BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

271 related articles for article (PubMed ID: 32945089)

  • 1. Polyether ether ketone surface modification with plasma and gelatin for enhancing cell attachment.
    Mehdizadeh Omrani M; Kumar H; Mohamed MGA; Golovin K; S Milani A; Hadjizadeh A; Kim K
    J Biomed Mater Res B Appl Biomater; 2021 May; 109(5):622-629. PubMed ID: 32945089
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of High-Performance Polyether Ether Ketone Polymer Treated with Piranha Solution and Epigallocatechin-3-Gallate Coating.
    Alsmael MA; Al-Khafaji AM
    Biomed Res Int; 2024; 2024():1741539. PubMed ID: 38628498
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surface plasma treatment and phosphorylation enhance the biological performance of poly(ether ether ketone).
    Fukuda N; Tsuchiya A; Sunarso ; Toita R; Tsuru K; Mori Y; Ishikawa K
    Colloids Surf B Biointerfaces; 2019 Jan; 173():36-42. PubMed ID: 30266018
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nano-TiO2/PEEK bioactive composite as a bone substitute material: in vitro and in vivo studies.
    Wu X; Liu X; Wei J; Ma J; Deng F; Wei S
    Int J Nanomedicine; 2012; 7():1215-25. PubMed ID: 22419869
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Osteoblasts exhibit a more differentiated phenotype and increased bone morphogenetic protein production on titanium alloy substrates than on poly-ether-ether-ketone.
    Olivares-Navarrete R; Gittens RA; Schneider JM; Hyzy SL; Haithcock DA; Ullrich PF; Schwartz Z; Boyan BD
    Spine J; 2012 Mar; 12(3):265-72. PubMed ID: 22424980
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Facile Surface Modification Method for Synergistically Enhancing the Biocompatibility and Bioactivity of Poly(ether ether ketone) That Induced Osteodifferentiation.
    Zhu Y; Cao Z; Peng Y; Hu L; Guney T; Tang B
    ACS Appl Mater Interfaces; 2019 Aug; 11(31):27503-27511. PubMed ID: 31291088
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Micro-porous polyetheretherketone implants decorated with BMP-2 via phosphorylated gelatin coating for enhancing cell adhesion and osteogenic differentiation.
    Wu J; Li L; Fu C; Yang F; Jiao Z; Shi X; Ito Y; Wang Z; Liu Q; Zhang P
    Colloids Surf B Biointerfaces; 2018 Sep; 169():233-241. PubMed ID: 29778962
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of Extreme Ultraviolet (EUV) Radiation and EUV Induced, N
    Czwartos J; Budner B; Bartnik A; Wachulak P; Butruk-Raszeja BA; Lech A; Ciach T; Fiedorowicz H
    Int J Mol Sci; 2021 Aug; 22(16):. PubMed ID: 34445159
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multifunctional Surface with Enhanced Angiogenesis for Improving Long-Term Osteogenic Fixation of Poly(ether ether ketone) Implants.
    Dong T; Duan C; Wang S; Gao X; Yang Q; Yang W; Deng Y
    ACS Appl Mater Interfaces; 2020 Apr; 12(13):14971-14982. PubMed ID: 32159330
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Tailoring the biologic responses of 3D printed PEEK medical implants by plasma functionalization.
    Han X; Sharma N; Spintzyk S; Zhou Y; Xu Z; Thieringer FM; Rupp F
    Dent Mater; 2022 Jul; 38(7):1083-1098. PubMed ID: 35562293
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimizing surface characteristics for cell adhesion and proliferation on titanium plasma spray coatings on polyetheretherketone.
    Yoon BJ; Xavier F; Walker BR; Grinberg S; Cammisa FP; Abjornson C
    Spine J; 2016 Oct; 16(10):1238-1243. PubMed ID: 27241209
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Enhancement of surface bioactivity on carbon fiber-reinforced polyether ether ketone via graphene modification.
    Yan JH; Wang CH; Li KW; Zhang Q; Yang M; Di-Wu WL; Yan M; Song Y; Ba JJ; Bi L; Han YS
    Int J Nanomedicine; 2018; 13():3425-3440. PubMed ID: 29942128
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Enhanced osteogenic activity of poly ether ether ketone using calcium plasma immersion ion implantation.
    Lu T; Qian S; Meng F; Ning C; Liu X
    Colloids Surf B Biointerfaces; 2016 Jun; 142():192-198. PubMed ID: 26954085
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Antibacterial activity, bio-compatibility and osteogenic differentiation of graphene oxide coating on 3D-network poly-ether-ether-ketone for orthopaedic implants.
    Guo C; Lu R; Wang X; Chen S
    J Mater Sci Mater Med; 2021 Oct; 32(11):135. PubMed ID: 34704134
    [TBL] [Abstract][Full Text] [Related]  

  • 15. NaOH-etched/boron-doped nanohydroxyapatite-coated PEEK implants enhance the proliferation and differentiation of osteogenic cells.
    Gültan T; Yurtsever MÇ; Gümüşderelioğlu M
    Biomed Mater; 2020 Apr; 15(3):035019. PubMed ID: 32000154
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impaction durability of porous polyether-ether-ketone (PEEK) and titanium-coated PEEK interbody fusion devices.
    Torstrick FB; Klosterhoff BS; Westerlund LE; Foley KT; Gochuico J; Lee CSD; Gall K; Safranski DL
    Spine J; 2018 May; 18(5):857-865. PubMed ID: 29366985
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone.
    Wang H; Xu M; Zhang W; Kwok DT; Jiang J; Wu Z; Chu PK
    Biomaterials; 2010 Nov; 31(32):8181-7. PubMed ID: 20692699
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fabrication and in vitro study of 3D novel porous hydroxyapatite/polyether ether ketone surface nanocomposite.
    Almasi D; Lau WJ; Rasaee S; Abbasi K
    J Biomed Mater Res B Appl Biomater; 2022 Apr; 110(4):838-847. PubMed ID: 34788503
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Characterization of thick titanium plasma spray coatings on PEEK materials used for medical implants and the influence on the mechanical properties.
    Vogel D; Dempwolf H; Baumann A; Bader R
    J Mech Behav Biomed Mater; 2018 Jan; 77():600-608. PubMed ID: 29096126
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Material characterization and Streptococcus oralis adhesion on Polyetheretherketone (PEEK) and titanium surfaces used in implantology.
    D'Ercole S; Cellini L; Pilato S; Di Lodovico S; Iezzi G; Piattelli A; Petrini M
    J Mater Sci Mater Med; 2020 Sep; 31(10):84. PubMed ID: 32989624
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.