These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 3295885)

  • 1. Comparison of E. coli endotoxin 055:B5 with U.S. Standard Endotoxin EC-5 using the Limulus amebocyte lysate assay.
    Hochstein HD; Rivera ES; Outschoorn AS
    Prog Clin Biol Res; 1987; 231():133-41. PubMed ID: 3295885
    [No Abstract]   [Full Text] [Related]  

  • 2. The preparation of a control standard endotoxin to be used in both the gel-clot and chromogenic Limulus amebocyte lysate test.
    Berzofsky RN
    Prog Clin Biol Res; 1987; 231():183-8. PubMed ID: 3588616
    [No Abstract]   [Full Text] [Related]  

  • 3. Statistical procedure for standardizing control standard endotoxin against U.S. reference standard endotoxin using Limulus amebocyte lysate test.
    Rastogi SC
    Prog Clin Biol Res; 1982; 93():49-54. PubMed ID: 7122604
    [No Abstract]   [Full Text] [Related]  

  • 4. U.S. Government quality control program for Limulus amebocyte lysate and endotoxin.
    Hochstein HD
    Prog Clin Biol Res; 1985; 189():221-39. PubMed ID: 4048206
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of several control standard endotoxins to the National Reference Standard Endotoxin--an HIMA collaborative study.
    Pearson FC; Weary ME; Sargent HE; Novitsky TJ; Lin H; Lindsay G; Berzofsky RN; Lane AL; Wilson JD; Cooper JF
    Appl Environ Microbiol; 1985 Jul; 50(1):91-3. PubMed ID: 3896144
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A modified Limulus amebocyte lysate test with increased sensitivity for detection of bacterial endotoxin.
    Roth RI; Levin J; Behr S
    J Lab Clin Med; 1989 Sep; 114(3):306-11. PubMed ID: 2671216
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Collaborative study of a control standard endotoxin using the Limulus amebocyte (gel-clot) test.
    Adner N; Flink O; Nystrand R; Pihl B; Vegis P
    J Parenter Sci Technol; 1991; 45(2):88-93. PubMed ID: 2051262
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The importance of the quality of water in Limulus Amebocyte Lysate tests.
    Dunér KI
    PDA J Pharm Sci Technol; 1995; 49(3):119-21. PubMed ID: 7613989
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Destruction of typical endotoxins by dry heat as determined using LAL assay and pyrogen assay.
    Nakata T
    J Parenter Sci Technol; 1993; 47(5):258-64. PubMed ID: 8263663
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Review of the Bureau of Biologic's experience with Limulus amebocyte lysate and endotoxin.
    Hochstein HD
    Prog Clin Biol Res; 1982; 93():141-51. PubMed ID: 7122587
    [No Abstract]   [Full Text] [Related]  

  • 11. Endotoxins and their detection with the Limulus amebocyte lysate test. Proceedings of an International Conference on Endotoxin Standards and Limulus Amebocyte Lysate Use with Parenteral Drugs, Woods Hole, Massachusetts, September 1981.
    Prog Clin Biol Res; 1982; 93():1-417. PubMed ID: 7122583
    [No Abstract]   [Full Text] [Related]  

  • 12. Pyrogenicity of E. coli 055:b5 endotoxin by the USP rabbit test--a HIMA collaborative study.
    Dabbah R; Ferry E; Gunther DA; Hahn R; Mazur P; Neely M; Nicholas P; Pierce JS; Slade J; Watson S; Weary M; Sanford RL
    J Parenter Drug Assoc; 1980; 34(3):212-6. PubMed ID: 6995571
    [No Abstract]   [Full Text] [Related]  

  • 13. [Detection of endotoxins in radiopharmaceutical preparations--II. Comparison of the sensitivity of methods using the rabbit and the Limulus amoebocyte lysate for the detection of endotoxins].
    Bruneau J; Cohen Y; Merlin L; Peysson S
    Int J Nucl Med Biol; 1986; 12(6):471-6. PubMed ID: 3519489
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Proteinase K digestion of proteins improves detection of bacterial endotoxins by the Limulus amebocyte lysate assay: application for endotoxin removal from cationic proteins.
    Petsch D; Deckwer WD; Anspach FB
    Anal Biochem; 1998 May; 259(1):42-7. PubMed ID: 9606141
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effect of refrigeration and mixing on detection of endotoxin in parenteral drugs using the Limulus Amebocyte Lysate (LAL) test.
    Guilfoyle DE; Yager JF; Carito SL
    J Parenter Sci Technol; 1989; 43(4):183-7. PubMed ID: 2769526
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Heat extraction of animal plasma in preparation for endotoxin testing with the limulus amebocyte lysate test.
    Berg JN; Nausley CA; Riegle L
    Am J Vet Res; 1979 Jul; 40(7):1048-9. PubMed ID: 389112
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Specific assay for endotoxin using immobilized histidine and Limulus amebocyte lysate.
    Minobe S; Nawata M; Watanabe T; Sato T; Tosa T
    Anal Biochem; 1991 Nov; 198(2):292-7. PubMed ID: 1799213
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Structural requirements for gelation of the Limulus amebocyte lysate by endotoxin.
    Morrison DC; Vukajlovich SW; Ryan JL; Levin J
    Prog Clin Biol Res; 1987; 231():55-73. PubMed ID: 3295889
    [No Abstract]   [Full Text] [Related]  

  • 19. Relative potencies of four reference endotoxin standards as measured by the Limulus amoebocyte lysate and USP rabbit pyrogen tests.
    Weary ME; Donohue G; Pearson FC; Story K
    Appl Environ Microbiol; 1980 Dec; 40(6):1148-51. PubMed ID: 7006505
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The processing and collaborative assay of a reference endotoxin.
    Hochstein HD; Mills DF; Outschoorn AS; Rastogi SC
    J Biol Stand; 1983 Oct; 11(4):251-60. PubMed ID: 6358226
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.