These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 32839823)

  • 1. Study on the Long Bone Failure Behaviors Under the Indenter Rigid-Contact by Experiment Analysis and Subject-Specific Simulation.
    Du X; Jiang B; Zhang G; Chou CC; Bai Z
    J Biomech Eng; 2021 Feb; 143(2):. PubMed ID: 32839823
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Study of indentation of a sample equine bone using finite element simulation and single cycle reference point indentation.
    Hoffseth K; Randall C; Hansma P; Yang HT
    J Mech Behav Biomed Mater; 2015 Feb; 42():282-91. PubMed ID: 25528690
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element prediction with experimental validation of damage distribution in single trabeculae during three-point bending tests.
    Ridha H; Thurner PJ
    J Mech Behav Biomed Mater; 2013 Nov; 27():94-106. PubMed ID: 23890577
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detailed subject-specific FE rib modeling for fracture prediction.
    Iraeus J; Lundin L; Storm S; Agnew A; Kang YS; Kemper A; Albert D; Holcombe S; Pipkorn B
    Traffic Inj Prev; 2019; 20(sup2):S88-S95. PubMed ID: 31589083
    [No Abstract]   [Full Text] [Related]  

  • 5. Finite element simulation of Reference Point Indentation on bone.
    Idkaidek A; Agarwal V; Jasiuk I
    J Mech Behav Biomed Mater; 2017 Jan; 65():574-583. PubMed ID: 27721174
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Importance of asymmetry and anisotropy in predicting cortical bone response and fracture using human body model femur in three-point bending and axial rotation.
    Khor F; Cronin DS; Watson B; Gierczycka D; Malcolm S
    J Mech Behav Biomed Mater; 2018 Nov; 87():213-229. PubMed ID: 30081355
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of friction on indenter force and pile-up in numerical simulations of bone nanoindentation.
    Adam CJ; Swain MV
    J Mech Behav Biomed Mater; 2011 Oct; 4(7):1554-8. PubMed ID: 21783165
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Modeling of Osteoprobe indentation on bone.
    Idkaidek A; Jasiuk I
    J Mech Behav Biomed Mater; 2019 Feb; 90():365-373. PubMed ID: 30399565
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Combining specimen-specific finite-element models and optimization in cortical-bone material characterization improves prediction accuracy in three-point bending tests.
    Zhang G; Xu S; Yang J; Guan F; Cao L; Mao H
    J Biomech; 2018 Jul; 76():103-111. PubMed ID: 29921522
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Implementation and validation of finite element model of skull deformation and failure response during uniaxial compression.
    Alexander SL; Weerasooriya T
    J Mech Behav Biomed Mater; 2021 Mar; 115():104302. PubMed ID: 33476873
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prediction of failure in cancellous bone using extended finite element method.
    Salem M; Westover L; Adeeb S; Duke K
    Proc Inst Mech Eng H; 2020 Sep; 234(9):988-999. PubMed ID: 32605523
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation of inner mechanism of anisotropic mechanical property of antler bone.
    Fang Z; Chen B; Lin S; Ye W; Xiao H; Chen X
    J Mech Behav Biomed Mater; 2018 Dec; 88():1-10. PubMed ID: 30114597
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Injury risk functions based on population-based finite element model responses: Application to femurs under dynamic three-point bending.
    Park G; Forman J; Kim T; Panzer MB; Crandall JR
    Traffic Inj Prev; 2018 Feb; 19(sup1):S59-S64. PubMed ID: 29584479
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones.
    Durham ME; Sod GA; Riggs LM; Mitchell CF
    Vet Surg; 2015 Feb; 44(2):206-13. PubMed ID: 25132492
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Determination of Mechanical and Fracture Properties of Silicon Single Crystal from Indentation Experiments and Finite Element Modelling.
    Skalka P; Kotoul M
    Materials (Basel); 2021 Nov; 14(22):. PubMed ID: 34832266
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessment of the effect of reduced compositional heterogeneity on fracture resistance of human cortical bone using finite element modeling.
    Demirtas A; Curran E; Ural A
    Bone; 2016 Oct; 91():92-101. PubMed ID: 27451083
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element analysis of pedestrian lower limb fractures by direct force: the result of being run over or impact?
    Li Z; Zou D; Liu N; Zhong L; Shao Y; Wan L; Huang P; Chen Y
    Forensic Sci Int; 2013 Jun; 229(1-3):43-51. PubMed ID: 23683907
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Age dependent mechanical properties of the infant porcine parietal bone and a correlation to the human.
    Baumer TG; Powell BJ; Fenton TW; Haut RC
    J Biomech Eng; 2009 Nov; 131(11):111006. PubMed ID: 20353257
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Influence of bone defect position and span in 3-point bending tests: experimental and finite element analysis.
    Osuna LGG; Soares CJ; Vilela ABF; Irie MS; Versluis A; Soares PBF
    Braz Oral Res; 2020; 35():e001. PubMed ID: 33206774
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mixed-mode I+II fracture characterization of human cortical bone using the Single Leg Bending test.
    Silva FG; de Moura MF; Dourado N; Xavier J; Pereira FA; Morais JJ; Dias MI
    J Mech Behav Biomed Mater; 2016 Feb; 54():72-81. PubMed ID: 26433088
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.