These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 32889330)

  • 1. Dual Tack Mesh Fixation System on a Cadaveric Porcine Model-Creation of a Mesh Fixation System for Hernia Treatment and Prevention.
    Elfanagely O; Othman S; Sanchez JA; Rios-Diaz A; Mellia JA; Fischer JP
    J Surg Res; 2021 Jan; 257():317-325. PubMed ID: 32889330
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Parameters of Mesh Reinforcement and Analysis of a Novel Device for Incisional Hernia Prevention.
    Messa CA; Sanchez J; Kozak GM; Shetye S; Rodriguez A; Fischer JP
    J Surg Res; 2021 Feb; 258():153-161. PubMed ID: 33010561
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical evaluation of fixation properties of fibrin glue for ventral incisional hernia repair.
    Stoikes N; Sharpe J; Tasneem H; Roan E; Paulus E; Powell B; Webb D; Handorf C; Eckstein E; Fabian T; Voeller G
    Hernia; 2015 Feb; 19(1):161-6. PubMed ID: 24062143
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Onlay with Adhesive Use Compared with Sublay Mesh Placement in Ventral Hernia Repair: Was Chevrel Right? An Americas Hernia Society Quality Collaborative Analysis.
    Haskins IN; Voeller GR; Stoikes NF; Webb DL; Chandler RG; Phillips S; Poulose BK; Rosen MJ
    J Am Coll Surg; 2017 May; 224(5):962-970. PubMed ID: 28161483
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mesh fixation using novel bio-adhesive coating compared to tack fixation for IPOM hernia repair: in vivo evaluation in a porcine model.
    Ben Yehuda A; Nyska A; Szold A
    Surg Endosc; 2019 Jul; 33(7):2364-2375. PubMed ID: 31069501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of Mesh Fixation Techniques in Elective Laparoscopic Repair of Incisional Hernia-ReliaTack™ v ProTack™ (TACKoMesh) - A double-blind randomised controlled trial.
    Sheen AJ; Pilkington JJ; Baltatzis M; Tyurkylmaz A; Stathakis P; Jamdar S; Siriwardena AK
    BMC Surg; 2018 Jul; 18(1):46. PubMed ID: 29996841
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Tensile strength testing for resorbable mesh fixation systems in laparoscopic ventral hernia repair.
    Reynvoet E; Berrevoet F; De Somer F; Vercauteren G; Vanoverbeke I; Chiers K; Troisi R
    Surg Endosc; 2012 Sep; 26(9):2513-20. PubMed ID: 22476828
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of mesh fixation devices for laparoscopic ventral hernia repair: an experimental study on human anatomic specimens.
    Chan YW; Sow Z; Lukic D; Monschein M; Calek E; Pretterklieber M; Hollinsky C
    Surg Endosc; 2018 Jul; 32(7):3158-3163. PubMed ID: 29340814
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reversibility of abdominal wall atrophy and fibrosis after primary or mesh herniorrhaphy.
    Culbertson EJ; Xing L; Wen Y; Franz MG
    Ann Surg; 2013 Jan; 257(1):142-9. PubMed ID: 22801088
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair.
    Ibrahim MM; Poveromo LP; Glisson RR; Cornejo A; Farjat AE; Gall K; Levinson H
    J Biomech; 2018 Apr; 71():43-51. PubMed ID: 29426630
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A meta-analysis comparing tacker mesh fixation with suture mesh fixation in laparoscopic incisional and ventral hernia repair.
    Sajid MS; Parampalli U; McFall MR
    Hernia; 2013 Apr; 17(2):159-66. PubMed ID: 23138861
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mesh fixation with a barbed anchor suture results in significantly less strangulation of the abdominal wall.
    Lyons C; Joseph R; Salas N; Reardon PR; Bass BL; Dunkin BJ
    Surg Endosc; 2012 May; 26(5):1254-7. PubMed ID: 22083327
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interposition of the omentum and/or the peritoneum in the emergency repair of large ventral hernias with polypropylene mesh.
    Sorour MA
    Int J Surg; 2014; 12(6):578-86. PubMed ID: 24793234
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparisons of Onlay versus Sublay Mesh Fixation Technique in Ventral Abdominal Wall Incisional Hernia Repair.
    Ahmed M; Mehboob M
    J Coll Physicians Surg Pak; 2019 Sep; 29(9):819-822. PubMed ID: 31455474
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preliminary report of a sutureless onlay technique for incisional hernia repair using fibrin glue alone for mesh fixation.
    Stoikes N; Webb D; Powell B; Voeller G
    Am Surg; 2013 Nov; 79(11):1177-80. PubMed ID: 24165253
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Adding sutures to tack fixation of mesh does not lower the re-operation rate after laparoscopic ventral hernia repair: a nationwide cohort study.
    Baker JJ; Öberg S; Andresen K; Helgstrand F; Rosenberg J
    Langenbecks Arch Surg; 2018 Jun; 403(4):521-527. PubMed ID: 29785453
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Suture, synthetic, or biologic in contaminated ventral hernia repair.
    Bondre IL; Holihan JL; Askenasy EP; Greenberg JA; Keith JN; Martindale RG; Roth JS; Liang MK;
    J Surg Res; 2016 Feb; 200(2):488-94. PubMed ID: 26424112
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Decreased re-operation rate for recurrence after defect closure in laparoscopic ventral hernia repair with a permanent tack fixated mesh: a nationwide cohort study.
    Baker JJ; Öberg S; Andresen K; Rosenberg J
    Hernia; 2018 Aug; 22(4):577-584. PubMed ID: 29748724
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A double blind randomized controlled trial comparing primary suture closure with mesh augmented closure to reduce incisional hernia incidence.
    Nieuwenhuizen J; Eker HH; Timmermans L; Hop WC; Kleinrensink GJ; Jeekel J; Lange JF;
    BMC Surg; 2013 Oct; 13():48. PubMed ID: 24499111
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Randomized clinical trial of mesh fixation with "double crown" versus "sutures and tackers" in laparoscopic ventral hernia repair.
    Muysoms F; Vander Mijnsbrugge G; Pletinckx P; Boldo E; Jacobs I; Michiels M; Ceulemans R
    Hernia; 2013 Oct; 17(5):603-12. PubMed ID: 23546864
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.