These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

309 related articles for article (PubMed ID: 32891225)

  • 41. Implementation of a systematic culturing program to monitor the efficacy of endoscope reprocessing: outcomes and costs.
    Ma GK; Pegues DA; Kochman ML; Alby K; Fishman NO; Saunders M; Grous C; Dempsey DT; Ginsberg GG
    Gastrointest Endosc; 2018 Jan; 87(1):104-109.e3. PubMed ID: 28499830
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Procedures in endoscope reprocessing and monitoring: an Italian survey.
    Cristina ML; Valeriani F; Casini B; Agodi A; D'Errico MM; Gianfranceschi G; Laganà P; Liguori G; Liguori R; Mucci N; Mura I; Pasquarella C; Piana A; Sotgiu G; Privitera G; Protano C; Quattrocchi A; Ripabelli G; Rossini A; Scaramucci E; Spagnolo AM; Tamburro M; Tardivo S; Veronesi L; Vitali M; Romano Spica V
    Ann Ig; 2018; 30(5 Supple 2):45-63. PubMed ID: 30374511
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Independent root-cause analysis of contributing factors, including dismantling of 2 duodenoscopes, to investigate an outbreak of multidrug-resistant Klebsiella pneumoniae.
    Rauwers AW; Troelstra A; Fluit AC; Wissink C; Loeve AJ; Vleggaar FP; Bruno MJ; Vos MC; Bode LG; Monkelbaan JF
    Gastrointest Endosc; 2019 Nov; 90(5):793-804. PubMed ID: 31102643
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Prion disease and recommended procedures for flexible endoscope reprocessing - a review of policies worldwide and proposal for a simplified approach.
    Kampf G; Jung M; Suchomel M; Saliou P; Griffiths H; Vos MC
    J Hosp Infect; 2020 Jan; 104(1):92-110. PubMed ID: 31408691
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Enhanced manual cleaning efficacy of duodenoscope in endoscopy units: Results of a multicenter comprehensive quality control program.
    Chang WK; Liu TC; Liu TL; Peng CL; Wang HP
    Am J Infect Control; 2019 Oct; 47(10):1233-1239. PubMed ID: 31126624
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Randomized Comparison of 3 High-Level Disinfection and Sterilization Procedures for Duodenoscopes.
    Snyder GM; Wright SB; Smithey A; Mizrahi M; Sheppard M; Hirsch EB; Chuttani R; Heroux R; Yassa DS; Olafsdottir LB; Davis RB; Anastasiou J; Bapat V; Bidari K; Pleskow DK; Leffler D; Lane B; Chen A; Gold HS; Bartley A; King AD; Sawhney MS
    Gastroenterology; 2017 Oct; 153(4):1018-1025. PubMed ID: 28711629
    [TBL] [Abstract][Full Text] [Related]  

  • 47. An update on gastrointestinal endoscopy-associated infections and their contributing factors.
    McCafferty CE; Aghajani MJ; Abi-Hanna D; Gosbell IB; Jensen SO
    Ann Clin Microbiol Antimicrob; 2018 Oct; 17(1):36. PubMed ID: 30314500
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Reducing infection risk in colonoscopy.
    Greenwald D
    Gastrointest Endosc Clin N Am; 2010 Oct; 20(4):603-14. PubMed ID: 20889066
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Endoscopic retrograde cholangiopancreatography and endoscopic ultrasound endoscope reprocessing: Variables impacting contamination risk.
    Ayres AM; Wozniak J; O'Neil J; Stewart K; Leger JS; Pasculle AW; Lewis C; McGrath K; Slivka A; Snyder GM
    Infect Control Hosp Epidemiol; 2023 Sep; 44(9):1485-1489. PubMed ID: 36645014
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Surveillance of guideline practices for duodenoscope and linear echoendoscope reprocessing in a large healthcare system.
    Brandabur JJ; Leggett JE; Wang L; Bartles RL; Baxter L; Diaz GA; Grunkemeier GL; Hove S; Oethinger M
    Gastrointest Endosc; 2016 Sep; 84(3):392-399.e3. PubMed ID: 27032883
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Performance characteristics and optimal cut-off value of triple adenylate nucleotides test versus adenosine triphosphate test as point-of-care testing for predicting inadequacy of duodenoscope reprocessing.
    Ridtitid W; Pakvisal P; Chatsuwan T; Kerr SJ; Piyachaturawat P; Luangsukrerk T; Kongkam P; Rerknimitr R
    J Hosp Infect; 2020 Oct; 106(2):348-356. PubMed ID: 32768608
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Outbreaks of carbapenem-resistant Enterobacteriaceae infections associated with duodenoscopes: What can we do to prevent infections?
    Rutala WA; Weber DJ
    Am J Infect Control; 2016 May; 44(5 Suppl):e47-51. PubMed ID: 27131135
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Duodenoscope-Associated Infections: Update on an Emerging Problem.
    Rahman MR; Perisetti A; Coman R; Bansal P; Chhabra R; Goyal H
    Dig Dis Sci; 2019 Jun; 64(6):1409-1418. PubMed ID: 30569333
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Elevating the standard of endoscope processing: Terminal sterilization of duodenoscopes using a hydrogen peroxide-ozone sterilizer.
    Molloy-Simard V; Lemyre JL; Martel K; Catalone BJ
    Am J Infect Control; 2019 Mar; 47(3):243-250. PubMed ID: 30442443
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Reprocessing of flexible endoscopes.
    Leung JW
    J Gastroenterol Hepatol; 2000 Oct; 15 Suppl():G73-7. PubMed ID: 11100997
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Adequacy of Duodenoscope Reprocessing Methods as Reported by Infectious Disease Physicians.
    Beekmann SE; Palmore TN; Polgreen PM; Bennett JE
    Infect Control Hosp Epidemiol; 2016 Feb; 37(2):226-8. PubMed ID: 26503302
    [No Abstract]   [Full Text] [Related]  

  • 57. Liquid disinfecting and sterilization reprocessors used for flexible endoscopes.
    Health Devices; 1994 Jun; 23(6):212-53. PubMed ID: 7852072
    [TBL] [Abstract][Full Text] [Related]  

  • 58. APSIC guidelines for disinfection and sterilization of instruments in health care facilities.
    Ling ML; Ching P; Widitaputra A; Stewart A; Sirijindadirat N; Thu LTA
    Antimicrob Resist Infect Control; 2018; 7():25. PubMed ID: 29468053
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Duodenoscope reprocessing surveillance with adenosine triphosphate testing and terminal cultures: a clinical pilot study.
    Visrodia K; Hanada Y; Pennington KM; Tosh PK; Topazian MD; Petersen BT
    Gastrointest Endosc; 2017 Jul; 86(1):180-186. PubMed ID: 28396277
    [TBL] [Abstract][Full Text] [Related]  

  • 60. A review of reprocessing techniques of flexible nasopharyngoscopes.
    Collins WO
    Otolaryngol Head Neck Surg; 2009 Sep; 141(3):307-10. PubMed ID: 19716004
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 16.