Gallo D; Molinari F; Morbiducci U; Steinman DA; Valen-Sendstad K
    J Biomech; 2017 Feb; 52():179-182. PubMed ID: 28069165
    [TBL] [Abstract][Full Text] [Related]  

  • 5. High-resolution computational fluid dynamics detects flow instabilities in the carotid siphon: implications for aneurysm initiation and rupture?
    Valen-Sendstad K; Piccinelli M; Steinman DA
    J Biomech; 2014 Sep; 47(12):3210-6. PubMed ID: 25062933
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance of time-frequency representation techniques to measure blood flow turbulence with pulsed-wave Doppler ultrasound.
    Cloutier G; Chen D; Durand LG
    Ultrasound Med Biol; 2001 Apr; 27(4):535-50. PubMed ID: 11368865
    [TBL] [Abstract][Full Text] [Related]  

  • 7. STFT or CWT for the detection of Doppler ultrasound embolic signals.
    Gonçalves IB; Leiria A; Moura MM
    Int J Numer Method Biomed Eng; 2013 Sep; 29(9):964-76. PubMed ID: 23576393
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experimental and CFD flow studies in an intracranial aneurysm model with Newtonian and non-Newtonian fluids.
    Frolov SV; Sindeev SV; Liepsch D; Balasso A
    Technol Health Care; 2016 May; 24(3):317-33. PubMed ID: 26835725
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Direct numerical simulation of transitional flow in a patient-specific intracranial aneurysm.
    Valen-Sendstad K; Mardal KA; Mortensen M; Reif BA; Langtangen HP
    J Biomech; 2011 Nov; 44(16):2826-32. PubMed ID: 21924724
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Errors in power-law estimations of inflow rates for intracranial aneurysm CFD.
    Chnafa C; Bouillot P; Brina O; Najafi M; Delattre BMA; Vargas MI; Pereira VM; Steinman DA
    J Biomech; 2018 Oct; 80():159-165. PubMed ID: 30243498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of microvascular sutures on shear strain rate in realistic pulsatile flow.
    Wain RAJ; Smith DJ; Hammond DR; Whitty JPM
    Microvasc Res; 2018 Jul; 118():69-81. PubMed ID: 29522755
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Spectral broadening of ophthalmic arterial Doppler signals using STFT and wavelet transform.
    Ubeyli ED; Güler I
    Comput Biol Med; 2004 Jun; 34(4):345-54. PubMed ID: 15121004
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemodynamic and morphological characteristics of a growing cerebral aneurysm.
    Dabagh M; Nair P; Gounley J; Frakes D; Gonzalez LF; Randles A
    Neurosurg Focus; 2019 Jul; 47(1):E13. PubMed ID: 31261117
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Development of a System for Measuring Wall Shear Stress in Blood Vessels using Magnetic Resonance Imaging and Computational Fluid Dynamics.
    Yoshida K; Nagao T; Okada K; Miyazaki S; Yang X; Yamazaki Y; Murase K
    Igaku Butsuri; 2008; 27(3):136-49. PubMed ID: 18367824
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Analysis of wavelet scalogram of blood flow ultrasonic Doppler signal].
    Zhang P; Liu Y; Liu ZY; Shen Y; Yu JH
    Space Med Med Eng (Beijing); 2000 Apr; 13(2):119-23. PubMed ID: 11543050
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental and Numerical Analysis of the Bulk Flow Parameters Within an Arteriovenous Fistula.
    Browne LD; Walsh MT; Griffin P
    Cardiovasc Eng Technol; 2015 Dec; 6(4):450-62. PubMed ID: 26577478
    [TBL] [Abstract][Full Text] [Related]  

  • 17. High-resolution CFD detects high-frequency velocity fluctuations in bifurcation, but not sidewall, aneurysms.
    Valen-Sendstad K; Mardal KA; Steinman DA
    J Biomech; 2013 Jan; 46(2):402-7. PubMed ID: 23174422
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Doppler angle estimation of pulsatile flows using AR modeling.
    Yeh CK; Li PC
    Ultrason Imaging; 2002 Apr; 24(2):65-80. PubMed ID: 12199419
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Narrowing the Expertise Gap for Predicting Intracranial Aneurysm Hemodynamics: Impact of Solver Numerics versus Mesh and Time-Step Resolution.
    Khan MO; Valen-Sendstad K; Steinman DA
    AJNR Am J Neuroradiol; 2015 Jul; 36(7):1310-6. PubMed ID: 25742983
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Use of Continuous Wavelet Transform Based on the Fast Fourier Transform in the Analysis of Multi-channel Electrogastrography Recordings.
    Komorowski D; Pietraszek S
    J Med Syst; 2016 Jan; 40(1):10. PubMed ID: 26573647
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.