These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
191 related articles for article (PubMed ID: 32929566)
1. Electrochemical immunosensor for determination of Staphylococcus aureus bacteria by IgY immobilized on glassy carbon electrode with electrodeposited gold nanoparticles. Roushani M; Rahmati Z; Golchin M; Lotfi Z; Nemati M Mikrochim Acta; 2020 Sep; 187(10):567. PubMed ID: 32929566 [TBL] [Abstract][Full Text] [Related]
2. Electrochemical immunosensor based on self-assembled gold nanorods for label-free and sensitive determination of Staphylococcus aureus. Han E; Li X; Zhang Y; Zhang M; Cai J; Zhang X Anal Biochem; 2020 Dec; 611():113982. PubMed ID: 33035460 [TBL] [Abstract][Full Text] [Related]
3. A label-free electrochemical impedance immunosensor based on AuNPs/PAMAM-MWCNT-Chi nanocomposite modified glassy carbon electrode for detection of Salmonella typhimurium in milk. Dong J; Zhao H; Xu M; Ma Q; Ai S Food Chem; 2013 Dec; 141(3):1980-6. PubMed ID: 23870918 [TBL] [Abstract][Full Text] [Related]
4. A disposable electrochemical immunosensor for carcinoembryonic antigen based on nano-Au/multi-walled carbon nanotubes-chitosans nanocomposite film modified glassy carbon electrode. Huang KJ; Niu DJ; Xie WZ; Wang W Anal Chim Acta; 2010 Feb; 659(1-2):102-8. PubMed ID: 20103110 [TBL] [Abstract][Full Text] [Related]
5. Design and fabrication of an electrochemical aptasensor using Au nanoparticles/carbon nanoparticles/cellulose nanofibers nanocomposite for rapid and sensitive detection of Staphylococcus aureus. Ranjbar S; Shahrokhian S Bioelectrochemistry; 2018 Oct; 123():70-76. PubMed ID: 29729642 [TBL] [Abstract][Full Text] [Related]
6. Investigate electrochemical immunosensor of cortisol based on gold nanoparticles/magnetic functionalized reduced graphene oxide. Sun B; Gou Y; Ma Y; Zheng X; Bai R; Ahmed Abdelmoaty AA; Hu F Biosens Bioelectron; 2017 Feb; 88():55-62. PubMed ID: 27499382 [TBL] [Abstract][Full Text] [Related]
7. Development of an electrochemical sensitive aptasensor based on a zeolite imidazolate framework-8 and gold nanoparticles for the determination of Staphylococcus aureus bacteria. Morsalpour H; Zare HR; Shekari Z; Mirbagheri M Anal Bioanal Chem; 2024 Feb; 416(5):1229-1238. PubMed ID: 38180496 [TBL] [Abstract][Full Text] [Related]
8. An affordable label-free ultrasensitive immunosensor based on gold nanoparticles deposited on glassy carbon electrode for the transferrin receptor detection. Ahmad A; Rabbani G; Zamzami MA; Hosawi S; Baothman OA; Altayeb H; Akhtar MSN; Ahmad V; Khan MV; Khan ME; Kim SH Int J Biol Macromol; 2024 Jul; 273(Pt 2):133083. PubMed ID: 38866289 [TBL] [Abstract][Full Text] [Related]
9. Fabrication of an affordable and sensitive corticosteroid-binding globulin immunosensor based on electrodeposited gold nanoparticles modified glassy carbon electrode. Rabbani G; Ahmad A; Zamzami MA; Baothman OA; Hosawi SA; Altayeb H; Shahid Nadeem M; Ahmad V Bioelectrochemistry; 2024 Jun; 157():108671. PubMed ID: 38401223 [TBL] [Abstract][Full Text] [Related]
