These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Influence of implant shape, surface morphology, surgical technique and bone quality on the primary stability of dental implants. Elias CN; Rocha FA; Nascimento AL; Coelho PG J Mech Behav Biomed Mater; 2012 Dec; 16():169-80. PubMed ID: 23182386 [TBL] [Abstract][Full Text] [Related]
4. Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis. Falco A; Berardini M; Trisi P Int J Oral Maxillofac Implants; 2018; 33(4):824-830. PubMed ID: 30024998 [TBL] [Abstract][Full Text] [Related]
5. Effects of dental implant diameter and tapered body design on stress distribution in rigid polyurethane foam during insertion. Yang B; Landa AI; Heuberger P; Ploeg HL Med Eng Phys; 2024 Jul; 129():104181. PubMed ID: 38906568 [TBL] [Abstract][Full Text] [Related]
6. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study. Tabassum A; Meijer GJ; Wolke JG; Jansen JA Clin Oral Implants Res; 2010 Feb; 21(2):213-20. PubMed ID: 20070754 [TBL] [Abstract][Full Text] [Related]
7. The impact of a modified cutting flute implant design on osseointegration. Jimbo R; Tovar N; Marin C; Teixeira HS; Anchieta RB; Silveira LM; Janal MN; Shibli JA; Coelho PG Int J Oral Maxillofac Surg; 2014 Jul; 43(7):883-8. PubMed ID: 24583140 [TBL] [Abstract][Full Text] [Related]
8. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study. Tabassum A; Meijer GJ; Wolke JG; Jansen JA Clin Oral Implants Res; 2009 Apr; 20(4):327-32. PubMed ID: 19298286 [TBL] [Abstract][Full Text] [Related]
9. The effect of implant design on insertion torque and immediate micromotion. Freitas AC; Bonfante EA; Giro G; Janal MN; Coelho PG Clin Oral Implants Res; 2012 Jan; 23(1):113-8. PubMed ID: 21426405 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of the effect of self-cutting and nonself-cutting thread designed implant with different thread depth on variable insertion torques: An histomorphometric analysis in rabbits. Muktadar AK; Gangaiah M; Chrcanovic BR; Chowdhary R Clin Implant Dent Relat Res; 2018 Aug; 20(4):507-514. PubMed ID: 29659124 [TBL] [Abstract][Full Text] [Related]
11. Insertion Torque of Variable-Thread Tapered Implants in the Posterior Maxilla: A Clinical Study. Abi-Aad HL; Daher FI; Baba NZ; Cordioli G; Majzoub ZAK J Prosthodont; 2019 Feb; 28(2):e788-e794. PubMed ID: 30178903 [TBL] [Abstract][Full Text] [Related]
12. Cortical Thickness, Bone Density, and the Insertion Torque/Depth Integral: A Study Using Polyurethane Foam Blocks. Di Stefano DA; Piattelli A; Iezzi G; Orlando F; Arosio P Int J Oral Maxillofac Implants; 2021; 36(3):423-431. PubMed ID: 34115054 [TBL] [Abstract][Full Text] [Related]
13. The effects of superficial roughness and design on the primary stability of dental implants. Dos Santos MV; Elias CN; Cavalcanti Lima JH Clin Implant Dent Relat Res; 2011 Sep; 13(3):215-23. PubMed ID: 19744197 [TBL] [Abstract][Full Text] [Related]
14. [Torque of endosseous dental screw type implants]. Schmid MR; Schiel HJ; Lambrecht JT Schweiz Monatsschr Zahnmed; 2002; 112(8):804-13. PubMed ID: 12244931 [TBL] [Abstract][Full Text] [Related]
15. Biomechanical comparison of compact versus standard flute drill bits, and interlocking versus buttress thread self-tapping cortical bone screws in cadaveric equine third metacarpal condyle. Pye JL; Garcia TC; Kapatkin AS; Samol MA; Stover S Vet Surg; 2023 Nov; 52(8):1128-1139. PubMed ID: 37302003 [TBL] [Abstract][Full Text] [Related]
16. A comparison of screw insertion torque and pullout strength. Ricci WM; Tornetta P; Petteys T; Gerlach D; Cartner J; Walker Z; Russell TA J Orthop Trauma; 2010 Jun; 24(6):374-8. PubMed ID: 20502221 [TBL] [Abstract][Full Text] [Related]
17. Integrative Performance Analysis of a Novel Bone Level Tapered Implant. Dard M; Kuehne S; Obrecht M; Grandin M; Helfenstein J; Pippenger BE Adv Dent Res; 2016 Mar; 28(1):28-33. PubMed ID: 26927485 [TBL] [Abstract][Full Text] [Related]
18. Influences of screw design features on initial stability in immediate implant placement and restoration. Hsieh MC; Huang CH; Hsu ML Clin Biomech (Bristol, Avon); 2021 Oct; 89():105453. PubMed ID: 34438334 [TBL] [Abstract][Full Text] [Related]
19. Effect of cutting flute design features on primary stability of immediate implant placement and restoration: a dynamic experimental analysis. Hsieh MC; Huang CH; Hsu ML Med Biol Eng Comput; 2023 Feb; 61(2):475-484. PubMed ID: 36515776 [TBL] [Abstract][Full Text] [Related]
20. Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology. Guzaitis KL; Knoernschild KL; Viana MA J Prosthet Dent; 2011 Sep; 106(3):159-69. PubMed ID: 21889002 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]