These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 32890640)

  • 1. The Effect of Mechanical Properties of Synthetic Prostheses Made by Electrospinning on the Results of Experimental Implantation in the Infrarenal Abdominal Aorta.
    Tsygankov YM; Zhorzholiani ST; Khugaev GA; Tevosov DR; Shepelev AD; Krasheninnikov SV; Gorodkov AY; Bockeria LA
    Ann Vasc Surg; 2021 Jan; 70():506-516. PubMed ID: 32890640
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental noninferiority trial of synthetic small-caliber biodegradable versus stable vascular grafts.
    Mugnai D; Tille JC; Mrówczyński W; de Valence S; Montet X; Möller M; Walpoth BH
    J Thorac Cardiovasc Surg; 2013 Aug; 146(2):400-7.e1. PubMed ID: 23098749
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The Effect of Mechanical Compatibility and of Thrombogenicity on the Ingrowth of a New Synthetic Vascular Prosthesis (Experimental Study).
    Tsygankov YM; Sergeev AA; Zhorzholiani ST; Shepelev AD; Krasheninnikov SV; Tenchurin TK; Agafonov AV; Gorodkov AY; Bockeria LA
    Dokl Biochem Biophys; 2021 Sep; 500(1):317-320. PubMed ID: 34697735
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An Experimental Evaluation of Device/Arterial Wall Compliance Mismatch for Four Stent-Graft Devices and a Multi-layer Flow Modulator Device for the Treatment of Abdominal Aortic Aneurysms.
    Morris L; Stefanov F; Hynes N; Diethrich EB; Sultan S
    Eur J Vasc Endovasc Surg; 2016 Jan; 51(1):44-55. PubMed ID: 26363972
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of γ-Radiation on Mechanical Stability to Cyclic Loads Tubular Elastic Matrix of the Aorta.
    Gorodkov AY; Tsygankov YM; Shepelev AD; Krasheninnikov SV; Zhorzholiani ST; Agafonov AV; Mamagulashvili VG; Savinov DV; Tenchurin TK; Chvalun SN
    J Funct Biomater; 2022 Oct; 13(4):. PubMed ID: 36278661
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of remodeling process in small-diameter cell-free tissue-engineered arterial graft.
    Tara S; Kurobe H; Maxfield MW; Rocco KA; Yi T; Naito Y; Breuer CK; Shinoka T
    J Vasc Surg; 2015 Sep; 62(3):734-43. PubMed ID: 24745941
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of implantation site on outcome of tissue-engineered vascular grafts.
    Sologashvili T; Saat SA; Tille JC; De Valence S; Mugnai D; Giliberto JP; Dillon J; Yakub A; Dimon Z; Gurny R; Walpoth BH; Moeller M
    Eur J Pharm Biopharm; 2019 Jun; 139():272-278. PubMed ID: 31004790
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical development and initial animal experience with a novel, uncovered, self-expanding, highly flexible aortic stent with improved side branch access.
    Eggebrecht H; Kahlert P; Kaiser GM; McDougall I; Sarrat-Cave Z; Herrmann RA; Erbel R
    J Endovasc Ther; 2009 Oct; 16(5):539-45. PubMed ID: 19842725
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modification of the descending thoracic aortic anastomotic site using biodegradable felt: study in a canine model with or without basic fibroblast growth factor.
    Fujiwara H; Saiki Y; Sato M; Sakamoto N; Ohashi T; Sato M; Tabata Y; Tabayashi K
    J Vasc Surg; 2010 Jan; 51(1):194-202. PubMed ID: 19914025
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Novel synthetic selectively degradable vascular prostheses: a preliminary implantation study.
    Izhar U; Schwalb H; Borman JB; Hellener GR; Hotoveli-Salomon A; Marom G; Stern T; Cohn D
    J Surg Res; 2001 Feb; 95(2):152-60. PubMed ID: 11162039
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fast-degrading bioresorbable arterial vascular graft with high cellular infiltration inhibits calcification of the graft.
    Sugiura T; Tara S; Nakayama H; Yi T; Lee YU; Shoji T; Breuer CK; Shinoka T
    J Vasc Surg; 2017 Jul; 66(1):243-250. PubMed ID: 27687327
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Towards compliant small-diameter vascular grafts: Predictive analytical model and experiments.
    Bouchet M; Gauthier M; Maire M; Ajji A; Lerouge S
    Mater Sci Eng C Mater Biol Appl; 2019 Jul; 100():715-723. PubMed ID: 30948109
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The inner prosthetic surface structure and re-endothelialization: an experimental study in the rat using two types of microvascular prostheses for aortic implantation.
    Hess F; Jerusalem C; Braun B; Grande P
    Microsurgery; 1986; 7(1):29-37. PubMed ID: 3702663
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Five types of polyurethane vascular grafts in dogs: the importance of structural design and material selection.
    Xie X; Eberhart A; Guidoin R; Marois Y; Douville Y; Zhang Z
    J Biomater Sci Polym Ed; 2010; 21(8-9):1239-64. PubMed ID: 20507718
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Long-term patency of small-diameter vascular graft made from fibroin, a silk-based biodegradable material.
    Enomoto S; Sumi M; Kajimoto K; Nakazawa Y; Takahashi R; Takabayashi C; Asakura T; Sata M
    J Vasc Surg; 2010 Jan; 51(1):155-64. PubMed ID: 19954921
    [TBL] [Abstract][Full Text] [Related]  

  • 16. In Situ Blood Vessel Regeneration Using SP (Substance P) and SDF (Stromal Cell-Derived Factor)-1α Peptide Eluting Vascular Grafts.
    Shafiq M; Zhang Q; Zhi D; Wang K; Kong D; Kim DH; Kim SH
    Arterioscler Thromb Vasc Biol; 2018 Jul; 38(7):e117-e134. PubMed ID: 29853570
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of the deployment and healing of thin-walled expanded PTFE stented grafts and covered stents.
    White R; Kopchok G; Zalewski M; Ayres B; Wilson E; de Virgilio C; Donayre C
    Ann Vasc Surg; 1996 Jul; 10(4):336-46. PubMed ID: 8879388
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Abdominal aortic healing associated with a thin-walled Dacron-covered endovascular graft in a canine model.
    Dal Ponte DB; Berman SS; Patula V; Kleinert L; Williams SK
    J Endovasc Ther; 2002 Jun; 9(3):333-43. PubMed ID: 12096948
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bioengineered vascular graft grown in the mouse peritoneal cavity.
    Song L; Wang L; Shah PK; Chaux A; Sharifi BG
    J Vasc Surg; 2010 Oct; 52(4):994-1002, 1002.e1-2. PubMed ID: 20692791
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Remodeling of structurally reinforced (TPU+PCL/PCL)-Hep electrospun small-diameter bilayer vascular grafts interposed in rat abdominal aortas.
    Fang Z; Xing Y; Wang H; Geng X; Ye L; Zhang AY; Gu Y; Feng ZG
    Biomater Sci; 2022 Jul; 10(15):4257-4270. PubMed ID: 35766246
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.