10. Electrochemical immunosensor functionalized with nanobodies for the detection of the toxic microalgae Alexandrium minutum using glassy carbon electrode modified with gold nanoparticles. Oloketuyi S; Mazzega E; Zavašnik J; Pungjunun K; Kalcher K; de Marco A; Mehmeti E Biosens Bioelectron; 2020 Apr; 154():112052. PubMed ID: 32056958 [TBL] [Abstract][Full Text] [Related]
11. A novel label-free electrochemical immunesensor for ultrasensitive detection of LT toxin using prussian blue@gold nanoparticles composite as a signal amplification. Habibi MM; Mirhosseini SA; Sajjadi S; Keihan AH Bioelectrochemistry; 2021 Dec; 142():107887. PubMed ID: 34298495 [TBL] [Abstract][Full Text] [Related]
12. Electrochemical immunosensor for botulinum neurotoxin type-E using covalently ordered graphene nanosheets modified electrodes and gold nanoparticles-enzyme conjugate. Narayanan J; Sharma MK; Ponmariappan S; Sarita ; Shaik M; Upadhyay S Biosens Bioelectron; 2015 Jul; 69():249-56. PubMed ID: 25754919 [TBL] [Abstract][Full Text] [Related]
13. Ultrasensitive peptide-based multiplexed electrochemical biosensor for the simultaneous detection of Listeria monocytogenes and Staphylococcus aureus. Eissa S; Zourob M Mikrochim Acta; 2020 Aug; 187(9):486. PubMed ID: 32761391 [TBL] [Abstract][Full Text] [Related]
14. A sensitive sandwich-type immunosensor for the detection of galectin-3 based on N-GNRs-Fe-MOFs@AuNPs nanocomposites and a novel AuPt-methylene blue nanorod. Tang Z; He J; Chen J; Niu Y; Zhao Y; Zhang Y; Yu C Biosens Bioelectron; 2018 Mar; 101():253-259. PubMed ID: 29096363 [TBL] [Abstract][Full Text] [Related]
15. Electrochemical immunosensor for casein based on gold nanoparticles and poly(L-Arginine)/multi-walled carbon nanotubes composite film functionalized interface. Cao Q; Zhao H; Yang Y; He Y; Ding N; Wang J; Wu Z; Xiang K; Wang G Biosens Bioelectron; 2011 Apr; 26(8):3469-74. PubMed ID: 21334187 [TBL] [Abstract][Full Text] [Related]
16. An impedimetric aptasensor for Shigella dysenteriae using a gold nanoparticle-modified glassy carbon electrode. Zarei SS; Soleimanian-Zad S; Ensafi AA Mikrochim Acta; 2018 Nov; 185(12):538. PubMed ID: 30413894 [TBL] [Abstract][Full Text] [Related]
17. A glassy carbon electrode modified with reduced graphene oxide and gold nanoparticles for electrochemical aptasensing of lipopolysaccharides from Escherichia coli bacteria. Pourmadadi M; Shayeh JS; Omidi M; Yazdian F; Alebouyeh M; Tayebi L Mikrochim Acta; 2019 Nov; 186(12):787. PubMed ID: 31732807 [TBL] [Abstract][Full Text] [Related]
18. A novel and label-free immunosensor for bisphenol A using rutin as the redox probe. Huang Y; Li X; Zheng S Talanta; 2016 Nov; 160():241-246. PubMed ID: 27591610 [TBL] [Abstract][Full Text] [Related]
19. Rapid quantitative detection of Brucella melitensis by a label-free impedance immunosensor based on a gold nanoparticle-modified screen-printed carbon electrode. Wu H; Zuo Y; Cui C; Yang W; Ma H; Wang X Sensors (Basel); 2013 Jul; 13(7):8551-63. PubMed ID: 23881126 [TBL] [Abstract][Full Text] [Related]
20. A label-free electrochemical biosensor based on tubulin immobilized on gold nanoparticle/glassy carbon electrode for the determination of vinblastine. Haghshenas E; Madrakian T; Afkhami A; Saify Nabiabad H Anal Bioanal Chem; 2017 Sep; 409(22):5269-5278. PubMed ID: 28667386 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]