  • 1. Standardized fractal bench test evaluation of coronary stents: Performances in bifurcation lesions treated by the re-proximal optimization technique.
    Piriou PG; Bonin M; Huchet F; Letocart V; Manigold T; Plessis J; Derimay F; Veziers J; Jordana F; Guerin P
    Catheter Cardiovasc Interv; 2021 Jul; 98(1):E9-E17. PubMed ID: 32966675
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sequential Proximal Optimizing Technique in Provisional Bifurcation Stenting With Everolimus-Eluting Bioresorbable Vascular Scaffold: Fractal Coronary Bifurcation Bench for Comparative Test Between Absorb and XIENCE Xpedition.
    Derimay F; Souteyrand G; Motreff P; Guerin P; Pilet P; Ohayon J; Darremont O; Rioufol G; Finet G
    JACC Cardiovasc Interv; 2016 Jul; 9(13):1397-406. PubMed ID: 27388830
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impact of Coronary Stent Design in Proximal Balloon Edge Dilation Technique for Bifurcation Percutaneous Coronary Intervention.
    Kume T; Koto S; Murasato Y; Yamada R; Koyama T; Tamada T; Imai K; Okamoto H; Sudo Y; Enzan A; Neishi Y; Uemura S
    Int Heart J; 2021 Sep; 62(5):1106-1111. PubMed ID: 34544984
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative Analysis of Sequential Proximal Optimizing Technique Versus Kissing Balloon Inflation Technique in Provisional Bifurcation Stenting: Fractal Coronary Bifurcation Bench Test.
    Finet G; Derimay F; Motreff P; Guerin P; Pilet P; Ohayon J; Darremont O; Rioufol G
    JACC Cardiovasc Interv; 2015 Aug; 8(10):1308-1317. PubMed ID: 26315733
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Coronary bifurcation bench test using multimodality imaging: Impact of stent strut link location on stent deformity and jailed side-branch orifices during re-proximal optimizing technique.
    Kume T; Yamada R; Koyama T; Tamada T; Imai K; Fukuhara K; Goryo Y; Kawamura A; Okamoto H; Neishi Y; Uemura S
    Catheter Cardiovasc Interv; 2019 Jan; 93(1):E17-E23. PubMed ID: 30244506
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Influence of platform design of six different drug-eluting stents in provisional coronary bifurcation stenting by rePOT sequence: a comparative bench analysis.
    Derimay F; Souteyrand G; Motreff P; Rioufol G; Finet G
    EuroIntervention; 2017 Oct; 13(9):e1092-e1095. PubMed ID: 28485275
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of Side-Branch Dilation Techniques After Resorbable Magnesium Scaffold Implantation: A Bench Study.
    de Pommereau A; Mogi S; de Hemptinne Q; Adjedj J; Varenne O; Picard F
    J Invasive Cardiol; 2019 Aug; 31(8):E249-E255. PubMed ID: 31368896
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of proximal balloon edge dilation technique for opening a side branch ostium in repetitive-proximal optimizing technique sequence.
    Kume T; Murasato Y; Yamada R; Koyama T; Tamada T; Imai K; Okamoto H; Enzan A; Neishi Y; Uemura S
    Catheter Cardiovasc Interv; 2021 Jan; 97(1):E12-E18. PubMed ID: 32329140
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Final proximal post-dilatation is necessary after kissing balloon in bifurcation stenting.
    Foin N; Secco GG; Ghilencea L; Krams R; Di Mario C
    EuroIntervention; 2011 Sep; 7(5):597-604. PubMed ID: 21930464
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Simple versus complex approaches to treating coronary bifurcation lesions: direct assessment of stent strut apposition by optical coherence tomography.
    Tyczynski P; Ferrante G; Moreno-Ambroj C; Kukreja N; Barlis P; Pieri E; De Silva R; Beatt K; Di Mario C
    Rev Esp Cardiol; 2010 Aug; 63(8):904-14. PubMed ID: 20738935
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Benefit of a new provisional stenting strategy, the re-proximal optimisation technique: the rePOT clinical study.
    Dérimay F; Finet G; Souteyrand G; Maillard L; Aminian A; Lattuca B; Cayla G; Cellier G; Motreff P; Rioufol G
    EuroIntervention; 2018 Jun; 14(3):e325-e332. PubMed ID: 29553940
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Benefits of final proximal optimization technique (POT) in provisional stenting.
    Dérimay F; Rioufol G; Cellier G; Souteyrand G; Finet G
    Int J Cardiol; 2019 Jan; 274():71-73. PubMed ID: 30236500
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Efficacy of the proximal optimization technique on crossover stenting in coronary bifurcation lesions in the 3D-OCT bifurcation registry.
    Murasato Y; Mori T; Okamura T; Nagoshi R; Fujimura T; Yamawaki M; Ono S; Serikawa T; Nakao F; Shite J;
    Int J Cardiovasc Imaging; 2019 Jun; 35(6):981-990. PubMed ID: 30887408
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mini- versus classical kissing balloon inflation in provisional technique for bifurcation intervention.
    Liu J; Chen S; Wei J; Zeng F; Li L
    J Interv Cardiol; 2018 Dec; 31(6):755-764. PubMed ID: 30069984
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Healing responses after bifurcation stenting with the dedicated TRYTON Side-Branch Stent™ in combination with XIENCE-V™ stents: a clinical, angiography, fractional flow reserve, and optical coherence tomography study: the PYTON (Prospective evaluation of the TRYTON Side-Branch Stent™ with an additional XIENCE-v™ everolimus-eluting stent in coronary bifurcation lesions) study.
    Dubois C; Adriaenssens T; Ughi G; Wiyono S; Bennett J; Coosemans M; Ferdinande B; Sinnaeve P; D'hooge J; Desmet W
    Catheter Cardiovasc Interv; 2013 Feb; 81(3):E155-64. PubMed ID: 22745031
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Classification of mechanisms of strut malapposition after angiographically optimized stent implantation: An optical coherence tomography study.
    Agrawal M; Hakeem A; Ahmed Z; Uretsky BF
    Catheter Cardiovasc Interv; 2017 Aug; 90(2):225-232. PubMed ID: 28805036
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation.
    Kim BK; Shin DH; Kim JS; Ko YG; Choi D; Jang Y; Hong MK
    Int J Cardiovasc Imaging; 2012 Dec; 28(8):1887-94. PubMed ID: 22447206
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sequential coronary bifurcation revascularization with the Xposition S™ self-apposing stent: a comparative fractal bench study.
    Dérimay F; Maillard L; Rioufol G; Souteyrand G; Aminian A; Veziers J; Guerin P; Finet G
    Heart Vessels; 2020 Jan; 35(1):132-135. PubMed ID: 31250129
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model.
    Hikichi Y; Umezu M; Node K; Iwasaki K
    Cardiovasc Interv Ther; 2017 Jan; 32(1):12-17. PubMed ID: 26968169
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optical coherence tomography (OCT) strut-level analysis of drug-eluting stents (DES) in human coronary bifurcations.
    Kyono H; Guagliumi G; Sirbu V; Rosenthal N; Tahara S; Musumeci G; Trivisonno A; Bezerra HG; Costa MA
    EuroIntervention; 2010 May; 6(1):69-77. PubMed ID: 20542800
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.