These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 32930484)

  • 1. Early detection of ocular abnormalities in a Chinese multicentre neonatal eye screening programme-1-year result.
    Fei P; Liu Z; He L; Li N; Xu L; Zhang M; Zhou Y; Li F; Wang H; Zhang Q; Huang Q; Li Y; Chen S; Guo W; Li Y; Liu Y; Lu J; Wang Y; Zhu X; Wang L; Wang Y; Xian J; Xu Y; Ji X; Liang T; Ren J; Zhang X; Li J; Zhao P
    Acta Ophthalmol; 2021 May; 99(3):e415-e422. PubMed ID: 32930484
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Universal eye screening: perinatal risk factors and ocular abnormalities in 1795 newborns not meeting retinopathy of prematurity criteria.
    Nayak S; Padhi TR; Mettla AL; Khanna RC
    Eye (Lond); 2024 Aug; 38(11):2216-2223. PubMed ID: 38971922
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Findings of perinatal ocular examination performed on 3573, healthy full-term newborns.
    Li LH; Li N; Zhao JY; Fei P; Zhang GM; Mao JB; Rychwalski PJ
    Br J Ophthalmol; 2013 May; 97(5):588-91. PubMed ID: 23426739
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fundus examination of 199 851 newborns by digital imaging in China: a multicentre cross-sectional study.
    Tang H; Li N; Li Z; Zhang M; Wei M; Huang C; Wang J; Li F; Wang H; Liu Z; He L; Cheng Y; Chen W; Jin L; Gong L; Lu J; Xue Y; Su M; Wang Y; Mo H; Chen Z; Guo W; Li Y; Pan H; Zhang W; Ma X; Jin X; Wang B;
    Br J Ophthalmol; 2018 Dec; 102(12):1742-1746. PubMed ID: 30120130
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Universal ocular screening of 481 infants using wide-field digital imaging system.
    Ma Y; Deng G; Ma J; Liu J; Li S; Lu H
    BMC Ophthalmol; 2018 Oct; 18(1):283. PubMed ID: 30376816
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [A pilot study of ocular diseases screening for neonates in China].
    Nie WY; Wu HR; Qi YS; Zhang M; Hou Q; Yang HX; Gong LX; Dong YR; Guo YL; Shi JN; Yin SY; Li PY
    Zhonghua Yan Ke Za Zhi; 2008 Jun; 44(6):497-502. PubMed ID: 19035238
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fundus Examination of 23,861 Newborns by Digital Imaging in Ningbo.
    Liu D; Zheng J; Lu Y
    J Ophthalmol; 2021; 2021():6620412. PubMed ID: 34012681
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Coincidental ocular findings during retinopathy of prematurity telescreening of 9105 neonates.
    Ranjan R; Das A; Prema S; Shah PK; Venkatapathy N
    Eur J Ophthalmol; 2022 Jan; 32(1):563-574. PubMed ID: 33719645
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Retinopathy of prematurity detection: a retrospective quality improvement project before-after implementation of retinal digital imaging for screening.
    Desurmont MG; Bremond-Gignac D; Torchin H; Vacherot B; Jarreau PH; Daruich A
    Eur J Pediatr; 2023 Jul; 182(7):3093-3099. PubMed ID: 37076746
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Red reflex examination in neonates: evaluation of 3 years of screening.
    Cagini C; Tosi G; Stracci F; Rinaldi VE; Verrotti A
    Int Ophthalmol; 2017 Oct; 37(5):1199-1204. PubMed ID: 27822637
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Full-Term Neonatal Ophthalmic Screening in China: A Review of 4-Year Outcomes.
    Li LH; Wu WC; Li N; Lu J; Zhang GM; Zhao JY; Ma Y
    Ophthalmic Surg Lasers Imaging Retina; 2017 Dec; 48(12):983-992. PubMed ID: 29253301
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intraocular Hemorrhages and Retinopathy of Prematurity in the Telemedicine Approaches to Evaluating Acute-Phase Retinopathy of Prematurity (e-ROP) Study.
    Daniel E; Ying GS; Siatkowski RM; Pan W; Smith E; Quinn GE;
    Ophthalmology; 2017 Mar; 124(3):374-381. PubMed ID: 27986386
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Accidentally diagnosed ocular abnormalities identified during close screening for retinopathy of prematurity.
    Ozturk T; Durmaz Engin C; Karatas Yigitaslan E; Yaman A; Berk T
    Eur J Ophthalmol; 2022 Nov; 32(6):3267-3273. PubMed ID: 35261269
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wide-field digital retinal imaging versus binocular indirect ophthalmoscopy for retinopathy of prematurity screening: a two-observer prospective, randomised comparison.
    Dhaliwal C; Wright E; Graham C; McIntosh N; Fleck BW
    Br J Ophthalmol; 2009 Mar; 93(3):355-9. PubMed ID: 19028742
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Outcome of universal newborn eye screening with wide-field digital retinal image acquisition system: a pilot study.
    Goyal P; Padhi TR; Das T; Pradhan L; Sutar S; Butola S; Behera UC; Jain L; Jalali S
    Eye (Lond); 2018 Jan; 32(1):67-73. PubMed ID: 28737759
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Eye disorders in newborn infants (excluding retinopathy of prematurity).
    Wan MJ; VanderVeen DK
    Arch Dis Child Fetal Neonatal Ed; 2015 May; 100(3):F264-9. PubMed ID: 25395469
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Screening for retinopathy of prematurity in China: a neonatal units-based prospective study.
    Xu Y; Zhou X; Zhang Q; Ji X; Zhang Q; Zhu J; Chen C; Zhao P
    Invest Ophthalmol Vis Sci; 2013 Dec; 54(13):8229-36. PubMed ID: 24204053
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Excellent accuracy of trained neonatal nurses in the detection of referral-warranted retinopathy of prematurity within an established telemedicine screening programme.
    Nguyen TAL; Raileanu V; Smith B; Griffin A; Shah S
    J Paediatr Child Health; 2024 Aug; 60(8):369-374. PubMed ID: 39034445
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Analysis of fundus examination results in 8 808 pediatric patients in Northwest China].
    Yan HX; Li MH; Zhang ZF; Wang L; Wu L; Fan J; Zhou Y; Gou KL; Wang YS
    Zhonghua Yan Ke Za Zhi; 2021 Oct; 57(10):777-783. PubMed ID: 34619949
    [No Abstract]   [Full Text] [Related]  

  • 20. Universal ocular screening of 1021 term infants using wide-field digital imaging in a single public hospital in India - a pilot study.
    Vinekar A; Govindaraj I; Jayadev C; Kumar AK; Sharma P; Mangalesh S; Simaldi L; Avadhani K; Shetty B; Bauer N
    Acta Ophthalmol; 2015 Aug; 93(5):e372-e376. PubMed ID: 25721891
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.