These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
216 related articles for article (PubMed ID: 32871541)
1. Retrieval study of commercially available knee implant coatings TiN, TiNbN and ZrN on TiAl6V4 and CoCr28Mo6. Herbster M; Döring J; Nohava J; Lohmann CH; Halle T; Bertrand J J Mech Behav Biomed Mater; 2020 Dec; 112():104034. PubMed ID: 32871541 [TBL] [Abstract][Full Text] [Related]
2. Characteristics of different cathodic arc deposition coatings on CoCrMo for biomedical applications. Döring J; Crackau M; Nestler C; Welzel F; Bertrand J; Lohmann CH J Mech Behav Biomed Mater; 2019 Sep; 97():212-221. PubMed ID: 31129165 [TBL] [Abstract][Full Text] [Related]
3. Tribological characterization of zirconia coatings deposited on Ti6Al4V components for orthopedic applications. Berni M; Lopomo N; Marchiori G; Gambardella A; Boi M; Bianchi M; Visani A; Pavan P; Russo A; Marcacci M Mater Sci Eng C Mater Biol Appl; 2016 May; 62():643-55. PubMed ID: 26952468 [TBL] [Abstract][Full Text] [Related]
6. Current status and future potential of wear-resistant coatings and articulating surfaces for hip and knee implants. Skjöldebrand C; Tipper JL; Hatto P; Bryant M; Hall RM; Persson C Mater Today Bio; 2022 Jun; 15():100270. PubMed ID: 35601891 [TBL] [Abstract][Full Text] [Related]
7. Potential for adhesive wear in friction couples of UHMWPE running against oxidized zirconium, titanium nitride coatings, and cobalt-chromium alloys. Galetz MC; Seiferth SH; Theile B; Glatzel U J Biomed Mater Res B Appl Biomater; 2010 May; 93(2):468-75. PubMed ID: 20186822 [TBL] [Abstract][Full Text] [Related]
8. Retrieval Analysis of Titanium Nitride Coatings for Orthopaedic Implants. Basgul C; MacDonald DW; Klein GR; Piuzzi NS; Kurtz SM J Arthroplasty; 2024 Sep; 39(9S1):S272-S279. PubMed ID: 39019413 [TBL] [Abstract][Full Text] [Related]
9. CoCrMo alloys ions release behavior by TiNbN coating: an in vitro study. Ragone V; Canciani E; Biffi CA; D'Ambrosi R; Sanvito R; Dellavia C; Galliera E Biomed Microdevices; 2019 Jul; 21(3):61. PubMed ID: 31273538 [TBL] [Abstract][Full Text] [Related]
10. Retrieval analysis of TiN (titanium nitride) coated knee replacements: Coating wear and degradation in vivo. Łapaj Ł; Rozwalka J J Biomed Mater Res B Appl Biomater; 2020 May; 108(4):1251-1261. PubMed ID: 31471956 [TBL] [Abstract][Full Text] [Related]
11. Abrasion resistance of oxidized zirconium in comparison with CoCrMo and titanium nitride coatings for artificial knee joints. Galetz MC; Fleischmann EW; Konrad CH; Schuetz A; Glatzel U J Biomed Mater Res B Appl Biomater; 2010 Apr; 93(1):244-51. PubMed ID: 20162723 [TBL] [Abstract][Full Text] [Related]
12. High wear resistance of femoral components coated with titanium nitride: a retrieval analysis. Fabry C; Zietz C; Baumann A; Ehall R; Bader R Knee Surg Sports Traumatol Arthrosc; 2018 Sep; 26(9):2630-2639. PubMed ID: 28528349 [TBL] [Abstract][Full Text] [Related]
13. Use of Ion Beam Enhanced Deposition (IBED) Titanium Nitride for Knee Arthroplasty Implants. Alexander JS; Hurst JM; Morris MJ; Lombardi AV; Berend KR; Crawford DA Surg Technol Int; 2023 Sep; 42():239-243. PubMed ID: 36602186 [TBL] [Abstract][Full Text] [Related]
14. Titanium-Nitride Coating of Orthopaedic Implants: A Review of the Literature. van Hove RP; Sierevelt IN; van Royen BJ; Nolte PA Biomed Res Int; 2015; 2015():485975. PubMed ID: 26583113 [TBL] [Abstract][Full Text] [Related]
15. Effect of deep rolling on subsurface conditions of CoCr28Mo6 wrought alloy to improve the wear resistance of endoprostheses. Herbster M; Harnisch K; Haberland E; Kriegel P; Döbberthin C; Heyn A; Döring J; Lohmann CH; Bertrand J; Halle T J Mech Behav Biomed Mater; 2021 Jun; 118():104398. PubMed ID: 33667927 [TBL] [Abstract][Full Text] [Related]
16. Influence of polyetheretherketone coatings on the Ti-13Nb-13Zr titanium alloy's bio-tribological properties and corrosion resistance. Sak A; Moskalewicz T; Zimowski S; Cieniek Ł; Dubiel B; Radziszewska A; Kot M; Łukaszczyk A Mater Sci Eng C Mater Biol Appl; 2016 Jun; 63():52-61. PubMed ID: 27040195 [TBL] [Abstract][Full Text] [Related]
17. Biocompatibility and mechanical properties of diamond-like coatings on cobalt-chromium-molybdenum steel and titanium-aluminum-vanadium biomedical alloys. Hinüber C; Kleemann C; Friederichs RJ; Haubold L; Scheibe HJ; Schuelke T; Boehlert C; Baumann MJ J Biomed Mater Res A; 2010 Nov; 95(2):388-400. PubMed ID: 20648536 [TBL] [Abstract][Full Text] [Related]