BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

393 related articles for article (PubMed ID: 32972726)

  • 1. Biomechanical analysis of peri‑implant fractures in short versus long cephalomedullary implants following pertrochanteric fracture consolidation.
    Breceda A; Sands A; Zderic I; Schopper C; Schader J; Gehweiler D; Mischler D; Richards G; Gueorguiev B
    Injury; 2021 Jan; 52(1):60-65. PubMed ID: 32972726
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical evaluation of the risk of secondary fracture around short versus long cephalomedullary nails.
    Daner WE; Owen JR; Wayne JS; Graves RB; Willis MC
    Eur J Orthop Surg Traumatol; 2017 Dec; 27(8):1103-1108. PubMed ID: 28597401
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Distal locking of short cephalomedullary nails decreases varus collapse in unstable intertrochanteric fractures - a biomechanical analysis.
    Tisherman RT; Hankins ML; Moloney GB; Tarkin IS
    Injury; 2021 Mar; 52(3):414-418. PubMed ID: 33593524
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of long, short, and extended-short nail construct for femoral intertrochanteric fractures.
    Marmor M; Elliott IS; Marshall ST; Yacoubian SV; Yacoubian SV; Herfat ST
    Injury; 2015; 46(6):963-9. PubMed ID: 25818058
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of distal interlocking of a cephalomedullary femoral nail on peri-implant fractures: A sawbone biomechanical analysis.
    Saggi SS; Chou SM; Wong HPN; Wong MK; Bin Abd Razak HR
    Injury; 2022 Dec; 53(12):3894-3898. PubMed ID: 36229244
    [TBL] [Abstract][Full Text] [Related]  

  • 6. How are peri-implant fractures below short versus long cephalomedullary nails different?
    Goodnough LH; Salazar BP; Furness J; Feng JE; DeBaun MR; Campbell ST; Lucas JF; Cross WW; Leucht P; Grant KD; Gardner MJ; Bishop JA
    Eur J Orthop Surg Traumatol; 2021 Apr; 31(3):421-427. PubMed ID: 32909108
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimizing fixation methods for stable and unstable intertrochanteric hip fractures treated with sliding hip screw or cephalomedullary nailing: A comparative biomechanical and finite element analysis study.
    Kyriakopoulos G; Panagopoulos A; Pasiou E; Kourkoulis SK; Diamantakos I; Anastopoulos G; Tserpes K; Tatani I; Lakoumentas J; Megas P
    Injury; 2022 Dec; 53(12):4072-4085. PubMed ID: 36272844
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Outcomes after unstable pertrochanteric femur fracture: intermediate versus long cephalomedullary nails.
    Thamyongkit S; MacKenzie JS; Sirisreetreerux N; Shafiq B; Hasenboehler EA
    Eur J Trauma Emerg Surg; 2020 Oct; 46(5):963-968. PubMed ID: 30143808
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical analysis of recently released cephalomedullary nails for trochanteric femoral fracture fixation in a human cadaveric model.
    Pastor T; Zderic I; Gehweiler D; Gardner MJ; Stoffel K; Richards G; Knobe M; Gueorguiev B
    Arch Orthop Trauma Surg; 2022 Dec; 142(12):3787-3796. PubMed ID: 34748055
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Risk of shortening in operatively treated proximal femur fractures with cephalomedullary nails with dynamically versus statistically locked helical blades.
    Cherian N; Oladeji L; Ohnoutka C; Touhey D; Sauer M; Schweser KA; Kfuri M; Cook JL; Rocca GJD; Crist BD
    Injury; 2023 Feb; 54(2):669-676. PubMed ID: 36539309
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Is distal locking necessary? A biomechanical investigation of intramedullary nailing constructs for intertrochanteric fractures.
    Gallagher D; Adams B; El-Gendi H; Patel A; Grossman L; Berdia J; Korshunov Y; Goldman A
    J Orthop Trauma; 2013 Jul; 27(7):373-8. PubMed ID: 23249889
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A biomechanical comparison of locked and unlocked long cephalomedullary nails in a stable intertrochanteric fracture model.
    Kane P; Vopat B; Paller D; Koruprolu S; Daniels AH; Born C
    J Orthop Trauma; 2014 Dec; 28(12):715-20. PubMed ID: 24978941
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Quality differences in multifragmentary pertrochanteric fractures [OTA 31A2.2 and 31A2.3] treated with short and long cephalomedullary nails.
    Parola R; Maseda M; Herbosa CG; Konda SR; Ganta A; Egol KA
    Injury; 2022 Jul; 53(7):2600-2604. PubMed ID: 35643558
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Distal locking in short hip nails: Cause or prevention of peri-implant fractures?
    Skála-Rosenbaum J; Džupa V; Bartoška R; Douša P; Waldauf P; Krbec M
    Injury; 2016 Apr; 47(4):887-92. PubMed ID: 26961434
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Setscrew distal locking for intramedullary nails: a biomechanical study.
    Köse N; Günal I; Wang X; Athanasiou KA; Agrawal CM; Mabrey JD
    J Orthop Trauma; 2000 Aug; 14(6):414-9. PubMed ID: 11001415
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical Analysis of Retrograde Flexible Intramedullary Nail Constructs in a Simulated Pediatric Femur Fracture Model.
    Bland DC; Black SR; Pierce WA; Wimberly RL; Riccio AI
    J Pediatr Orthop; 2019 Jan; 39(1):22-27. PubMed ID: 28141692
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Progress on distal interlocking screw of cephalomedullary nail for intertrochanteric fractures].
    Li Q; Zhang S
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Sep; 28(9):1177-80. PubMed ID: 25509788
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Internal fixation of type-C distal femoral fractures in osteoporotic bone.
    Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO; Mückley T
    J Bone Joint Surg Am; 2010 Jun; 92(6):1442-52. PubMed ID: 20516320
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The early failure of the gamma nail and the dynamic hip screw in femurs with a wide medullary canal. A biomechanical study of intertrochanteric fractures.
    Ceynowa M; Zerdzicki K; Klosowski P; Pankowski R; Rocławski M; Mazurek T
    Clin Biomech (Bristol, Avon); 2020 Jan; 71():201-207. PubMed ID: 31775090
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical evaluation of retrograde docking nailing to a total hip arthroplasty stem in a periprosthetic femur fracture model.
    Lenz M; Hofmann-Fliri L; Kasper LA; Varga P; Zderic I; Gehweiler D; Klos K; Hofmann GO; Stoffel K; Gueorguiev B
    Injury; 2021 Jan; 52(1):53-59. PubMed ID: 33129493
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.