BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

294 related articles for article (PubMed ID: 32860322)

  • 1. Effect of Device Configuration and Patient's Body Composition on the RF Heating and Nonsusceptibility Artifact of Deep Brain Stimulation Implants During MRI at 1.5T and 3T.
    Bhusal B; Nguyen BT; Sanpitak PP; Vu J; Elahi B; Rosenow J; Nolt MJ; Lopez-Rosado R; Pilitsis J; DiMarzio M; Golestanirad L
    J Magn Reson Imaging; 2021 Feb; 53(2):599-610. PubMed ID: 32860322
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Device Configuration and Patient's Body Composition Significantly Affect RF Heating of Deep Brain Stimulation Implants During MRI: An Experimental Study at 1.5T and 3T.
    Bhusal B; Nguyen BT; Vu J; Elahi B; Rosenow J; Nolt MJ; Pilitsis J; DiMarzio M; Golestanirad L
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():5192-5197. PubMed ID: 33019155
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of surgical modification of deep brain stimulation lead trajectories on radiofrequency heating during MRI at 3T: from phantom experiments to clinical implementation.
    Vu J; Bhusal B; Rosenow JM; Pilitsis J; Golestanirad L
    J Neurosurg; 2024 May; 140(5):1459-1470. PubMed ID: 37948679
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Vertical open-bore MRI scanners generate significantly less radiofrequency heating around implanted leads: A study of deep brain stimulation implants in 1.2T OASIS scanners versus 1.5T horizontal systems.
    Kazemivalipour E; Bhusal B; Vu J; Lin S; Nguyen BT; Kirsch J; Nowac E; Pilitsis J; Rosenow J; Atalar E; Golestanirad L
    Magn Reson Med; 2021 Sep; 86(3):1560-1572. PubMed ID: 33961301
    [TBL] [Abstract][Full Text] [Related]  

  • 5. RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5 T and 3T: The role of surgical lead management.
    Golestanirad L; Kirsch J; Bonmassar G; Downs S; Elahi B; Martin A; Iacono MI; Angelone LM; Keil B; Wald LL; Pilitsis J
    Neuroimage; 2019 Jan; 184():566-576. PubMed ID: 30243973
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Editorial for "Effect of Device Configuration and Patient's Body Composition on the Nonsusceptibility Artifact and RF Heating of Deep Brain Stimulation Devices During MRI at 1.5T and 3T".
    Kremser C
    J Magn Reson Imaging; 2021 Feb; 53(2):611-612. PubMed ID: 32851743
    [No Abstract]   [Full Text] [Related]  

  • 7. A comparative study of RF heating of deep brain stimulation devices in vertical vs. horizontal MRI systems.
    Vu J; Bhusal B; Nguyen BT; Sanpitak P; Nowac E; Pilitsis J; Rosenow J; Golestanirad L
    PLoS One; 2022; 17(12):e0278187. PubMed ID: 36490249
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The Safety of Using Body-Transmit MRI in Patients with Implanted Deep Brain Stimulation Devices.
    Kahan J; Papadaki A; White M; Mancini L; Yousry T; Zrinzo L; Limousin P; Hariz M; Foltynie T; Thornton J
    PLoS One; 2015; 10(6):e0129077. PubMed ID: 26061738
    [TBL] [Abstract][Full Text] [Related]  

  • 9. RF heating of deep brain stimulation implants in open-bore vertical MRI systems: A simulation study with realistic device configurations.
    Golestanirad L; Kazemivalipour E; Lampman D; Habara H; Atalar E; Rosenow J; Pilitsis J; Kirsch J
    Magn Reson Med; 2020 Jun; 83(6):2284-2292. PubMed ID: 31677308
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Patient's body composition can significantly affect RF power deposition in the tissue around DBS implants: ramifications for lead management strategies and MRI field-shaping techniques.
    Bhusal B; Keil B; Rosenow J; Kazemivalipour E; Golestanirad L
    Phys Med Biol; 2021 Jan; 66(1):015008. PubMed ID: 33238247
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A simple geometric analysis method for measuring and mitigating RF induced currents on Deep Brain Stimulation leads by multichannel transmission/reception.
    Eryaman Y; Kobayashi N; Moen S; Aman J; Grant A; Vaughan JT; Molnar G; Park MC; Vitek J; Adriany G; Ugurbil K; Harel N
    Neuroimage; 2019 Jan; 184():658-668. PubMed ID: 30273715
    [TBL] [Abstract][Full Text] [Related]  

