BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 32892606)

  • 21. Clinical Study of 3D Imaging and 3D Printing Technique for Patient-Specific Instrumentation in Total Knee Arthroplasty.
    Qiu B; Liu F; Tang B; Deng B; Liu F; Zhu W; Zhen D; Xue M; Zhang M
    J Knee Surg; 2017 Oct; 30(8):822-828. PubMed ID: 28122388
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Patient-Specific Instrumentation Does Not Affect Rotational Alignment of the Femoral Component and Perioperative Blood Loss in Total Knee Arthroplasty: A Prospective, Randomized, Controlled Trial.
    Randelli PS; Menon A; Pasqualotto S; Zanini B; Compagnoni R; Cucchi D
    J Arthroplasty; 2019 Jul; 34(7):1374-1381.e1. PubMed ID: 30979672
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Use of patient-specific cutting blocks reduces blood loss after total knee arthroplasty.
    León VJ; Lengua MA; Calvo V; Lisón AJ
    Eur J Orthop Surg Traumatol; 2017 Feb; 27(2):273-277. PubMed ID: 27999958
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of Functional Outcomes of Computer-Assisted vs Conventional Total Knee Arthroplasty: A Systematic Review and Meta-Analysis of High-Quality, Prospective Studies.
    Panjwani TR; Mullaji A; Doshi K; Thakur H
    J Arthroplasty; 2019 Mar; 34(3):586-593. PubMed ID: 30611520
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A comparative analysis of the role of Tranexamic acid as an independent variable in reducing intraoperative blood loss in patients undergoing conventional total knee arthroplasty versus computer-assisted total knee arthroplasty.
    Eachempati KK; Gurava Reddy AV; Apsingi S; Sankineani SR; Shaheed J; Dannana C
    Musculoskelet Surg; 2017 Dec; 101(3):255-259. PubMed ID: 28470576
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of total knee arthroplasty performed with and without computer navigation: a bilateral total knee arthroplasty study.
    Johnson DR; Dennis DA; Kindsfater KA; Kim RH
    J Arthroplasty; 2013 Mar; 28(3):455-8. PubMed ID: 23164836
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Effect of total knee arthroplasty under computer navigation on intraoperative blood loss and joint function recovery].
    Yu QB; E ZK; Xin HW; Zhang YS; Lin YZ
    Zhongguo Gu Shang; 2020 Jan; 33(1):15-20. PubMed ID: 32115919
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Computer-Assisted Total Knee Arthroplasty vs. Conventional Total Knee Arthroplasty: Post-Operative Ankle Radiographic Findings and Ankle Clinical Assessment.
    Chompoosang T; Khongphaophong M; Chunsiri P; Sripirom P
    J Med Assoc Thai; 2016 Feb; 99 Suppl 2():S168-74. PubMed ID: 27266232
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Total knee arthroplasty in patients with Ranawat type-II valgus arthritic knee with a marked coronal femoral bowing deformity: comparison between computer-assisted surgery and intra-articular resection.
    Huang TW; Chuang PY; Lee CY; Lin SJ; Huang KC; Shen SH; Tsai YH; Lee MS; Hsu RW
    J Orthop Surg Res; 2016 Aug; 11(1):88. PubMed ID: 27488841
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Abnormal rate of intraoperative and postoperative implant positioning outliers using "MRI-based patient-specific" compared to "computer assisted" instrumentation in total knee replacement.
    Ollivier M; Tribot-Laspiere Q; Amzallag J; Boisrenoult P; Pujol N; Beaufils P
    Knee Surg Sports Traumatol Arthrosc; 2016 Nov; 24(11):3441-3447. PubMed ID: 25994474
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted surgery in total knee arthroplasty.
    Laende EK; Richardson CG; Dunbar MJ
    Bone Joint J; 2019 Aug; 101-B(8):929-940. PubMed ID: 31362561
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Modern abbreviated computer navigation of the femur reduces blood loss in total knee arthroplasty.
    Licini DJ; Meneghini RM
    J Arthroplasty; 2015 Oct; 30(10):1729-32. PubMed ID: 25971778
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A Comparison of the Medium-Term Results of Total Knee Arthroplasty Using Computer-Assisted and Conventional Techniques to Treat Patients With Extraarticular Femoral Deformities.
    Bae DK; Song SJ; Park CH; Ko YW; Lee H
    J Arthroplasty; 2017 Jan; 32(1):71-78. PubMed ID: 27460297
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Total knee arthroplasty with computer-assisted navigation more closely replicates normal knee biomechanics than conventional surgery.
    McClelland JA; Webster KE; Ramteke AA; Feller JA
    Knee; 2017 Jun; 24(3):651-656. PubMed ID: 28233605
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Early clinical effects of total knee arthroplasty with kinematic alignment assisted by patient-specific instrumentation].
    Wang ZW; Wen L; Yu Y; Ma DS; Zhou L; Zhang B; Ren SX; Lin Y; Pan J; Qu TB
    Zhonghua Wai Ke Za Zhi; 2020 Jun; 58(6):457-463. PubMed ID: 32498486
    [No Abstract]   [Full Text] [Related]  

  • 36. Similar outcomes in computer-assisted and conventional total knee arthroplasty: ten-year results of a prospective randomized study.
    Beyer F; Pape A; Lützner C; Kirschner S; Lützner J
    BMC Musculoskelet Disord; 2021 Aug; 22(1):707. PubMed ID: 34407776
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Can a Single-Use and Patient-Specific Instrumentation Be Reliably Used in Primary Total Knee Arthroplasty? A Multicenter Controlled Study.
    Abane L; Zaoui A; Anract P; Lefevre N; Herman S; Hamadouche M
    J Arthroplasty; 2018 Jul; 33(7):2111-2118. PubMed ID: 29576488
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Thirty-Day Complications of Conventional and Computer-Assisted Total Knee and Total Hip Arthroplasty: Analysis of 103,855 Patients in the American College of Surgeons National Surgical Quality Improvement Program Database.
    Aoude AA; Aldebeyan SA; Nooh A; Weber MH; Tanzer M
    J Arthroplasty; 2016 Aug; 31(8):1674-9. PubMed ID: 26923496
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A comparison of alignment using patient specific guides, computer navigation and conventional instrumentation in total knee arthroplasty.
    MacDessi SJ; Jang B; Harris IA; Wheatley E; Bryant C; Chen DB
    Knee; 2014 Mar; 21(2):406-9. PubMed ID: 24378337
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Patient-specific instrumentation improved axial alignment of the femoral component, operative time and perioperative blood loss after total knee arthroplasty.
    Gong S; Xu W; Wang R; Wang Z; Wang B; Han L; Chen G
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1083-1095. PubMed ID: 30377714
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.