These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
309 related articles for article (PubMed ID: 32866216)
1. Concurrent heart rate validity of wearable technology devices during trail running. Navalta JW; Montes J; Bodell NG; Salatto RW; Manning JW; DeBeliso M PLoS One; 2020; 15(8):e0238569. PubMed ID: 32866216 [TBL] [Abstract][Full Text] [Related]
2. Validation of Polar OH1 optical heart rate sensor for moderate and high intensity physical activities. Hettiarachchi IT; Hanoun S; Nahavandi D; Nahavandi S PLoS One; 2019; 14(5):e0217288. PubMed ID: 31120968 [TBL] [Abstract][Full Text] [Related]
3. Accuracy of Consumer Wearable Heart Rate Measurement During an Ecologically Valid 24-Hour Period: Intraindividual Validation Study. Nelson BW; Allen NB JMIR Mhealth Uhealth; 2019 Mar; 7(3):e10828. PubMed ID: 30855232 [TBL] [Abstract][Full Text] [Related]
4. Accuracy of Optical Heart Rate Sensing Technology in Wearable Fitness Trackers for Young and Older Adults: Validation and Comparison Study. Chow HW; Yang CC JMIR Mhealth Uhealth; 2020 Apr; 8(4):e14707. PubMed ID: 32343255 [TBL] [Abstract][Full Text] [Related]
5. Accuracy of Apple Watch Measurements for Heart Rate and Energy Expenditure in Patients With Cardiovascular Disease: Cross-Sectional Study. Falter M; Budts W; Goetschalckx K; Cornelissen V; Buys R JMIR Mhealth Uhealth; 2019 Mar; 7(3):e11889. PubMed ID: 30888332 [TBL] [Abstract][Full Text] [Related]
6. Measurement of Heart Rate Using the Polar OH1 and Fitbit Charge 3 Wearable Devices in Healthy Adults During Light, Moderate, Vigorous, and Sprint-Based Exercise: Validation Study. Muggeridge DJ; Hickson K; Davies AV; Giggins OM; Megson IL; Gorely T; Crabtree DR JMIR Mhealth Uhealth; 2021 Mar; 9(3):e25313. PubMed ID: 33764310 [TBL] [Abstract][Full Text] [Related]
7. Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise. Gillinov S; Etiwy M; Wang R; Blackburn G; Phelan D; Gillinov AM; Houghtaling P; Javadikasgari H; Desai MY Med Sci Sports Exerc; 2017 Aug; 49(8):1697-1703. PubMed ID: 28709155 [TBL] [Abstract][Full Text] [Related]
8. Assessment of step accuracy using the Consumer Technology Association standard. Bunn JA; Jones C; Oliviera A; Webster MJ J Sports Sci; 2019 Feb; 37(3):244-248. PubMed ID: 29958058 [TBL] [Abstract][Full Text] [Related]
9. Accuracy of Wearable Devices for Measuring Heart Rate During Conventional and Nordic Walking. Baek S; Ha Y; Park HW PM R; 2021 Apr; 13(4):379-386. PubMed ID: 32449291 [TBL] [Abstract][Full Text] [Related]
10. Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities. Claes J; Buys R; Avila A; Finlay D; Kennedy A; Guldenring D; Budts W; Cornelissen V J Med Eng Technol; 2017 Aug; 41(6):480-485. PubMed ID: 28675070 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of Earbud and Wristwatch Heart Rate Monitors during Aerobic and Resistance Training. Bunn J; Wells E; Manor J; Webster M Int J Exerc Sci; 2019; 12(4):374-384. PubMed ID: 30899350 [TBL] [Abstract][Full Text] [Related]
12. Heart Rate Measures From Wrist-Worn Activity Trackers in a Laboratory and Free-Living Setting: Validation Study. Müller AM; Wang NX; Yao J; Tan CS; Low ICC; Lim N; Tan J; Tan A; Müller-Riemenschneider F JMIR Mhealth Uhealth; 2019 Oct; 7(10):e14120. PubMed ID: 31579026 [TBL] [Abstract][Full Text] [Related]
13. Estimating Accuracy at Exercise Intensities: A Comparative Study of Self-Monitoring Heart Rate and Physical Activity Wearable Devices. Dooley EE; Golaszewski NM; Bartholomew JB JMIR Mhealth Uhealth; 2017 Mar; 5(3):e34. PubMed ID: 28302596 [TBL] [Abstract][Full Text] [Related]
14. The accuracy of fitness watches for the measurement of heart rate and energy expenditure during moderate intensity exercise. Jagim AR; Koch-Gallup N; Camic CL; Kroening L; Nolte C; Schroeder C; Gran L; Erickson JL J Sports Med Phys Fitness; 2021 Feb; 61(2):205-211. PubMed ID: 32734757 [TBL] [Abstract][Full Text] [Related]
15. Assessing the Validity of Several Heart Rate Monitors in Wearable Technology While Mountain Biking. Carrier B; Salatto RW; Davis DW; Sertic JVL; Barrios B; McGinnis GR; Girouard TJ; Burroughs B; Navalta JW Int J Exerc Sci; 2023; 16(7):1440-1450. PubMed ID: 38287935 [TBL] [Abstract][Full Text] [Related]
16. Validity of Wearable Activity Monitors during Cycling and Resistance Exercise. Boudreaux BD; Hebert EP; Hollander DB; Williams BM; Cormier CL; Naquin MR; Gillan WW; Gusew EE; Kraemer RR Med Sci Sports Exerc; 2018 Mar; 50(3):624-633. PubMed ID: 29189666 [TBL] [Abstract][Full Text] [Related]
17. Wristbands in Home-Based Rehabilitation-Validation of Heart Rate Measurement. Jachymek M; Jachymek MT; Kiedrowicz RM; Kaźmierczak J; Płońska-Gościniak E; Peregud-Pogorzelska M Sensors (Basel); 2021 Dec; 22(1):. PubMed ID: 35009603 [TBL] [Abstract][Full Text] [Related]
18. Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities. Shumate T; Link M; Furness J; Kemp-Smith K; Simas V; Climstein M PeerJ; 2021; 9():e10893. PubMed ID: 33614295 [TBL] [Abstract][Full Text] [Related]
19. Wrist-Worn Wearables for Monitoring Heart Rate and Energy Expenditure While Sitting or Performing Light-to-Vigorous Physical Activity: Validation Study. Düking P; Giessing L; Frenkel MO; Koehler K; Holmberg HC; Sperlich B JMIR Mhealth Uhealth; 2020 May; 8(5):e16716. PubMed ID: 32374274 [TBL] [Abstract][Full Text] [Related]
20. Validity of the Polar H10 Sensor for Heart Rate Variability Analysis during Resting State and Incremental Exercise in Recreational Men and Women. Schaffarczyk M; Rogers B; Reer R; Gronwald T Sensors (Basel); 2022 Aug; 22(17):. PubMed ID: 36081005 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]