426 related articles for article (PubMed ID: 32867184)
21. Investigation of photoplethysmography and near infrared spectroscopy for the assessment of tissue blood perfusion.
Abay TY; Kyriacou PA
Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():5361-4. PubMed ID: 25571205
[TBL] [Abstract][Full Text] [Related]
22. Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care.
Yaqub MA; Zanoletti M; Cortese L; Sánchez DS; Amendola C; Frabasile L; Karadeniz U; Garcia JM; Martin M; Cortes-Picas J; Caballer A; Cortes E; Nogales S; Tosi A; Carteano T; Garcia DS; Tomanik J; Wagenaar T; Mui H; Guadagno CN; Parsa S; Venkata Sekar SK; Demarteau L; Houtbeckers T; Weigel UM; Lacerenza M; Buttafava M; Torricelli A; Contini D; Mesquida J; Durduran T
J Vis Exp; 2024 May; (207):. PubMed ID: 38801263
[TBL] [Abstract][Full Text] [Related]
23. Tissue hemoglobin O2 saturation during resuscitation of traumatic shock monitored using near infrared spectrometry.
McKinley BA; Marvin RG; Cocanour CS; Moore FA
J Trauma; 2000 Apr; 48(4):637-42. PubMed ID: 10780595
[TBL] [Abstract][Full Text] [Related]
24. Near-infrared oximetry of the brain.
Madsen PL; Secher NH
Prog Neurobiol; 1999 Aug; 58(6):541-60. PubMed ID: 10408656
[TBL] [Abstract][Full Text] [Related]
25. Simulation of oxygen saturation measurement in a single blood vein.
Duadi H; Nitzan M; Fixler D
Opt Lett; 2016 Sep; 41(18):4312-5. PubMed ID: 27628385
[TBL] [Abstract][Full Text] [Related]
26. Direct Measurement of Tissue Oxygenation in Neonates via Resonance Raman Spectroscopy: A Pilot Study.
Iyengar A; Gaillardetz A; Tighiouart H; Castillo B; Romfh P; Davis JM
Neonatology; 2017; 112(2):137-142. PubMed ID: 28514777
[TBL] [Abstract][Full Text] [Related]
27. Measurement of venous oxyhaemoglobin saturation in the adult human forearm by near infrared spectroscopy with venous occlusion.
Yoxall CW; Weindling AM
Med Biol Eng Comput; 1997 Jul; 35(4):331-6. PubMed ID: 9327608
[TBL] [Abstract][Full Text] [Related]
28. Investigation of photoplethysmography, laser doppler flowmetry and near infrared spectroscopy during induced thermal stress.
Budidha K; Abay TY; Kyriacou PA
Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():6417-20. PubMed ID: 26737761
[TBL] [Abstract][Full Text] [Related]
29. Near-Infrared Spectroscopy (NIRS) for Cerebral and Tissue Oximetry: Analysis of Evolving Applications.
Ali J; Cody J; Maldonado Y; Ramakrishna H
J Cardiothorac Vasc Anesth; 2022 Aug; 36(8 Pt A):2758-2766. PubMed ID: 34362641
[TBL] [Abstract][Full Text] [Related]
30. Validation of oxygen saturation monitoring in neonates.
Shiao SY; Ou CN
Am J Crit Care; 2007 Mar; 16(2):168-78. PubMed ID: 17322018
[TBL] [Abstract][Full Text] [Related]
31. Study protocol for the PHANTOM study: prehospital assessment of noninvasive tissue oximetry monitoring.
Weatherall A; Garner A; Lovell N; Redmond S; Lee A; Skowno J; Egan J
Scand J Trauma Resusc Emerg Med; 2014 Oct; 22():57. PubMed ID: 25280485
[TBL] [Abstract][Full Text] [Related]
32. Cerebral tissue oxygen saturation calculated using low frequency haemoglobin oscillations measured by near infrared spectroscopy in adult ventilated patients.
Leung TS; Tisdall MM; Tachtsidis I; Smith M; Delpy DT; Elwell CE
Adv Exp Med Biol; 2008; 614():235-44. PubMed ID: 18290334
[TBL] [Abstract][Full Text] [Related]
33. Arterial and venous contributions to near-infrared cerebral oximetry.
Watzman HM; Kurth CD; Montenegro LM; Rome J; Steven JM; Nicolson SC
Anesthesiology; 2000 Oct; 93(4):947-53. PubMed ID: 11020744
[TBL] [Abstract][Full Text] [Related]
34. Approaches for calibration and validation of near-infrared optical methods for oxygenation monitoring.
Hornberger C; Wabnitz H
Biomed Tech (Berl); 2018 Oct; 63(5):537-546. PubMed ID: 29425103
[TBL] [Abstract][Full Text] [Related]
35. T
Alderliesten T; De Vis JB; Lemmers PMA; van Bel F; Benders MJNL; Hendrikse J; Petersen ET
Neuroimage; 2016 Oct; 139():65-73. PubMed ID: 27291495
[TBL] [Abstract][Full Text] [Related]
36. Development of a new instrument to measure oxygen saturation and total hemoglobin volume in local skin by near-infrared spectroscopy and its clinical application.
Nagashima Y; Yada Y; Hattori M; Sakai A
Int J Biometeorol; 2000 May; 44(1):11-9. PubMed ID: 10879423
[TBL] [Abstract][Full Text] [Related]
37. Cerebral near-infrared spectroscopy insensitively detects low cerebral venous oxygen saturations after stage 1 palliation.
Rescoe E; Tang X; Perry DA; Sleeper LA; DiNardo JA; Kussman BD; Kheir JN
J Thorac Cardiovasc Surg; 2017 Sep; 154(3):1056-1062. PubMed ID: 28599970
[TBL] [Abstract][Full Text] [Related]
38. [Monitoring cerebral oxygenation using near infrared spectroscopy during cardiopulmonary bypass surgery].
Teng YC; Ding HS; Gong QC; Jia ZS; Huang L; Wang PY
Guang Pu Xue Yu Guang Pu Fen Xi; 2006 May; 26(5):828-32. PubMed ID: 16883847
[TBL] [Abstract][Full Text] [Related]
39. Interference of cerebral near-infrared oximetry in patients with icterus.
Madsen PL; Skak C; Rasmussen A; Secher NH
Anesth Analg; 2000 Feb; 90(2):489-93. PubMed ID: 10648345
[TBL] [Abstract][Full Text] [Related]
40. Relation of cerebral tissue oxygenation index to central venous oxygen saturation in children.
Nagdyman N; Fleck T; Barth S; Abdul-Khaliq H; Stiller B; Ewert P; Huebler M; Kuppe H; Lange PE
Intensive Care Med; 2004 Mar; 30(3):468-71. PubMed ID: 14722637
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]