These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 32866089)

  • 1. How good are my data? Reference standards in superresolution microscopy.
    Mund M; Ries J
    Mol Biol Cell; 2020 Sep; 31(19):2093-2096. PubMed ID: 32866089
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Nuclear pores as versatile reference standards for quantitative superresolution microscopy.
    Thevathasan JV; Kahnwald M; Cieśliński K; Hoess P; Peneti SK; Reitberger M; Heid D; Kasuba KC; Hoerner SJ; Li Y; Wu YL; Mund M; Matti U; Pereira PM; Henriques R; Nijmeijer B; Kueblbeck M; Sabinina VJ; Ellenberg J; Ries J
    Nat Methods; 2019 Oct; 16(10):1045-1053. PubMed ID: 31562488
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Superresolution imaging with standard fluorescent probes.
    Millis BA; Burnette DT; Lippincott-Schwartz J; Kachar B
    Curr Protoc Cell Biol; 2013 Sep; 60():21.8.1-21.8.17. PubMed ID: 24510788
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Toward quantitative fluorescence microscopy with DNA origami nanorulers.
    Beater S; Raab M; Tinnefeld P
    Methods Cell Biol; 2014; 123():449-66. PubMed ID: 24974042
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Confocal Reflection Super-Resolution Technique to Image Golgi-Cox Stained Neurons.
    Sivaguru M; Khaw YM; Inoue M
    J Microsc; 2019 Aug; 275(2):115-130. PubMed ID: 31237354
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Using DNA origami nanorulers as traceable distance measurement standards and nanoscopic benchmark structures.
    Raab M; Jusuk I; Molle J; Buhr E; Bodermann B; Bergmann D; Bosse H; Tinnefeld P
    Sci Rep; 2018 Jan; 8(1):1780. PubMed ID: 29379061
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Superresolution imaging with optical fluctuation using speckle patterns illumination.
    Kim M; Park C; Rodriguez C; Park Y; Cho YH
    Sci Rep; 2015 Nov; 5():16525. PubMed ID: 26572283
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Superresolution fluorescence microscopy for 3D reconstruction of thick samples.
    Park S; Kang W; Kwon YD; Shim J; Kim S; Kaang BK; Hohng S
    Mol Brain; 2018 Mar; 11(1):17. PubMed ID: 29544505
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Superresolution optical fluctuation imaging (SOFI).
    Dertinger T; Colyer R; Vogel R; Heilemann M; Sauer M; Enderlein J; Weiss S
    Adv Exp Med Biol; 2012; 733():17-21. PubMed ID: 22101708
    [TBL] [Abstract][Full Text] [Related]  

  • 10. QUAREP-LiMi: A community-driven initiative to establish guidelines for quality assessment and reproducibility for instruments and images in light microscopy.
    Nelson G; Boehm U; Bagley S; Bajcsy P; Bischof J; Brown CM; Dauphin A; Dobbie IM; Eriksson JE; Faklaris O; Fernandez-Rodriguez J; Ferrand A; Gelman L; Gheisari A; Hartmann H; Kukat C; Laude A; Mitkovski M; Munck S; North AJ; Rasse TM; Resch-Genger U; Schuetz LC; Seitz A; Strambio-De-Castillia C; Swedlow JR; Alexopoulos I; Aumayr K; Avilov S; Bakker GJ; Bammann RR; Bassi A; Beckert H; Beer S; Belyaev Y; Bierwagen J; Birngruber KA; Bosch M; Breitlow J; Cameron LA; Chalfoun J; Chambers JJ; Chen CL; Conde-Sousa E; Corbett AD; Cordelieres FP; Nery ED; Dietzel R; Eismann F; Fazeli E; Felscher A; Fried H; Gaudreault N; Goh WI; Guilbert T; Hadleigh R; Hemmerich P; Holst GA; Itano MS; Jaffe CB; Jambor HK; Jarvis SC; Keppler A; Kirchenbuechler D; Kirchner M; Kobayashi N; Krens G; Kunis S; Lacoste J; Marcello M; Martins GG; Metcalf DJ; Mitchell CA; Moore J; Mueller T; Nelson MS; Ogg S; Onami S; Palmer AL; Paul-Gilloteaux P; Pimentel JA; Plantard L; Podder S; Rexhepaj E; Royon A; Saari MA; Schapman D; Schoonderwoert V; Schroth-Diez B; Schwartz S; Shaw M; Spitaler M; Stoeckl MT; Sudar D; Teillon J; Terjung S; Thuenauer R; Wilms CD; Wright GD; Nitschke R
    J Microsc; 2021 Oct; 284(1):56-73. PubMed ID: 34214188
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Quantitative image correction and calibration for confocal fluorescence microscopy using thin reference layers and SIPchart-based calibration procedures.
    Zwier JM; Oomen L; Brocks L; Jalink K; Brakenhoff GJ
    J Microsc; 2008 Jul; 231(Pt 1):59-69. PubMed ID: 18638190
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Excitation-multiplexed multicolor superresolution imaging with fm-STORM and fm-DNA-PAINT.
    Gómez-García PA; Garbacik ET; Otterstrom JJ; Garcia-Parajo MF; Lakadamyali M
    Proc Natl Acad Sci U S A; 2018 Dec; 115(51):12991-12996. PubMed ID: 30509979
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Standardization of fluorescence measurements: criteria for the choice of suitable standards and approaches to fit-for-purpose calibration tools.
    Resch-Genger U; Hoffmann K; Hoffmann A
    Ann N Y Acad Sci; 2008; 1130():35-43. PubMed ID: 18596329
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Superresolution Imaging of Cytoskeletal Networks in Fixed Brain Tissue.
    Hicks AI; Zhou S; Yang J; Prager-Khoutorsky M
    Methods Mol Biol; 2022; 2515():171-191. PubMed ID: 35776352
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-numerical-aperture cryogenic light microscopy for increased precision of superresolution reconstructions.
    Nahmani M; Lanahan C; DeRosier D; Turrigiano GG
    Proc Natl Acad Sci U S A; 2017 Apr; 114(15):3832-3836. PubMed ID: 28348224
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Resolving single-molecule assembled patterns with superresolution blink-microscopy.
    Cordes T; Strackharn M; Stahl SW; Summerer W; Steinhauer C; Forthmann C; Puchner EM; Vogelsang J; Gaub HE; Tinnefeld P
    Nano Lett; 2010 Feb; 10(2):645-51. PubMed ID: 20017533
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An automated protocol for performance benchmarking a widefield fluorescence microscope.
    Halter M; Bier E; DeRose PC; Cooksey GA; Choquette SJ; Plant AL; Elliott JT
    Cytometry A; 2014 Nov; 85(11):978-85. PubMed ID: 25132217
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantitative studies of immunofluorescent staining. VII. Quantitative reference standard slide for standardization of fluorescence microscopes.
    Rostami R; Beutner EH; Kumar V
    Int Arch Allergy Immunol; 1992; 98(3):200-4. PubMed ID: 1382744
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Whole-cell, multicolor superresolution imaging using volumetric multifocus microscopy.
    Hajj B; Wisniewski J; El Beheiry M; Chen J; Revyakin A; Wu C; Dahan M
    Proc Natl Acad Sci U S A; 2014 Dec; 111(49):17480-5. PubMed ID: 25422417
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Structural anisotropy quantification improves the final superresolution image of localization microscopy.
    Wang Y; Huang ZL
    J Biomed Opt; 2016 Jul; 21(7):76011. PubMed ID: 27435898
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.