  • 12. RF heating of deep brain stimulation implants during MRI in 1.2 T vertical scanners versus 1.5 T horizontal systems: A simulation study with realistic lead configurations.
    Kazemivalipour E; Vu J; Lin S; Bhusal B; Thanh Nguyen B; Kirsch J; Elahi B; Rosenow J; Atalar E; Golestanirad L
    Annu Int Conf IEEE Eng Med Biol Soc; 2020 Jul; 2020():6143-6146. PubMed ID: 33019373
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modifying surgical implantation of deep brain stimulation leads significantly reduces RF-induced heating during 3 T MRI.
    Vu J; Bhusal B; Rosenow J; Pilitsis J; Golestanirad L
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():4978-4981. PubMed ID: 34892325
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technical Note: An anthropomorphic phantom with implanted neurostimulator for investigation of MRI safety.
    Yang B; Tam F; Davidson B; Wei PS; Hamani C; Lipsman N; Chen CH; Graham SJ
    Med Phys; 2020 Aug; 47(8):3745-3751. PubMed ID: 32350868
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 3-Tesla MRI in patients with fully implanted deep brain stimulation devices: a preliminary study in 10 patients.
    Sammartino F; Krishna V; Sankar T; Fisico J; Kalia SK; Hodaie M; Kucharczyk W; Mikulis DJ; Crawley A; Lozano AM
    J Neurosurg; 2017 Oct; 127(4):892-898. PubMed ID: 28009238
    [TBL] [Abstract][Full Text] [Related]  

  • 16. 3-Tesla MRI of deep brain stimulation patients: safety assessment of coils and pulse sequences.
    Boutet A; Hancu I; Saha U; Crawley A; Xu DS; Ranjan M; Hlasny E; Chen R; Foltz W; Sammartino F; Coblentz A; Kucharczyk W; Lozano AM
    J Neurosurg; 2019 Feb; 132(2):586-594. PubMed ID: 30797197
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimizing the trajectory of deep brain stimulation leads reduces RF heating during MRI at 3 T: Characteristics and clinical translation.
    Vu J; Bhusal B; Rosenow J; Pilitsis J; Golestanirad L
    Annu Int Conf IEEE Eng Med Biol Soc; 2023 Jul; 2023():1-5. PubMed ID: 38083480
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Safety and image quality at 7T MRI for deep brain stimulation systems: Ex vivo study with lead-only and full-systems.
    Bhusal B; Stockmann J; Guerin B; Mareyam A; Kirsch J; Wald LL; Nolt MJ; Rosenow J; Lopez-Rosado R; Elahi B; Golestanirad L
    PLoS One; 2021; 16(9):e0257077. PubMed ID: 34492090
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reconfigurable MRI technology for low-SAR imaging of deep brain stimulation at 3T: Application in bilateral leads, fully-implanted systems, and surgically modified lead trajectories.
    Kazemivalipour E; Keil B; Vali A; Rajan S; Elahi B; Atalar E; Wald LL; Rosenow J; Pilitsis J; Golestanirad L
    Neuroimage; 2019 Oct; 199():18-29. PubMed ID: 31096058
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Three-Tesla Magnetic Resonance Imaging of Patients With Deep Brain Stimulators: Results From a Phantom Study and a Pilot Study in Patients.
    Davidson B; Tam F; Yang B; Meng Y; Hamani C; Graham SJ; Lipsman N
    Neurosurgery; 2021 Jan; 88(2):349-355. PubMed ID: 33045736
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.