These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

581 related articles for article (PubMed ID: 32912279)

  • 21. [Comparison of effectiveness of long and short proximal femoral nail anti-rotation in treatment of type A2.3 intertrochanteric fracture of femur].
    Yue M; Yang D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2024 Jun; 38(6):703-709. PubMed ID: 38918191
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures.
    Nherera L; Trueman P; Horner A; Watson T; Johnstone AJ
    J Orthop Surg Res; 2018 Mar; 13(1):46. PubMed ID: 29499715
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The visible and hidden blood loss of Asia proximal femoral nail anti-rotation and dynamic hip screw in the treatment of intertrochanteric fractures of elderly high- risk patients: a retrospective comparative study with a minimum 3 years of follow-up.
    Yu W; Zhang X; Wu R; Zhu X; Hu J; Xu Y; Yi J; Liu Y
    BMC Musculoskelet Disord; 2016 Jul; 17():269. PubMed ID: 27401011
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Unstable pertrochanteric femur fractures. Failure rate, lag screw sliding and outcome with extra- and intramedullary devices (PCCP, DHS and PFN)].
    Knobe M; Münker R; Sellei RM; Schmidt-Rohlfing B; Erli HJ; Strobl CS; Niethard FU
    Z Orthop Unfall; 2009; 147(3):306-13. PubMed ID: 19551581
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Conversion to total hip arthroplasty after failed proximal femoral nail antirotations or dynamic hip screw fixations for stable intertrochanteric femur fractures: a retrospective study with a minimum follow-up of 3 years.
    Zeng X; Zhan K; Zhang L; Zeng D; Yu W; Zhang X; Zhao M
    BMC Musculoskelet Disord; 2017 Jan; 18(1):38. PubMed ID: 28122548
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Antirotation proximal femoral nail versus dynamic hip screw for intertrochanteric fractures: a meta-analysis of randomized controlled studies.
    Shen L; Zhang Y; Shen Y; Cui Z
    Orthop Traumatol Surg Res; 2013 Jun; 99(4):377-83. PubMed ID: 23707739
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Percutaneous compression plate versus dynamic hip screw for treatment of intertrochanteric hip fractures: A overview of systematic reviews and update meta-analysis of randomized controlled trials.
    Long H; Lin Z; Lu B; Zhao R; Sun B; Cheng L; Zhao S; Zhu Y
    Int J Surg; 2016 Sep; 33 Pt A():1-7. PubMed ID: 27398689
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Effectiveness comparison between proximal femoral nail anti-rotation and proximal femoral locking compression plate for intertrochanteric fracture in elderly patients combined with hemiplegia due to cerebral infarction].
    Wan Q; Zhang Q; Zhang Y; Liu Y; Yang X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2018 Nov; 32(11):1411-1416. PubMed ID: 30417616
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Comparative study of proximal femoral nail anti-rotation and dynamic hip screw in the unstable intertrochanteric fractures in the elderly].
    Wang W; Zhai S; Han XP; Cui Y
    Zhonghua Yi Xue Za Zhi; 2018 Jan; 98(5):357-361. PubMed ID: 29429246
    [No Abstract]   [Full Text] [Related]  

  • 30. Minimally invasive percutaneous compression plating versus dynamic hip screw for intertrochanteric fractures: a randomized control trial.
    Cheng Q; Huang W; Gong X; Wang C; Liang X; Hu N
    Chin J Traumatol; 2014; 17(5):249-55. PubMed ID: 25293893
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.
    Paulsson J; Stig JC; Olsson O
    BMC Musculoskelet Disord; 2017 Aug; 18(1):364. PubMed ID: 28836973
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Proximal femoral nail antirotation versus dynamic hip screw for intertrochanteric fracture in elders: a meta-analysis].
    Yuan X; Yao Q; Ni J; Peng L; Yu D
    Zhonghua Yi Xue Za Zhi; 2014 Mar; 94(11):836-9. PubMed ID: 24854751
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In reply to the letter to the editor regarding "Comparison of a twin interlocking derotation and compression screw cephalomedullary nail (InterTAN) with a single screw derotation cephalomedullary nail (proximal femoral nail antirotation): a systematic review and meta-analysis for intertrochanteric fractures".
    Nherera L; Trueman P; Horner A; Watson T; Johnstone AJ
    J Orthop Surg Res; 2022 Jul; 17(1):354. PubMed ID: 35842668
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [EFFECTIVENESS COMPARISON OF PROXIMAL FEMORAL NAIL ANTI-ROTATION IN SUPINE "SCISSORS" POSITION AND IN LITHOTOMY POSITION TO TREAT FEMORAL INTERTROCHANTERIC FRACTURES OF OLD PATIENTS].
    Du S; Yin F; Wei X; Song S; Gu S; Sun Z; Rui Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Feb; 30(2):152-5. PubMed ID: 27276805
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults.
    Parker MJ; Das A
    Cochrane Database Syst Rev; 2013 Feb; 2013(2):CD000339. PubMed ID: 23450528
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The percutaneous compression plate versus the dynamic hip screw for treatment of intertrochanteric hip fractures: a systematic review and meta-analysis of comparative studies.
    Ma J; Xing D; Ma X; Xu W; Wang J; Chen Y; Song D
    Orthop Traumatol Surg Res; 2012 Nov; 98(7):773-83. PubMed ID: 23044466
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures.
    Sahin S; Ertürer E; Oztürk I; Toker S; Seçkin F; Akman S
    Acta Orthop Traumatol Turc; 2010; 44(2):127-34. PubMed ID: 20676015
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Proximal femoral nails anti-rotation versus dynamic hip screws for treatment of stable intertrochanteric femur fractures: an outcome analyses with a minimum 4 years of follow-up.
    Yu W; Zhang X; Zhu X; Yu Z; Xu Y; Zha G; Hu J; Yi J; Liu Y
    BMC Musculoskelet Disord; 2016 May; 17():222. PubMed ID: 27209256
    [TBL] [Abstract][Full Text] [Related]  

  • 39. PFNA-II Internal Fixation Helps Hip Joint Recovery and Improves Quality of Life of Patients with Lateral-Wall Dangerous Type of Intertrochanteric Fracture.
    Mu W; Zhou J
    Biomed Res Int; 2021; 2021():5911868. PubMed ID: 34859101
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A Retrospective Study of 98 Elderly Patients with High-Risk Lateral Femoral Wall Intertrochanteric Hip Fractures to Compare Outcomes Following Surgery with Proximal Femoral Nail Antirotation (PFNA) Versus Dynamic Hip Screw (DHS).
    Tian Z; Chen J; Zhang Y; Shi L; Li W
    Med Sci Monit; 2022 Aug; 28():e936923. PubMed ID: 35974685
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 30.