These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
175 related articles for article (PubMed ID: 32873040)
1. Coherence-based quantification of acoustic clutter sources in medical ultrasound. Long J; Long W; Bottenus N; Trahey G J Acoust Soc Am; 2020 Aug; 148(2):1051. PubMed ID: 32873040 [TBL] [Abstract][Full Text] [Related]
2. Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging. Vienneau EP; Ozgun KA; Byram BC IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Apr; 69(4):1337-1352. PubMed ID: 35175919 [TBL] [Abstract][Full Text] [Related]
3. Incoherent Clutter Suppression Using Lag-One Coherence. Long W; Bottenus N; Trahey GE IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Aug; 67(8):1544-1557. PubMed ID: 32142428 [TBL] [Abstract][Full Text] [Related]
4. Iterative Model-Based Beamforming for High Dynamic Range Applications. Schlunk S; Dei K; Byram B IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Mar; 68(3):482-493. PubMed ID: 32746227 [TBL] [Abstract][Full Text] [Related]
5. Reverberation Clutter Suppression Using 2-D Spatial Coherence Analysis. Ahmed R; Bottenus N; Long J; Trahey GE IEEE Trans Ultrason Ferroelectr Freq Control; 2022 Jan; 69(1):84-97. PubMed ID: 34437060 [TBL] [Abstract][Full Text] [Related]
6. A Spatial Coherence Beamformer Design for Power Doppler Imaging. Ozgun K; Tierney J; Byram B IEEE Trans Med Imaging; 2020 May; 39(5):1558-1570. PubMed ID: 31725374 [TBL] [Abstract][Full Text] [Related]
7. Simultaneous Noise Suppression and Incoherent Artifact Reduction in Ultrafast Ultrasound Vascular Imaging. Huang C; Song P; Trzasko JD; Gong P; Lok UW; Tang S; Manduca A; Chen S IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Jun; 68(6):2075-2085. PubMed ID: 33513103 [TBL] [Abstract][Full Text] [Related]
8. Dual apodization with cross-correlation in the presence of phase aberration and noise. Yen JT; Seo CH Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2209-12. PubMed ID: 19163137 [TBL] [Abstract][Full Text] [Related]
9. Dual apodization with cross-correlation in the presence of phase aberration and noise. Yen JT; Seo CH Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():2542-5. PubMed ID: 19163221 [TBL] [Abstract][Full Text] [Related]
15. In vivo application of short-lag spatial coherence and harmonic spatial coherence imaging in fetal ultrasound. Kakkad V; Dahl J; Ellestad S; Trahey G Ultrason Imaging; 2015 Apr; 37(2):101-16. PubMed ID: 25116292 [TBL] [Abstract][Full Text] [Related]
16. Spatial coherence in human tissue: implications for imaging and measurement. Pinton G; Trahey G; Dahl J IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Dec; 61(12):1976-87. PubMed ID: 25474774 [TBL] [Abstract][Full Text] [Related]
17. Ultrafast Power Doppler Imaging Using Frame-Multiply-and-Sum-Based Nonlinear Compounding. Kang J; Go D; Song I; Yoo Y IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Mar; 68(3):453-464. PubMed ID: 32746224 [TBL] [Abstract][Full Text] [Related]
18. Synergistic enhancements of ultrasound image contrast with a combination of phase aberration correction and dual apodization with cross-correlation. Shin J; Yen J IEEE Trans Ultrason Ferroelectr Freq Control; 2012 Sep; 59(9):2089-101. PubMed ID: 23007784 [TBL] [Abstract][Full Text] [Related]
19. Evaluating the robustness of dual apodization with cross-correlation. Seo CH; Yen JT IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Feb; 56(2):291-303. PubMed ID: 19251516 [TBL] [Abstract][Full Text] [Related]
20. Spatial Prediction Filtering of Acoustic Clutter and Random Noise in Medical Ultrasound Imaging. Shin J; Huang L IEEE Trans Med Imaging; 2017 Feb; 36(2):396-406. PubMed ID: 27654323 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]